[en] The optimum scheme for geometric phase measurement in plasma is proposed. The theoretical values of geometric phase for the probe beams of EAST Polarimeter/Interferometer (POINT) system are calculated by path integration in parameter space and the influences of some controllable parameters on geometric phase are evaluated. The feasibility and problems of distinguishing geometric effect in the POINT signal are assessed. (author)
Primary Subject
Source
Hu Liqun (ed.) (Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China)); Morita, Shigeru (ed.) (National Institute for Fusion Science, Toki, Gifu (Japan)); Oh, Yeong-Kook (ed.) (National Fusion Research Institute, Daejeon (Korea, Republic of)); National Institute for Fusion Science, Toki, Gifu (Japan); 277 p; Dec 2015; p. 180-183; A3 foresight program seminar on critical physics issues specific to steady state sustainment of high-performance plasmas 2015 China; Nanning (China); 6-9 Jan 2015; 8 refs.