AbstractAbstract
[en] This paper presents the results of the evaluation of the ATWS events with respect to Reactor Coolant System (RCS) overpressure and re-criticality for the European APR1400 (EU-APR1400) according to European Utility Requirement (EUR). This paper evaluates the ATWS impact on the EU-APR1400 by applying EUR. Based on the results of safety analysis for ATWS events, all the acceptance criteria for EUR can be satisfied due to the proper functioning of ATWS mitigation systems. However the four events are investigated only in this paper, and hence the results of this paper can not be concluded that the EU-APR1400 design satisfy all requirements for the EUR. Therefore, a further study for all Design Basis Event Category 2 (DBC2) events with ATWS needs to be performed in order to assess the comprehensive impact of ATWS events for the EU-APR1400 design
Primary Subject
Source
Korean Nuclear Society, Daejeon (Korea, Republic of); [1 CD-ROM]; May 2013; p. 621-622; 2013 spring meeting of the KNS; Kwangju (Korea, Republic of); 29-31 May 2013; Available from KNS, Daejeon (KR); 2 refs, 3 figs, 3 tabs
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue