Schweiger, F.; Wohler, J.
Hochtemperatur-Kernkraftwerk G.m.b.H. (HKG), Uentrop (Germany, F.R.)1977
Hochtemperatur-Kernkraftwerk G.m.b.H. (HKG), Uentrop (Germany, F.R.)1977
AbstractAbstract
[en] This process is designed to avoid the tedious shutting down and starting up of an HTR with its high heat stresses if faults require shutting off but not reduction to the cold subcritical condition. In such cases a period of shutdown with removal of criticality but maintaining relatively high temperature is sufficient. For this purpose, the reactivity is reduced by only 0.5%, by suitably driving in the absorber rods. Then the reactor is kept in the subcritical condition by circulation of coolant at operating temperature. With the negative reactivity - temperature coefficient there is an inherently safe shutdown condition. (HP)
[de]
Dieses Verfahren will das langwierige Ab- und Wiederanfahren eines HTGR mit seinen hohen Wechselwaermebeanspruchungen dann vermeiden, wenn einfache Stoerfaelle zwar ein Abschalten, aber nicht das Herunterfahren bis in den kaltunterkritischen Zustand verlangen. In solchen Faellen genuegt ein zeitweiliges Abschalten unter Aufheben der Kritikalitaet, aber Aufrechterhaltung relativ hoher Temperatur. Hierzu wird zunaechst die Reaktivitaet um nur 0,5% verringert mittels entsprechend eingefahrener Absorberstaebe. Dann wird der Reaktor durch Verminderung der Kuehlmittelzufuhr auf Betriebstemperatur im unterkritischen Zustand gehalten. Mit dem negativen Temperaturkoeffizienten der Reaktivitaet ergibt sich ein inhaerent sicherer Abschaltzustand. (HP)Original Title
Verfahren zum zeitweiligen Abschalten eines Hochtemperatur-Kernreaktors
Primary Subject
Source
18 Aug 1977; 1 p; DE PATENT DOCUMENT 2265032/C/; Also available from Dt. Patentamt, Muenchen (FRG)
Record Type
Patent
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Noyes, R.C.; Zaman, S.U.; Stuteville, D.W.
Combustion Engineering, Inc., Windsor, CT (USA)1980
Combustion Engineering, Inc., Windsor, CT (USA)1980
AbstractAbstract
[en] In a guide tube of the liquid metal-cooled (Na) reactor a number of absorber rods containing B C is arranged. If the coolant flow rate becomes too low the rods are dropped into the reactor core. For this purpose a chamber with a bellows wall serves as safety and tripping element. The chamber is mechanically connected with the absorber rods. The gas contained in the chamber keeps the bellows and with it the absorber rods in a fixed position until the coolant pressure is decreasing. Then the bellows will move the absorber rods in the direction of the reactor core. (orig.)
Original Title
Vorrichtung zum Betaetigen der Notabschaltung eines Kernreaktors
Primary Subject
Source
13 Nov 1980; 4 p; DE PATENT DOCUMENT 2831028/C/; Available from Deutsches Patentamt, Muenchen, Germany, F.R
Record Type
Patent
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Original Title
Malfunction of a microswitch
Primary Subject
Secondary Subject
Source
11 Sep 1973; 1 p
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Schmidt, I.; Adams, J.
Kernkraftwerk Lingen GmbH (Germany, F.R.)1989
Kernkraftwerk Lingen GmbH (Germany, F.R.)1989
AbstractAbstract
[en] The company's essential task consists in the management of the decommissioning program including the later demolition of the nuclear power plant of Lingen. The company's activities in 1988 are reported on. (UA)
[de]
Wesentliche Aufgabe der Gesellschaft besteht in der Abwicklung des Stillegungsprogramms einschliesslich des spaeteren Abbruchs des Kernkraftwerks Lingen. Es wird ueber die Aktivitaeten der Gesellschaft in 1988 berichtet. (UA)Original Title
KWL Bericht ueber das Geschaeftsjahr 1988
Primary Subject
Source
1989; 22 p
Record Type
Miscellaneous
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] An attempt is made to construct sufficient conditions for xenon and temperature-controlled nuclear reactors to be stable against power excursions or inadvertent shutdowns. Region of asymptotic stability in the large in the plane of equilibrium flux versus temperature coefficient is determined. Two different criteria for the region asymptotic stability are compared. (author)
Primary Subject
Record Type
Journal Article
Journal
Turkish Journal of Nuclear Sciences; v. 10(1); p. 3-12
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Asay, R.H.
Electric Power Research Inst., Palo Alto, CA (United States); Radiological and Chemical Technology, Inc., Santa Clara, CA (United States). Funding organisation: Electric Power Research Inst., Palo Alto, CA (United States)1993
Electric Power Research Inst., Palo Alto, CA (United States); Radiological and Chemical Technology, Inc., Santa Clara, CA (United States). Funding organisation: Electric Power Research Inst., Palo Alto, CA (United States)1993
AbstractAbstract
[en] Large releases of activated corrosion products from the fuel surfaces (or other core internals) during shutdowns may lead to increased out-of-core radiation levels. Controlled shutdown methods to minimize boiling and maximize cleanup have been tried to reduce the impact of released activated corrosion products on radiation levels. A survey of BWR reactors was made and the data reviewed to determine possible benefits of controlling the plant shutdown process. Both routine and controlled shutdown data was made available for about one-third of the BWR's in the United States
Primary Subject
Source
Dec 1993; 109 p; Available from EPRI Distribution Center, 207 Coggins Drive, PO Box 23205, Pleasant Hill, CA 94523
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Original Title
Failure of emergency diesels to start during routine surveillance testing
Primary Subject
Secondary Subject
Source
18 Jul 1973; 4 p
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] This report shows tables with information on (1) number of shutdowns by reactor type and percent power at time of shutdown, (2) the number of shutdowns by reactor type and by shutdown type, and (3) the number of shutdowns by reactor type and age
Primary Subject
Record Type
Journal Article
Literature Type
Numerical Data
Journal
Nuclear Safety; ISSN 0029-5604; ; v. 25(5); p. 704-705
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Short communication
Original Title
Ausstieg vom Ausstieg? In Schweden ist die Atomstrom-Diskussion neu entflammt
Primary Subject
Secondary Subject
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Primary Subject
Source
Short note.
Record Type
Journal Article
Journal
Archimedes; ISSN 0003-8385; ; v. 23(3); p. 38
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
1 | 2 | 3 | Next |