AbstractAbstract
[en] We examined the pre-operative MRI of 97 cases of lumbar disc herniation retrospectively. Ninety-two cases (95%) had vertebral signal changes, end plate erosions and/or vertebral posterior corner changes. Thirty-seven (47%) cases of 78 histological examinations had a cartilaginous end plate. Patients whose MRI showed high signal intensity on both T1 and T2 weighted images near the end plates, had a high incidence of having the end plates in the prolapsed disc herniations. We must recognize the lumbar disc herniation as the injured state of the disc and endplates. (author)
Primary Subject
Record Type
Journal Article
Journal
Seikei-Saigai Geka; ISSN 0387-4095; ; v. 45(3); p. 237-242
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] In conventional three-dimensional (3D)-CT image processing, the images are influenced by subjective threshold settings. The purpose of this study was to evaluate an objective threshold setting technique based on the discriminant analysis method. The concentration of contrast medium in a joint of a simulated upper cervical spine phantom was changed, and its threshold was measured from scanned data by using the discriminant analysis method, and mean CT attenuation was measured. On the other hand, an accurate image of the corresponding joint in the phantom was made, and its minimum threshold was measured. Regression analysis between the adjusted minimum threshold and mean CT attenuation of the region of contrast medium was performed. The obtained linear regression formula was applied to the threshold settings in five cases for atlanto-axial 3D-CT facet arthrogram (3D-CTF), and the accuracy of the images was examined. There was a strong correlation between the adjusted threshold and mean CT attenuation, and the obtained linear regression formula was y=0.625x-141 (r2=0.991, p<0.01). This equation could be used clinically for correction of the threshold settings. We propose the following method for threshold setting of 3D-CTF: the threshold of the region of contrast medium is measured using the discriminant analysis method, then the adjusted minimum threshold for the threshold settings of 3D-CTF is calculated from mean CT attenuation. The method described herein is an objective, general-purpose methodology that is applicable to various types of 3D-CT. (author)
Primary Subject
Record Type
Journal Article
Journal
Nippon Hoshasen Gijutsu Gakkai Zasshi; ISSN 0369-4305; ; v. 63(5); p. 603-608
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume