Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.023 seconds
AbstractAbstract
[en] The study described in this report1 models the FXR injector from the cathode to the exit of the injector. The calculations are compared to actual experimental measurements, table 1. In these measurements the anode voltage was varied by changing the Marks-Bank charging voltage. The anode-cathode spacing was varied by adjusting the location of the cathode in hopes of finding an island of minimum emittance (none found). The bucking coil current was set for zero field on the cathode. In these measurements, a pepper-pot mask was inserted into FXR at beam bug 135 and viewed downstream via a wiggle probe diagnostic at cell gap J21, figure 1. The observed expansion of the beamlets passing through the mask of known geometric layout and hole size allow a calculation of the phase space beam properties
Primary Subject
Source
26 Mar 2004; 3 Megabytes; W-7405-ENG-48; Available from PURL: https://www.osti.gov/servlets/purl/15009822-H3i0Dv/native/; PDF-FILE: 101
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue