Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.024 seconds
AbstractAbstract
[en] Full text: Objective: To evaluate the utility of 99mTc-HMPAO labeled leucocyte, 99mTc-labeled anti-granulocyte antibody and 67Ga scintigraphy in patients suspected to have infected hip and knee replacements, from March/1998 to March/ 2002. Methods: Retrospective study of 33 patients (12 male, 21 female) with an average age of 61,1 ± 7,3 years. Nineteen had hip replacements and 14 were submitted to knee replacements. 99mTc-HMPAO labeled leucocyte scintigraphy was performed in 17 patients, 99mTc-labeled anti-granulocyte antibody scintigraphy in 13 patients and 67Ga scintigraphy in 3 patients. Twenty-six patients were also submitted to 3-phase 99mTc-MDP bone scintigraphy. Results were compared to those from studies with infection/inflammation agents. Concordant positive studies were considered to be a positive result for infection. A second study using 67Ga was also performed in 3 patients. Results: Diagnosis was based on surgical findings in 14 patients, pathologic study of biopsy specimen in 1 case and clinical/ imaging follow-up in 18 patients. Infection was detected in 22 cases and absent in 11. The conjoined evaluation of scintigraphic studies considered infection to be present in 20 cases and absent in 13. With infection/inflammation agents, 20 cases were positive (+) and 13 cases were negative (-). Using 99mTc-HMPAO labeled leucocytes, 12 cases were (+) and 5 cases were (-). With 99mTc-labeled anti-granulocyte antibodies, 8 cases were (+) and 5 were (-). With 67Ga, all 3 cases were (-). In patients with (+) studies using infection/ inflammation agents, a false positive case with 99mTc-HMPAO labeled leucocytes was reported. Two false negative cases were detected, both with 99mTc-labeled antigranulocyte antibodies, in patients with (-) studies. Regarding the studies with 99mTc-MDP, 24 were (+) and 2 were (-). Eighteen of these (+) cases were also (+) in studies with infection/inflammation agents, but 6 were (-) with these agents. Negative cases were also (-) in studies with infection/inflammation agents. Conclusions: Scintigraphy with infection/ inflammation agents yielded a sensitivity of 91%, a specificity of 92%, a PPV of 95%, a NPV of 85% and a diagnostic accuracy of 85%. Bone scintigraphy yielded sensitivity, specificity, PPV and NPV values of 100%, 56%, 50% and 100%, respectively. (author)
Primary Subject
Source
11. international meeting of the International Society of Radiolabelled Blood Elements (ISORBE); Coimbra (Portugal); 11-12 Apr 2003; 9. HUC - Nuclear Medicine Meeting; Coimbra (Portugal); 11-12 Apr 2003; Also available online: www.wjnm.org; Abstract only
Record Type
Journal Article
Literature Type
Conference
Journal
World Journal of Nuclear Medicine; ISSN 1450-1147; ; v. 2(2); p. 149
Country of publication
BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, BODY, COUNTING TECHNIQUES, DAYS LIVING RADIOISOTOPES, DIAGNOSTIC TECHNIQUES, DISEASES, DRUGS, ELECTRON CAPTURE RADIOISOTOPES, GALLIUM ISOTOPES, HOURS LIVING RADIOISOTOPES, INTERMEDIATE MASS NUCLEI, INTERNAL CONVERSION RADIOISOTOPES, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, LABELLED COMPOUNDS, MATERIALS, MEDICAL SUPPLIES, NUCLEI, ODD-EVEN NUCLEI, ORGANS, RADIOACTIVE MATERIALS, RADIOISOTOPE SCANNING, RADIOISOTOPES, SKELETON, TECHNETIUM ISOTOPES, YEARS LIVING RADIOISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue