Abrams, G.; Ashmanskas, W.; Bintinger, D.; Ciocio, S.; Hoff, M.; Kadel, R.W.; Kadyk, J.; Minamihara, Y.; Lim, A.; Long, M.; Pope, W.; Pripstein, M.; Przybylski, G.; Thur, W.; Weber, T.; Yarba, J.; Hearty, C.; Amadon, A.; Bonamy, P.; Bystricky, J.; Ernwein, J.; Glicenstein, J.F.; Hubbard, J.R.; LeDu, P.; Reymond, J.M.; Rondeaux, F.; Villet, G.; Singh, V.; Melese, P.; Hauser, J.; Lindgren, M.; Muller, T.; Rusack, R.; Cushman, P.; Bhatti, A.
Lawrence Berkeley National Lab., CA (United States). Funding organisation: US Department of Energy (United States)1996
Lawrence Berkeley National Lab., CA (United States). Funding organisation: US Department of Energy (United States)1996
AbstractAbstract
No abstract available
Primary Subject
Source
Nuclear Instruments and Methods in Physics Research, Section A; v. 390(1-2); 18 Apr 1996; [vp.]; AC03-76SF00098; Available from Lawrence Berkeley National Lab., CA (United States)
Record Type
Miscellaneous
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Abrams, G.S.; Ashmanskas, W.; Bintinger, D.; Ciocio, S.; Hoff, M.; Kadel, R.W.; Kadyk, J.; Minamihara, Y.; Lim, A.; Long, M.; Pope, W.; Pripstein, M.; Przybylski, G.; Thur, W.; Weber, T.; Yarba, J.; Hearty, C.; Amadon, A.; Bonamy, P.; Bystricky, J.; Ernwein, J.; Glicenstein, J.F.; Hubbard, J.R.; LeDu, P.; Reymond, J.M.; Rondeaux, F.; Villet, G.; Singh, V.; Bhatti, A.; Melese, P.; Hauser, J.; Lindgren, M.; Muller, T.; Cushman, P.; Rusack, R.1997
AbstractAbstract
[en] We have tested a calorimeter test beam module intended to simulate the endcap electromagnetic calorimeter of the solenoidal detector collaboration (SDC) experiment at the SSC. The test module is manufactured from scintillating tiles and is read out via 1 mm diameter wavelength shifting fibers with shower sampling at ∝ 1 radiation length intervals. The results of test beam calibration show that the calorimeter is linear to within 1% and has a resolution of (19.5 ± 0.1)%/√(E) + (0.47% ± 0.05)% for energies up to 200 GeV. Test beam data show that non-uniform, longitudinal radiation damage to the calorimeter (up to ∝50% light loss at shower maximum) can be corrected, and the original linearity of the calorimeter can be recovered with only a small degradation of resolution. A ''pre-shower detector'' improves the charged π rejection by a factor of 2-3 at an electron detection efficiency greater than 97.5 ± 0.3%. (orig.)
Record Type
Journal Article
Journal
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment; ISSN 0168-9002; ; CODEN NIMAER; v. 390(1-2); p. 41-62
Country of publication
CALORIMETERS, EFFICIENCY, ELECTRON DETECTION, ENERGY RESOLUTION, GEV RANGE 100-1000, GEV RANGE 10-100, OPTICAL FIBERS, PARTICLE DISCRIMINATION, PHYSICAL RADIATION EFFECTS, PION DETECTION, PLASTIC SCINTILLATION DETECTORS, PULSES, RELATIVISTIC RANGE, RESPONSE FUNCTIONS, SHOWER COUNTERS, VISIBLE RADIATION
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue