AbstractAbstract
[en] As a risk assessment technology based on probability, the fire PSA is accepted abroad by nuclear industry in its application in the risk assessment for nuclear power plants. Based on the industry experience, the fire-induced impact on the plant safety during low power and shutdown operation cannot be neglected, therefore fire PSA can be used to assess the corresponding fire risk. However, there is no corresponding domestic guidance/standard as well as accepted analysis methodology up to date. Through investigating the latest evolvement on fire PSA during low power and shutdown operation, and integrating its characteristic with the corresponding engineering experience, an engineering methodology to evaluate the fire risk during low power and shutdown operation for nuclear power plant is established in this paper. In addition, an analysis demonstration as an example is given. (authors)
Primary Subject
Source
China Nuclear Physics Society (China); 206 p; ISBN 978-7-5022-6130-6; ; May 2014; p. 97-102; 2013 academic annual meeting of China Nuclear Society; Harbin (China); 10-14 Sep 2013; 1 fig., 2 tabs., 4 refs.