AbstractAbstract
[en] The software system of γ-camera adopts visualizing and interactive human-computer interface, collecting and displaying the data of patients in real time. Through a series of dealing with the collected data then it put out the medical record in Chinese. This system also can retrieve and backup the data of patients. Besides, it can assist the doctor to diagnose the illness by applying the clinical quantitative analysis function of the system. (authors)
Primary Subject
Secondary Subject
Source
Nuclear Electronics and Nuclear Detection Technology Branch Society, Beijing (China); 384 p; 2006; p. 750-753; 13. national conference on nuclear electronics and nuclear detection technology; Xi'an (China); 21-25 Oct 2006; Available from China Nuclear Information Centre; 3 figs., 3 refs.
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] This paper introduces the principle of the position calibration in positron emission tomography detector module. A optimization algorithm of position calibration is elaborated, which used the output of the photomultipliers to calculate the position of the events, and based on the events count in different positions to educe the rough border of the 64 little detectors. Finally, position calibration of detector module in PET is achieved with iterative computation. (authors)
Primary Subject
Source
Nuclear Electronics and Nuclear Detection Technology Branch Society, Beijing (China); 384 p; 2006; p. 408-410; 13. national conference on nuclear electronics and nuclear detection technology; Xi'an (China); 21-25 Oct 2006; Available from China Nuclear Information Centre; 4 figs., 6 refs.
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] To make all PMT's gains identical through auto-adjustment is important for ensuring the PET imaging quality. The response output depends on the light collecting efficiency in the position where the event happens and the energy of light quantum. Light collecting efficiency of PMT in the position is in proportion to solid angle of the PMT at the position. The adjusting value was calculated by the algorithm described in the paper. The result showed that the algorithm was effective in practice. (authors)
Primary Subject
Secondary Subject
Source
3 figs., 5 refs.
Record Type
Journal Article
Journal
Nuclear Techniques; ISSN 0253-3219; ; v. 28(12); p. 943-946
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue