MacArthur, D.W.
Los Alamos National Lab., NM (USA)1987
Los Alamos National Lab., NM (USA)1987
AbstractAbstract
[en] We discuss the design and specifications of a 10-in. x 10-in. active area wire chamber. Several of these chambers will be combined with polyethylene converters to make a large volume detector intended for use as a high-energy detector displaying moderate energy resolution. We also discuss the amplifiers and discriminators that have been designed for these chambers. This report only concerns the wire chambers and electronics
Secondary Subject
Source
Feb 1987; 26 p; Available from NTIS, PC A03/MF A01; 1 as DE87006318; Portions of this document are illegible in microfiche products. Original copy available until stock is exhausted.
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Original Title
Un nouveau piege pour les particules
Record Type
Journal Article
Journal
Sciences et Avenir; (no.311); p. 54-59
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The Mesh Chamber is designed to be highly efficient for the conversion of high energy gamma rays and to measure the conversion point with good spatial resolution. It utilizes a multiwire proportional chamber (MWPC) detector which measures the x-y position of the ionization from the gamma conversion electron in the chamber gas. The gas itself is of insufficient density to provide enough conversion material. The special idea in this chamber is to fill the gas volume with many layers of Tungsten wire screen all precisely laid down so that the holes in the screen are aligned. This report covers a new development where x-y plotter is modified so that the pen holder becomes a wire feed. The plotter is controlled by a computer. 4 figs
Primary Subject
Source
1979; 4 p; Available from NTIS, PC A02/MF A01; 1 as DE86011572; Portions of this document are illegible in microfiche products.
Record Type
Report
Literature Type
Progress Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Source
13. scintillation and semiconductor counter symposium; Washington, DC; 1 Mar 1972
Record Type
Journal Article
Literature Type
Conference
Journal
IEEE (Inst. Elec. Electron. Eng.), Trans. Nucl. Sci; v. NS-19(3); p. 152-157
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Service de l'Accelerateur Lineaire; CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Service de Physique Nucleaire a Haute Energie
Progress report. 1 October 1972-30 September 1973
Progress report. 1 October 1972-30 September 1973
AbstractAbstract
No abstract available
Original Title
Detection pour les aimants 600 et 900 de la salle HE1; multiwire proportional chambers
Source
CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Dept. de Physique Nucleaire; p. 204-212; nd
Record Type
Report
Literature Type
Progress Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Filippov, A.I.; Fursov, A.P.; Korenchenko, A.S.; Korenchenko, S.M.; Kravchuk, N.P.; Nekrasov, K.G.; Vanko, J.
Low radioactivities '85. (The 7th Nuclear Science Colloquium)1985
Low radioactivities '85. (The 7th Nuclear Science Colloquium)1985
AbstractAbstract
No abstract available
Source
Komenskeho Univ., Bratislava (Czechoslovakia). Matematicko-Fyzikalna Fakulta; 147 p; 1985; p. VI/25; 3. international conference on low-level counting ''Low Radioactivities '85''; Bratislava (Czechoslovakia); 21-25 Oct 1985; Published in summary form only.
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Second coordinate readout in MWPC by means of sensing electrodes made up by interwoven grid wires has been tested. The results are compared with theoretical expectation. The tapered electrodes tested allow the number of sensing outputs to be reduced and provide signals useful for a quasi-linear interpolation. (orig.)
Record Type
Journal Article
Journal
Nuclear Instruments and Methods; ISSN 0029-554X; ; v. 167(3); p. 417-422
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Ahmad, S.; Bizot, J.C.; Delcourt, B.; Jeanjean, J.; Jeanjean, M.; Nguyen-Ngoc, H.; Wodrich, W.R.
Paris-11 Univ., 91 - Orsay (France). Lab. de l'Accelerateur Lineaire1983
Paris-11 Univ., 91 - Orsay (France). Lab. de l'Accelerateur Lineaire1983
AbstractAbstract
[en] We describe the construction and the performance of large cylindrical multiwire proportional chambers (roughly 2 meters in diameter and 1 meter long) with anode read out system. The inner and the outer cathode planes are made of foil and foam sandwiches. At 100% efficiency average anode plateau widths of about 300 volts are obtained
Source
Jan 1983; 10 p
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Hubbard, J.R.; Coutrakon, G.; Cribier, M.; Mangeot, P.; Martin, H.; Mullie, J.; Palanque, S.; Pelle, J.
CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Service des Techniques Instrumentales1980
CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Service des Techniques Instrumentales1980
AbstractAbstract
[en] Physical processes in multi-step avalanche chambers, detector properties, and difficulties in operation are discussed. Advantages of multi-step chambers over classical MWPC for specific experimental problems encountered in experiment E605 (high-flux environment and CERENKOV imaging) are described. Some details of detector design are presented
Source
Feb 1980; 18 p; Wire chamber conference; Vienna, Austria; 27 - 29 Feb 1980
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Source
Komenskeho Univ., Bratislava (Czechoslovakia); 114 p; 1983; p. III/15; 11. international symposium on nuclear electronics; Bratislava (Czechoslovakia); 6-12 Sep 1983; Published in summary form only.
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
Related RecordRelated Record