[en] The transient thermal hydraulic characteristics of 49-2 Swimming Pool Reactor (SPR) were analyzed by RELAP5/MOD3.3 code to verify the capability of natural circulation and minus reactivity feedback for accident mitigation under the condition of station blackout (SBO). Then, the effects on accident consequence and sequence for core channels and primary pumps were briefly discussed. The calculation results show that the reactor can be shutdown by the effect of minus reactivity feedback, and the residual heat can be removed through the stable natural circulation. Therefore, it demonstrates that the 49-2 SPR is safe during the accident of SBO. (authors)
Primary Subject
Source
5 figs., 2 tabs., 4 refs.
Record Type
Journal Article
Journal
Atomic Energy Science and Technology; ISSN 1000-6931; ; v. 46(suppl.); p. 290-294