[en] K-type thermocouple is widely used in nuclear power plants (NPP) and they provide reliable service. Generally, the thermocouple assembly is the finished product and usually only nondestructive tests are performed on the assembly, whereas destructive tests are confined to selected bulk cable specimens. This K-type thermocouple has been used representatively in the In-Core Instrument Assembly (ICI) in the nuclear power plants. The ICI consists of five rhodium emitter detectors that provide information on the thermal power for the core and one K-type thermocouple made with two cables (Chromel-Alumel) that provides the temperature of core exit (CET). Generally, the quantity of the ICI is absolutely different according to the number of fuel assemblies in the NPP. In the case of SKN 3 and 4, they were designed to the 61 ICI to provide information on the core cooling to the inadequate core cooling monitoring system (ICCMS). This measured temperature could be also used to check the entry condition of severe accidents. The technology of the TFDR is a generic skill to detect the fault position of the cable. In-core Instruments (ICIs) were used to detect the Core Exit Temperature (CET) in a reactor. This measured temperature was also used to check the entry condition of severe accidents. However, if a serious accident occurs, the upper portion of the core is damaged. This instrument has not been available. This paper illustrates the estimation possibility for the status of molten core through the high-temperature characteristics test of k-type thermocouple. It turns out that it is possible to measure the k-type thermocouple up to 1350 .deg. C degrees before melting during insertion into the melting furnace. Additionally, in order to measure a high temperature of 2000 .deg. C or more, the replacement possibility of k-type thermocouple was evaluated. However the tungsten-rhenium thermocouple is impossible to use in the detection of temperature at the in-core because of the change of elements
Primary Subject
Source
Korean Nuclear Society, Daejeon (Korea, Republic of); [1 CD-ROM]; May 2014; [2 p.]; 2014 spring meeting of the KNS; Jeju (Korea, Republic of); 28-30 May 2014; Available from KNS, Daejeon (KR); 2 refs, 5 figs
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue