AbstractAbstract
[en] All the non interacting monitors used for the p-anti p instrumentation can be related to the use of the wall image current as induced by relativistic charged particle bunches circulating in a metallic pipe or vacuum chamber. The monitors are then classified by their type of beam coupling impedance. This allows a more generalized approach of the design of the so-called pickups. (orig./HSI)
Source
Bryant, P.; Newman, S. (eds.); European Organization for Nuclear Research, Geneva (Switzerland); 562 p; 20 Dec 1984; p. 385-467; CERN accelerator school on antiprotons for colliding beam facilities; Geneva (Switzerland); 11-21 Oct 1983
Record Type
Report
Literature Type
Conference; Progress Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue