Bernard, A.; Garconnet, J.P.; Jolas, A.; Mascureau, J. de.
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1981
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1981
AbstractAbstract
[en] A fast valve injects gas transiently near the insulator in order to optimize pressures separately for breakdown and beam generation. On a different machine without gas injection the interaction of the ion beam with targets of variable thicknesses can be used to diagnose the beam
Primary Subject
Source
Jul 1981; 8 p; 4. International topical conference on high-power electron and ion-beam research and technology; Palaiseau, France; 29 Jun - 3 Jul 1981
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Bernard, A.; Garconnet, J.P.; Jolas, A.; Le Breton, J.P.; Mascureau, J. de.
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1982
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1982
AbstractAbstract
[en] Ion beams created in a plasma focus electrical discharge are evidenced and measured from interaction with CD2 and DLi targets. Aluminum targets are also used with observation of the radiation temperature and material expansion velocity. Comparison between experimental measurements and numerical computations allows to determine energy deposition in the aluminum foil as well as beams values. With the 200 kJ Actime facility 2 to 3 MJ/g deposition is obtained in aluminum on approximately one square centimeter. A fast valve gas injection has been developed on another facility and preliminary results are given
[fr]
On etudie les faiceaux d'ions emis par une decharge electrique focalisante. L'utilisation de cibles de CD2 et de DLi permet de mettre en evidence ces faisceaux et de mesurer leurs caracteristiques. On utilise egalement des cibles d'aluminium et on developpe des moyens de diagnostic pour mesurer la temperature de rayonnement et la vitesse d'expansion de la matiere. La confrontation des resultats experimentaux avec le code de calcul numerique permet une determination des depots d'energie realises. Avec l'installation Actime 200 kJ on determine des depots de 2 a 3 MJ/g dans l'aluminium sur une surface de 1 cm. On donne les premiers resultats obtenus avec une installation munie d'une injection de gaz par vanne rapideOriginal Title
Etude et utilisation des faisceaux d'ions engendres dans l'experience Focus
Primary Subject
Source
Jun 1982; 45 p
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Bourgade, J.L.; Cavailler, C.; Mascureau, J. de; Miquel, J.L.
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1986
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1986
AbstractAbstract
[en] Improvement in laser-plasma analysis makes it necessary to perform accurate calibration in the soft X-ray range. For this purpose we have modified a plasma Focus device (27 kJ, 40 kV, 400 kA) in order to enhance its soft X-ray emission: a hollow anode is used to prevent hard X-ray bremsstrahlung emission and a lot of filling gases are chosen for their characteristic lines in the keV and sub-keV range (Ne, Ar, O, N, CH4). These emissions have been absolutely measured with a X-ray bolometer and can be used directly or indirectly (in the fluorescent mode: Mg Kα at 1.254 keV) for X-ray calibration of various diagnostics. Some detector calibrations in pulsed regime (10 ns) are presented (Films, solid state PIN diodes, CCD arrays)
Primary Subject
Source
Mar 1986; 16 p; Meeting on high temperature plasma diagnostics; Hilton Head Island, SC (USA); 9-13 Mar 1986
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Bernard, A.; Garconnet, J.P.; Jolas, A.; Le Breton, J.P.; Mascureau, J. de.
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1978
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1978
AbstractAbstract
[en] In plasma focus experiments the essential phenomenon is the turbulent interaction of electrical current with plasma which leads to the generation of intense beams of electrons and ions. These are responsible for the high emission of X-rays and neutrons by interaction with the anode and the filling deuterium, respectively. The ion beam can also be directly used on a massive deuterated polyethylene target. At 25 mm from the anode of a 340 kJ - 40 kV facility one measures an average deuteron current of 1.2 MA during 30 ns. The mean energy of the deuterons is 300 keV. Scaling laws cover a large range of experiments between 20 kA and 2 MA
Primary Subject
Source
1978; 10 p; 2. International conference on energy storage, compression and switching; Venice, Italy; 5 - 9 Dec 1978; Copies available from Service de Documentation, CEN Saclay, BP no.2, 91190 Gif-sur-Yvette (France)
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Bernard, Alain; Jolas, Alain; Garconnet, J.-P.; Mascureau, J. de; Nazet, Christian; Coudeville, Alain; Bekiarian, Andre.
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1977
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1977
AbstractAbstract
[en] The present report is the edition of the lectures given in a conference on the Focus experiment held at the Centre d'etudes de Limeil, on Oct. 1975. After a survey of the early laboratories one will find the main results obtained in Limeil concerning interferometry, laser scattering, electric and magnetic-measurements, X-ray and neutron emission and also the possible use of explosive current generators instead of capacitor banks at high energy levels. The principal lines of future research are given in the conclusion
[fr]
Ce rapport contient les textes des exposes presentes le 10 octobre 1975 au Centre d'Etudes de Limeil, lors d'une conference consacree au plasma Focus. Apres un historique et un etat actuel des travaux dans le monde on presente les principaux resultats experimentaux obtenus par interferometrie, diffusion Thomson, sondes electriques et magnetiques, etude des rayonnements X et neutronique ainsi que les possibilites des generateurs a explosif pour remplacer les condensateurs a niveau d'energie eleve. On donne en conclusion les axes principaux de recherches pour l'avenirOriginal Title
Le plasma Focus
Primary Subject
Source
Jan 1977; 104 p
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The historical account of induction linacs is briefly presented. The principle of operation is then explained and the main parameters for induction cell dimensioning are reviewed. The developments of induction technology at DAM are illustrated through the realizations of the LELIA linac devoted to Free Electron Laser (FEL) application and the PIVAIR prototype for the AIRIX Flash X-ray Radiography project. Within this frame we describe the induction cell technology development. (author)
Original Title
Le developpement de la technologie des accelerateurs a induction
Primary Subject
Source
17 refs.
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Bernard, Alain; Coudeville, Alain; Garconnet, J.-P.; Jolas, A.; Mascureau, J. de; Nazet, Christian.
CEA Centre d'Etudes de Bruyeres-le-Chatel, 92 - Montrouge (France)1976
CEA Centre d'Etudes de Bruyeres-le-Chatel, 92 - Montrouge (France)1976
AbstractAbstract
[en] In a Mather-Focus experiment, it was shown that 80% of the neutron emitted were generated through bombardment. The apparatus was operated with various targets at a distance of 13mm from the anode. In the low pressure regime, a deuteron beam of high energy was produced. Its emission duration was measured using a CD2 target
[fr]
Dans une experience Focus de type Mather on montre que plus de 80% des neutrons sont crees par bombardement. On a fait fonctionner une installation avec des cibles variees placees a seulement 13mm de l'anode. Dans le regime basse pression on met en evidence un faisceau de deuterons de grande energie dont la duree d'emission a ete mesuree en utilisant une cible en CD2Original Title
Bombardement de cibles par les faisceaux d'ions engendres dans l'experience Focus
Primary Subject
Source
9 Nov 1976; 12 p
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Sauneuf, A.; Cavailler, C.; Henry, Ph.; Launspach, J.; Mascureau, J. de; Rostaing, M.
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1984
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1984
AbstractAbstract
[en] An axisymmetric microscope with 10 X magnification has been constructed; its resolution has been measured using severals grids, backlighted by an X-ray source and found to be near 25 μm. So it could be used to make images of laser driven plasmas in the soft X-ray region. In order to see rapidly those images we have associated it with a new detector. It is a small image converter tube with a soft X-ray photocathode and a P20 phosphor deposited on an optic fiber plate. The electronic image appearing on the screen is read by a CCD working in the spectral range. An electronic image readout chain, which is identical to those we use with streak cameras, then processes automatically and immediatly the images given by the microscope
Source
Nov 1984; 10 p; Meeting of the plasma physics division of the american physical society; Boston, MA (USA); 20 Oct - 2 Nov 1984
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Bernard, A.; Garconnet, J.P.; Jolas, A.; Le Breton, J.P.; Mascureau, J. de; Romary, P.
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1979
CEA Centre d'Etudes de Limeil, 94 - Villeneuve-Saint-Georges (France)1979
AbstractAbstract
[en] The purpose of the present talk is to give the most important results concerning plasma focus research at the Centre d'Etudes de Limeil. At first we will describe the structure of the current sheath during the axial propagation. Then we will speak about the singularity phase and the associate turbulent resistivity which comes before the beam phase. And we will see that plasma focus can be considered as the most powerful ion beam generator
Primary Subject
Source
1979; 21 p; International conference on plasma science; Montreal, Canada; 4 - 6 Jun 1979
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Dense and hot plasmas, created by interaction of a laser beam with a metallic target, radiate an important part of the absorbed energy in soft X-ray range. For the first time in this type of experiment a bolometer have been studied and used to measure this X-ray emission. This X-ray calorimeter presents many advantages: no effect due to thermal losses, fast response (20 ns), insensibility to the laser light and ions emission, high sensitivity (3.7+-0.2)x10-3 V.J-1.m2 and low threshold 1 J.m-2, possibility of direct electrical calibration. The results obtained with this bolometer are in good agreement with those given by a broad band spectrometer used in the same experimental condition
[fr]
Les plasmas denses et chauds, crees lors de l'interaction d'un faisceau laser de puissance avec une cible solide reemettent une part importante de l'energie qu'ils absorbent sous forme de rayonnement X mou. Pour la premiere fois dans ce type d'experience, un bolometre a ete mis au point et utilise pour mesurer cette energie rayonnee. Ce calorimetre X presente pour ces mesures de bilan d'energie de nombreux avantages: absence d'influence des pertes thermiques, temps de reponse rapide de 20 ns, insensibilite aux photons laser et aux ions produits, sensibilite elevee de (3,7+-0,2).10-3 V.J-1.m2 et seuil de detection faible de 1 J.m-2, possibilite d'etalonnage electrique direct. Les resultats obtenus avec ce bolometre sont en bon accord avec ceux mesures dans les memes conditions experimentales avec un spectrometre a large bandeOriginal Title
Premiere utilisation d'un bolometre pour la calorimetrie du rayonnement X emis par un plasma cree par laser
Primary Subject
Record Type
Journal Article
Journal
Comptes Rendus des Seances de l'Academie des Sciences. Serie 2; ISSN 0249-6305; ; CODEN CRSUD; v. 301(13); p. 895-900
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
1 | 2 | 3 | Next |