[en] Room-temperature operating CdZnTe(CZT) material is an innovative radiation detector which could reduce the patient dose to one-tenth level of conventional CT (Computed Tomography) and mammography system. The pixel and pixel pitch in the imaging device determine the conversion efficiency of incident Xor gamma-ray and the cross-talk of signal, that is, image quality of detector system. The weighting potential is the virtual potential determined by the position and geometry of electrode. The weighting potential obtained by computer-based simulation in solving Poisson equation with proper boundaries condition. The pixel was optimized by considering the CIE (charge induced efficiency) and the signal cross-talk in CT detector system. The pixel pitch was 1-mm and the detector thickness was 2-mm in the simulation. The optimized pixel size and inter-pixel distance for maximizing the CIE and minimizing the signal cross-talk is about 750 μm and 125 μm, respectively
Primary Subject
Source
This record replaces 47089662; 6 refs, 6 figs, 1 tab
Record Type
Journal Article
Journal
Journal of Radiological Science and Technology; ISSN 2288-3509; ; v. 39(1); p. 35-42
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue