AbstractAbstract
[en] In this paper the leaden fish form sediment concentration gauge detector, the radiation source automatics and the seal structure are described
Secondary Subject
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; CODEN HDYUE; v. 5(1); p. 30-33
Country of publication
BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CESIUM ISOTOPES, CHEMICAL ANALYSIS, ELECTROMAGNETIC RADIATION, INTERMEDIATE MASS NUCLEI, IONIZING RADIATIONS, ISOTOPES, MEASURING INSTRUMENTS, NONDESTRUCTIVE ANALYSIS, NUCLEI, ODD-EVEN NUCLEI, RADIATION DETECTORS, RADIATIONS, RADIOISOTOPES, YEARS LIVING RADIOISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] An α and β radiation measuring system of simultaneously counting emissions from up to four samples is described. The primary detectors consist of the new low background α and β scintillators of model ST1221 and the low noise PM tube of model GDB-52LD. A single 300 mm x 5 mm plastic scintillator is used as guard detector, 90Sr-90Y β counting efficiency is 60% with typical background of 0.03 cm-2·min-1, αcounting efficiency for 239Pu is 70% with background of 0.03 cm-2·h-1. This instrument is compatible with microcomputer of any type. Measuring and data processing are controlled by computer
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Model BH1217B double channel measuring instrument for monitoring weak α and β radiation with large area semiconductor detector are described. In case of 2π detection efficiency ≥85% (typical value 90%) for 239Pu with typical background of 0.015 cm-2·h-1 and ≥40% (typical value 50%) for 90Sr-90Y with typical background of 0.03 cm-2·h-1. Counting efficiency for α entering β channel: <1%, and for β entering α channel: 0. Data collection, control and processing are all completed by computer
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934; ; CODEN HDYUEC; v. 15(3); p. 136-141, 149
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] In this paper a brief description was given to the structure principle of the detector unit and the model FJ-369 TLD reader. The common trouble and its trouble shooting of the detector unit were listed, and the structure of the detector unit of the advanced model FJ-377 TLD reader was introduced as well
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; v. 2(5); p. 25-29
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Ji Changsong; Dai Zhude; Xie Liangnian; Zhang Shulan; Zhang Shuheng
Proceedings of the '98 national conference on nuclear instrument1999
Proceedings of the '98 national conference on nuclear instrument1999
AbstractAbstract
[en] A high-sensitive equipment monitoring leakage of the reactor fuel elements has been developed. The delayed neutrons emitted from fission product-pioneer nucleus are monitored in the 1st circle water. An array of 3He proportional counter tubes is designed as a neutron detector for delayed neutrons, the detection geometry of which is near to 4π. In order to reduce the influence of interference factors the monitoring of fission product is carried out with 75s delay. The 87Br delayed neutron pioneer nucleus is chosen as a monitoring object. The neutron detection efficiency of the developed equipment is 6.1%, which is 3 times higher than one of all available advanced equipment of the same function both at home and abroad
Secondary Subject
Source
China Electronics Society, Beijing (China); Chinese Nuclear Society, Beijing (China); 172 p; 1999; p. 109-113; '98 National conference on nuclear instruments; Jiangyou, Sichuan (China); 16-23 Sep 1998; Available from China Nuclear Information Centre
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
BARYONS, BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, BROMINE ISOTOPES, COOLING SYSTEMS, DETECTION, ELEMENTARY PARTICLES, ENERGY SYSTEMS, FERMIONS, FISSION NEUTRONS, HADRONS, HYDROGEN COMPOUNDS, INTERMEDIATE MASS NUCLEI, ISOTOPES, MATERIALS, MEASURING INSTRUMENTS, NEUTRON DETECTORS, NEUTRONS, NUCLEI, NUCLEONS, ODD-EVEN NUCLEI, OXYGEN COMPOUNDS, PROPORTIONAL COUNTERS, RADIATION DETECTION, RADIATION DETECTORS, RADIOACTIVE MATERIALS, RADIOISOTOPES, REACTOR COMPONENTS, REACTOR COOLING SYSTEMS, SECONDS LIVING RADIOISOTOPES
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Wu Binglin; Dai Zhude; Fu Fengru; Wen Jiansheng; Jiang Xiaoqiang; Qian Fei; Hu Ransheng
Proceedings of 8. national conference on nuclear electronic and nuclear detection technology: Pt.21996
Proceedings of 8. national conference on nuclear electronic and nuclear detection technology: Pt.21996
AbstractAbstract
[en] A newly developed Model BH1217B double channel measuring instrument with large area semiconductor detector for monitoring low level α β radiation has been described. For 239Pu α source, in case of 2π detection, efficiency ratio ≥90% (typical value 98%), background ≤0.0008/cm2·min(typical value 0.0001/cm2·min). For 90Sr-90Y β source, in case of 2π detection efficiency ratio ≥45% (typical value 60%), background ≤0.008/cm2·min (typical value 0.03/cm2·min). Counting efficiency for α entering β channel: ≤1% (typical value 0.2%), and for β entering α channel: 0. Data collection, data control and data processing are all completed by computer
Source
China Electronics Society, Beijing (China); Chinese Nuclear Society, Beijing, BJ (China); 338 p; 1996; p. 374-377, 403; 8. national conference on nuclear electronics and nuclear detection technology; Zhuhai, GD (China); 2-7 Dec 1996; Available from China Nuclear Information Centre
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Model FT631 Moisture/Density Combined Gauge has been developed, with which both water content and density, the two parameters of measured medium (soil), are obtained in one act of measurement at the same time. A China patent has been taken for this invention
Primary Subject
Secondary Subject
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The Anti-Compton Shield Detector of model FJ422 is introduced. Being used with the ORTEC's HPGe detectors, in the absence of shield, it gives a suppression coefficient of 4.5 to 5.5 in the energy region of 50 to 100 keV for 60Co. The total absorption coefficient of the BGO is compared to that of NaI(Tl), but its volume decreases by 80%
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] A new type of compensated neutron logging probe with glass scintillators has been designed. High sensitivity, long plateau and stability are the features of this probe which differs from the probes with 3He or LiI(Eu) detector. From the results of field application the measured porosity is in good correspondence with the one obtained by rock core sampling method
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The authors present and α and β radiation system of counting emission from up four samples simultaneously. The primary detectors are made of the new low background α and β scintillator of model ST 1221 and the low noise PM tube model GDB-52LD. A single 300 mm x 50 mm plastic scintillator is used as guard detector. 90Sr-90Y counting efficiency is 60% with typical background of 0.03/cm2 · min, counting efficiency for 239Pu is 70% with background of 0.03/cm2· h. This instrument is compatible with microcomputer of any type. Measuring and data processing are controlled by computer
Source
6. national conference on nuclear electronics and nuclear detection technology; Weihai (China); 21-26 Sep 1992; Proceedings of 6th national coference on nuclear electronics and nuclear detection technology (A).
Record Type
Journal Article
Literature Type
Conference
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934; ; CODEN HDYUEC; v. 12(suppl.); p. 342-346, 351
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue