[en] A pulse generator is described, which is particularly suitable for investigating disturbances in nuclear spectrometry caused by pile-up effects. The pulse generator provides a statistically distributed pulse train controllable in rate and height. (author)
Original Title
Randompulser zur Testung von Kernstrahlungsspektrometern
Record Type
Journal Article
Journal
Isotopenpraxis; v. 13(9); p. 319-320
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] In order to obtain the double digital spread in high resolution nuclear spectrometry, two biased amplifiers were linked in parallel mode to the 10 V-input of a 2k-ADC. The arrangement works like a hybrid (1 bit scale - 11 bits Wilkinson) converter. A careful adjustment of the two bias levels (approximately 0V and approximately 6V) and the post-amplification (approximately 2) delivered a good linearity of the 4k-spectrum. (author)
Source
2 figs.; 1 ref.
Record Type
Journal Article
Journal
Radiochemical and Radioanalytical Letters; v. 32(1-2); p. 7-10
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Original Title
Randompulser
Source
Muenze, R. (ed.); Zentralinstitut fuer Kernforschung, Rossendorf bei Dresden (German Democratic Republic); p. 205-207; Jul 1976; Published in summary form only.
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The installation of a multi-sample beta-gamma coincidence spectrometer in an underground laboratory with a rock covering of 47 m yielded further background reduction by factors of between 10 (at 2 MeV) and about 4 (below 1 MeV). In silicon samples Fe can be measured by neutron activation analysis with a detection limit of 40 pg. (author) 7 refs.; 3 figs
Source
International conference on the separation of ionic solutes (SIS '87); Smolenice (Czechoslovakia); 12-15 Oct 1987
Record Type
Journal Article
Literature Type
Conference
Journal
Journal of Radioanalytical and Nuclear Chemistry; ISSN 0236-5731; ; CODEN JRNCD; v. 129(2); p. 387-391
Country of publication
BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CHARGED PARTICLE DETECTION, COINCIDENCE METHODS, COUNTING TECHNIQUES, DAYS LIVING RADIOISOTOPES, DETECTION, ELEMENTARY PARTICLES, EVEN-ODD NUCLEI, FERMIONS, INTERMEDIATE MASS NUCLEI, IONIZING RADIATIONS, IRON ISOTOPES, ISOTOPES, LEPTONS, MEASURING INSTRUMENTS, NUCLEI, RADIATION DETECTION, RADIATION DETECTORS, RADIATIONS, RADIOISOTOPES, SCINTILLATION COUNTERS, SOLID SCINTILLATION DETECTORS
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Original Title
α-Spektrometrie mit Si(Li)-Driftdetektoren
Primary Subject
Source
Muenze, R. (ed.); Zentralinstitut fuer Kernforschung, Rossendorf bei Dresden (German Democratic Republic); p. 106-109; Dec 1978; p. 106-109; Published in summary form only.
Record Type
Report
Report Number
Country of publication
ACTINIDE NUCLEI, ALPHA DECAY RADIOISOTOPES, AMERICIUM ISOTOPES, CALIFORNIUM ISOTOPES, CHEMICAL ANALYSIS, CURIUM ISOTOPES, EVEN-EVEN NUCLEI, EVEN-ODD NUCLEI, HEAVY NUCLEI, ISOTOPES, LI-DRIFTED DETECTORS, MEASURING INSTRUMENTS, NEPTUNIUM ISOTOPES, NUCLEI, ODD-EVEN NUCLEI, PLUTONIUM ISOTOPES, RADIATION DETECTORS, RADIOISOTOPES, SEMICONDUCTOR DETECTORS, SI SEMICONDUCTOR DETECTORS, SPECTRA, SPECTROSCOPY, YEARS LIVING RADIOISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The microprocessor-based 4096-channel-memory (single stand by crate) allows the parallel coupling of two Ge(Li)-gamma spectrometers via DMA (4 μs dead time) and a programmed input (ca. 150 μs dead time), the accumulation of 32 K counts per channel and the free definition of ROI's. The software organizes the versatile use of low-price periphery (oscilloscope, line printer, key board) and carries out the quantitative evaluation of the spectra. The device has been applied in low- and high-level spectrometry and as a general purpose microprocessor. (author)
Original Title
Kompakter 4096-Kanal-Speicher mit mikroprozessorgestuetzter Spektrenauswertung
Source
3. symposium on nuclear analytical methods; Dresden (German Democratic Republic); 11-15 Apr 1983
Record Type
Journal Article
Literature Type
Conference
Journal
Isotopenpraxis; ISSN 0021-1915; ; v. 21(1); p. 28-31
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Original Title
Pile-Up-Messzeitkorrektur
Source
Muenze, R. (ed.); Zentralinstitut fuer Kernforschung, Rossendorf bei Dresden (German Democratic Republic); p. 207-208; Jul 1976; Published in summary form only.
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Record Type
Journal Article
Journal
Nuclear Instruments and Methods; v. 118(1); p. 217-220
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Niese, S.; Goerner, W.; Kleeberg, H.
International conference on low radioactivity measurement and applications. The High Tatras, 6-10 October 19751975
International conference on low radioactivity measurement and applications. The High Tatras, 6-10 October 19751975
AbstractAbstract
No abstract available
Source
Komenskeho Univerzita, Bratislava (Czechoslovakia). Prirodovedecka Fakulta; Ustav pro Vyzkum, Vyrobu a Vyuziti Radioisotopu, Prague (Czechoslovakia); p. 64; Oct 1975; International conference on low radioactivity measurement and applications; Smokovec, High Tatras, Czechoslovakia; 6 Oct 1975; Published in summary form only.
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] In comparison to normal gamma spectrometry the application of X-γ coincidence spectrometry improves the detection limit for most of EC-decaying radionuclides. The described arrangement is suitable for low-level measurements of EC-decaying nuclides with atomic numbers higher than 30. (author)
Original Title
Messanordnung zur X-γ-Koinzidenzspektrometrie geringer Aktivitaeten von Elektroneneinfangstrahlen
Record Type
Journal Article
Journal
Isotopenpraxis; v. 12(3); p. 120-122
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
1 | 2 | Next |