[en] Indirectly driven capsule implosions are driven by four shock waves whose strength and relative timing must be controlled to high precision to keep the fuel on a low adiabat. The symmetry during the first 2 ns should be tuned carefully. The mainline tuning targets chosen are the high Z re-emission spheres. For record of instantaneous asymmetry during the first 2 ns, multiple images in the time of the soft X-ray re-emission from a non-imploding Bi ball on SGⅡ facility were taken in 2011. The re-emitted images with hohlraum lengths of 1350 μm and 1500 μm were obtained and the experimental P_2/P_0 and P_4/P_0 time histories were deduced. A simple analytical view-factor model is established, and the simulation result of P_2/P_0 is in agreement with the measured P_2/P_0. (authors)
Primary Subject
Source
7 figs., 8 refs.
Record Type
Journal Article
Journal
High Power Laser and Particle Beams; ISSN 1001-4322; ; v. 25(2); p. 385-388
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue