Filters
Results 1 - 10 of 30
Results 1 - 10 of 30.
Search took: 0.024 seconds
Sort by: date | relevance |
AbstractAbstract
[en] Using matrix method it is possible to estimate the tolerances into processing and assembling of the double focusing mass spectrometers. (author)
Original Title
Estimarea influentei erorilor mecanice asupra deformarii imaginii la spectrometrele de masa cu dubla focalizare
Primary Subject
Source
Central Inst. of Physics, Bucharest (Romania); 828 p; 1988; p. 138-139; Advances in Physics; Progrese in Fizica; Constanta (Romania); 6-8 Oct 1988
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Original Title
Aplicarea calcului matricial in optica ionica
Record Type
Journal Article
Journal
Studii si Cercetari de Fizica; v. 27(2); p. 153-173
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The importance of the rate constant of the molecular fragmentation processes in mass spectrometry is estimated. The change of the rate constant with the internal energy of the ions and its importance in the isotopic effects appearing in the course of the fragmentation and in the calculation of mass spectra are discussed. (author)
Original Title
Viteza de reactie a proceselor de fragmentare ce au loc in spectrometrul de masa
Primary Subject
Source
28 refs.
Record Type
Journal Article
Journal
Studii si Cercetari de Fizica; v. 28(7); p. 745-752
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] A new method in water isotopes analysis with mass spectrometer SMAD-2 is proposed. (authors)
Original Title
Marirea vitezei de analiza la spectrometrele SMAD-2
Primary Subject
Source
Central Inst. of Physics, Bucharest (Romania); 828 p; 1988; p. 131-132; Advances in Physics; Progrese in Fizica; Constanta (Romania); 6-8 Oct 1988
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Record Type
Journal Article
Journal
Vacuum; v. 24(6); p.245-247
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The utility of the mass spectrometry, especially of the double focusing mass-spectrometry, in the study of the unimolecular and collision-induced fragmentations is related. The energetic aspects of the upper processes, appearing from the mass spectrometric and spectroscopic measurements on the diatomic and poliatomic ions are described. (author)
Original Title
Energetica tranzitiilor metastabile unimoleculare si induse prin ciocniri studiata cu spectrometre de masa statice
Primary Subject
Source
45 refs.
Record Type
Journal Article
Journal
Studii si Cercetari de Fizica; v. 29(7); p. 711-720
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Using the matrix method the basis parameters of a double focusing mass spectrometer are calculated. The calculus is performed in the second order approximation. The proposed double focusing mass spectrometer is composed of a toroidal electrostatic condenser and an inhomogeneous r-1 magnetic field. (author)
Source
6 refs.
Record Type
Journal Article
Journal
Revue Roumaine de Physique; ISSN 0035-4090; ; v. 25(7); p. 759-765
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Partly deuterated pyridine, examining the kinetic energy spectra of the ions obtained into a double focusing mass spectrometer MAT-311 by MIKE and HV methods, was studied. (authors)
Original Title
Efecte izotopice observate in spectrele de energie cinetica a piridinei deuterate
Primary Subject
Source
Central Inst. of Physics, Bucharest (Romania); 828 p; 1988; p. 142-143; Advances in Physics; Progrese in Fizica; Constanta (Romania); 6-8 Oct 1988
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The ionization and appearance potentials determined by mass spectrometric measurements are affected by the errors, for reasons of the ignoring of the internal energy in excess of the activated complex.(authors)
Original Title
Metoda pentru corectarea caldurilor de formare a ionilor rezultati din ciocniri intr-un spectrometru de masa
Primary Subject
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] A double focusing mass spectrometer with an original geometry (Wien filter-electrostatic analyser) is presented. The image aberrations are corrected with the hexapoles lenses. The relationships for the second order aberrations coefficients in the radial and axial planes are calculated. (authors)
Original Title
Spectrometre de masse a double focalisation a lentiles hexapolaires electrostatiques de correction de l';mage
Source
7 refs.
Record Type
Journal Article
Journal
Revue Roumaine de Physique; ISSN 0035-4090; ; v. 25(7); p. 751-758
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
1 | 2 | 3 | Next |