AbstractAbstract
[en] The ex-core NIS(Nuclear Instrumentation System) provides a wide range signal and a narrow range signal. Through preamplifier/filter, discriminator circuit, Logarithmic Count Rate(LCR) circuit, MSV(Mean Square Voltage) circuit, and combination circuit, the wide range power signal is generated to represent the actual power level 2x10-8% to 200% power. In this paper, the digitalized wide range signal processing procedure of an ex-core NIS of an Integral Reactor is presented
Primary Subject
Source
Korean Nuclear Society, Taejon (Korea, Republic of); [1 CD-ROM]; 2005; [2 p.]; 2005 spring meeting of the KNS; Jeju (Korea, Republic of); 26-27 May 2005; Available from KNS, Taejon (KR); 3 refs, 3 figs