Courtat, P.; Charlet, D.; Lebon, S.; Martin, J.M.; Sellem, R.; Wanlin, E.; Douet, R.; Harroch, H.; Bimbot, L.; Jouan, D.; Kharmandarian, L.; Le Bornec, Y.; Mac Cormick, M.; Willis, N.
Paris-11 Univ., 91 - Orsay (France). Inst. de Physique Nucleaire1999
Paris-11 Univ., 91 - Orsay (France). Inst. de Physique Nucleaire1999
AbstractAbstract
[en] A full scale prototype of one module of the first tracking station has already been constructed. It will be equipped with the new read-out electronics proposed for the final chambers. Before integration of the whole chain, tests have been carried out on the individual components in discrete circuit prototypes. The different parts of the chain are described, together with the tests performed. The final version with integrated circuits in then described. (author)
Primary Subject
Source
1999; 61 p; 8 refs.
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Blumenfeld, Y.; Barbier, A.; Beaumel, D.; Charlet, D.; Clavelin, J.F.; Douet, R.; Engrand, M.; Lebon, S.; Lelong, P.; Lesage, A.; Leven, V.; Lhenry, I.; Marechal, F.; Petizon, L.; Pouthas, J.; Richard, A.; Rougier, D.; Soulet, C.; Suomijaervi, T.; Volkov, P.; Voltolini, G.
Paris-11 Univ., 91 - Orsay (France). Inst. de Physique Nucleaire1996
Paris-11 Univ., 91 - Orsay (France). Inst. de Physique Nucleaire1996
AbstractAbstract
[en] This report states the specificity of light particles elastic scattering, and the need of detecting recoil protons to improve angular resolution. Then the development of a specific MUST strip detector is detailed: 60 strips detectors with Si O sub 2 dielectric, that yield 500 ps time resolution, and Si (Li) detectors following next. A versatile data acquisition system has been developed too, with CAMAC interface to suit to any experimental plant. (D.L.)
Original Title
MUST, un ensemble de detecteurs a pistes pour l'etude des reactions induites par faisceaux radioactifs
Secondary Subject
Source
1996; 32 p; 27 refs.
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Blumenfeld, Y.; Marechal, F.; Barbier, A.; Beaumel, D.; Charlet, D.; Clavelin, J.F.; Courtat, P.; Douet, R.; Engrand, M.; Khan, E.; Lavergne, L.; Lebon, S.; Lelong, P.; Lesage, A.; Ven, V.L.; Lhenry, I.; Martin, J.M.; Pita, S.; Petizon, L.; Pollacco, E.; Pouthas, J.; Richard, A.; Rougier, D.; Santonocito, D.; Scarpaci, J.A.; Soulet, C.; Stutzmann, J.S.; Suomijaervi, T.; Volkov, P.; Voltolini, G.; Auger, F.; Ottini, S.; Alamanos, N.; Gillibert, A.; Lapoux, V.; Lagoyannis, A.; Musumarra, A.; Sida, J.L.; Sauvestre, J.E.; Bonnereau, B.; Delbourgo-Salvador, P.; Ethvignot, T.; Szmigiel, M.1999
AbstractAbstract
[en] A new and innovative array, MUST, based on silicon strip technology and dedicated to the study of reactions induced by radioactive beams on light particles is described. The detector consists of 8 silicon strip - Si(Li) telescopes used to identify recoiling light charged particles through time of flight, energy loss and energy measurements and to determine precisely their scattering angle through X, Y position measurements. Each 60x60 mm2 double sided silicon strip detector with 60 vertical and 60 horizontal strips yields an X-Y position resolution of 1 mm, an energy resolution of 50 keV, a time resolution of around 1 ns and a 500 keV energy threshold for protons. The backing Si(Li) detectors stop protons up to 25 MeV with a resolution of approximately 50 keV. CsI crystals read out by photo-diodes which stop protons up to 70 MeV are added to the telescopes for applications where higher energy particles need to be detected. The dedicated electronics in VXIbus standard allow us to house the 968 logic and analog channels of the array in one crate placed adjacent to the reaction chamber and fully remote controlled, including pulse visualization on oscilloscopes. A stand alone data acquisition system devoted to the MUST array has been developed. Isotope identification of light charged particles over the full energy range has been achieved, and the capability of the system to measure angular distributions of states populated in inverse kinematics reactions has been demonstrated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)
Primary Subject
Source
Country of input: Belarus
Record Type
Journal Article
Journal
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment; ISSN 0168-9002; ; CODEN NIMAER; v. 421(3); p. 471-491
Country of publication
BARYONS, CATIONS, CHARGED PARTICLES, DISTRIBUTION, ELECTRON SPECTROSCOPY, ELEMENTARY PARTICLES, ENERGY RANGE, FERMIONS, HADRONS, HYDROGEN IONS, HYDROGEN IONS 1 PLUS, IONS, LI-DRIFTED DETECTORS, MEASURING INSTRUMENTS, MEV RANGE, NUCLEONS, RADIATION DETECTORS, SCATTERING, SEMICONDUCTOR DETECTORS, SI SEMICONDUCTOR DETECTORS, SPECTROSCOPY
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Blumenfeld, Y.; Auger, F.; Sauvestre, J.E.; Marechal, F.; Ottini, S.; Alamanos, N.; Barbier, A.; Beaumel, D.; Bonnereau, B.; Charlet, D.; Clavelin, J.F.; Courtat, P.; Delbourgo-Salvador, P.; Douet, R.; Engrand, M.; Ethvignot, T.; Gillibert, A.; Khan, E.; Lapoux, V.; Lagoyannis, A.; Lavergne, L.; Lebon, S.; Lelong, P.; Lesage, A.; Le Ven, V.; Lhenry, I.; Martin, J.M.; Musumarra, A.; Pita, S.; Petizon, L.; Pollacco, E.; Pouthas, J.; Richard, A.; Rougier, D.; Santonocito, D.; Scarpaci, J.A.; Sida, J.L.; Soulet, C.; Stutzmann, J.S.; Suomijaervi, T.; Szmigiel, M.; Volkov, P.; Voltolini, G.1999
AbstractAbstract
[en] A new and innovative array, MUST, based on silicon strip technology and dedicated to the study of reactions induced by radioactive beams on light particles is described. The detector consists of 8 silicon strip - Si(Li) telescopes used to identify recoiling light charged particles through time of flight, energy loss and energy measurements and to determine precisely their scattering angle through X, Y position measurements. Each 60x60 mm2 double sided silicon strip detector with 60 vertical and 60 horizontal strips yields an X-Y position resolution of 1 mm, an energy resolution of 50 keV, a time resolution of around 1 ns and a 500 keV energy threshold for protons. The backing Si(Li) detectors stop protons up to 25 MeV with a resolution of approximately 50 keV. CsI crystals read out by photo-diodes which stop protons up to 70 MeV are added to the telescopes for applications where higher energy particles need to be detected. The dedicated electronics in VXIbus standard allow us to house the 968 logic and analog channels of the array in one crate placed adjacent to the reaction chamber and fully remote controlled, including pulse visualization on oscilloscopes. A stand alone data acquisition system devoted to the MUST array has been developed. Isotope identification of light charged particles over the full energy range has been achieved, and the capability of the system to measure angular distributions of states populated in inverse kinematics reactions has been demonstrated
Primary Subject
Source
S0168900298011784; Copyright (c) 1999 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment; ISSN 0168-9002; ; CODEN NIMAER; v. 421(3); p. 471-491
Country of publication
ALKALI METAL COMPOUNDS, BEAMS, CESIUM COMPOUNDS, ENERGY RANGE, HALIDES, HALOGEN COMPOUNDS, INORGANIC PHOSPHORS, IODIDES, IODINE COMPOUNDS, ION BEAMS, LI-DRIFTED DETECTORS, MEASURING INSTRUMENTS, MEV RANGE, PHOSPHORS, RADIATION DETECTORS, SCINTILLATION COUNTERS, SEMICONDUCTOR DETECTORS, SI SEMICONDUCTOR DETECTORS
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue