AbstractAbstract
[en] Paper describes both the procedure and the results of the efforts to test the WWER-1000 fuel assembly 19-component cluster in the MIR reactor channel under the second and the third stages of the maximum design-basis accident. The experiment aim was to the study the reactor core conditions resulting from the uncompensated primary coolant leakage in case of the major pipe break (major break). In any of the studied cases the top of the fuel elements was cooled by the superheated steam. The test aim was to acquire data on shape changes of fuel element claddings under the tensile force effect
[ru]
Представлены методика и результаты испытания 19-элементного фрагмента ТВС ВВЭР-1000 в канале реактора МИР в режиме второй и третьей стадии максимальной проектной аварии. В эксперименте изучается состояние активной зоны реактора, которое возникает при некомпенсируемой утечке среды из первого контура охлаждения при разрыве трубопровода с максимальным диаметром (большая течь). В каждом из рассматриваемых случаев верхняя часть твэлов охлаждается перегретым паром. Основная цель испытания - получение данных о формоизменении оболочек твэлов под воздействием растягивающего усилияOriginal Title
Metodika i rezul'taty ispytaniya v kanale reaktora MIR fragmenta TVS VVEhR-1000 v rezhime maksimal'noj proektnoj avarii