Bazerghi, H.; Serdula, K.J.
Reactor noise - SMORN II. Proceedings of the 2. specialists meeting on reactor noise, Gatlinburg, Tennessee, USA 19-23 September 19771977
Reactor noise - SMORN II. Proceedings of the 2. specialists meeting on reactor noise, Gatlinburg, Tennessee, USA 19-23 September 19771977
AbstractAbstract
[en] Propagation of inherent inhomogeneities or tracers in flowing liquids is used to measure flow. The peak value obtained from a cross-correlation analysis of downstream and upstream sensor signals is used to determine the tracer transit time and hence the flow. Performance of a 'clamp-on' ultrasonic cross-correlation flowmeter developed by Canadian General Electric under contract from Atomic Energy of Canada Limited (AECL) was evaluated at the Chalk River Nuclear Laboratories of AECL. During this work, the effects of: (1) cross-correlation parameters, (2) filtering of correlator output and (3) use of an add-only polarity coincidence correlator on the standard deviation of transit measurements were investigated both theoretically and experimentally. Comparison of ultra-sonic cross-correlation flowmeter readings against gravimetric flow measurements gave a standard deviation of 2% of reading. (author)
Primary Subject
Secondary Subject
Source
Williams, M.M.R. (ed.) (Queen Mary Coll., London (UK). Dept. of Nuclear Engineering); Progress in Nuclear Energy. New Series; v. 1(2-4); p. 629-648; ISBN 0 08 0221572; ; 1977; p. 629-648; Pergamon Press Ltd; Oxford; Reactor noise - SMORN II; Gatlinburg, USA; 19 - 23 Sep 1977
Record Type
Book
Literature Type
Conference
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Bazerghi, H.; Serdula, K.J.
Atomic Energy of Canada Ltd., Chalk River, Ontario. Chalk River Nuclear Labs.1977
Atomic Energy of Canada Ltd., Chalk River, Ontario. Chalk River Nuclear Labs.1977
AbstractAbstract
[en] An ultrasonic cross-correlation flowmeter, developed to assist in improving performance of heavy water plants, was evaluated. Overall performance of the flowmeter is satisfactory. The flowmeter is ideally suited to industrial applications and has an accuracy and repeatability comparable to many laboratory instruments. An accuracy of 3% is readily obtainable. This new 'clamp-on' portable flowmeter should prove useful in applications which provide flow measurements in systems where pipe penetration is too costly or not practical, verify or replace existing flowmeters, and measure flows in lines not previously instrumented to provide better control or to verify performance of systems
Source
Sep 1977; 24 p; Canadian Nuclear Association 17. annual international conference; Montreal, Quebec, Canada; 5 Jun 1977
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Source
Canadian Nuclear Association, Toronto, Ontario; p. 174-175; nd; p. 174-175; 17. annual international conference of the Canadian Nuclear Association; Montreal, Canada; Jun 1977; Available from Canadian Nuclear Association, Toronto; Published in summary form only.
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue