Filters
Results 1 - 10 of 38
Results 1 - 10 of 38.
Search took: 0.019 seconds
Sort by: date | relevance |
Fernandez, C.; Fouz, M.C.; Marin, J.; Oller, J.C.; Willmott, C.; Amigo, L.J.
Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain)2002
Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain)2002
AbstractAbstract
[en] Part of the readout system for the CMS muon drift chambers has been tested in test beams at CERN/GIF. Read Out Board (ROB) and HPTD have been validated with signals from a real muon beam, with an structure and flux similar to LHC operating conditions and using one of the chambers produced in CIEMAT already located in the test beam area under normal gas and voltage conditions. (Author) 5 refs
Original Title
Validacion en el Test Beam del CERN/GIF de la Electronica de Lectura de las Camaras de Muones del Experimento CMS
Primary Subject
Source
2002; 20 p
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The authors describe the control system developed for the automated growth of HgI2 crystals, mainly used for X and γ radiation detectors. The system includes instrumentation for the precise measurement of the growth furnace temperatures and for their control, both needed to fulfill the strict requirements of the vapor phase crystal growth. A video camera and a VME grabber module allow the detection of the crystal nucleation and pattern recognition. This image analysis is used as input for the control actions. A VME based computer (MVM147SA-1 from Motorola) running a real time OS9 operating system performs: data collection, instrumentation programming, image acquisition, data analysis and control of the whole system making use of a highly structured software. The image analysis is done by means of a perceptron neural net classifier using a parameter invariant representation of the objects detected in the segmented images
Primary Subject
Secondary Subject
Source
Conference on real-time computer applications in nuclear, particle and plasma physics (RT); East Lansing, MI (United States); 22-26 May 1995; CONF-950534--
Record Type
Journal Article
Literature Type
Conference
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Arce, P.; Barcala, J.M.; Calvo, E.; Ferrando, A.; Josa, M.I.; Molinero, A.; Navarrete, J.; Oller, J.C.
Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain)2015
Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain)2015
AbstractAbstract
[en] In this document Magnet Cycles and Stability Periods of the CMS Experiment are studied with the recorded Alignment Link System data along the 2008 to 2013 years of operation. The motions of the mechanical structures due to the magnetic field forces are studied including an in-depth analysis of the relative distance between the endcap structures and the central Tracker body during the Stability Periods to verify the mechanical stability of the detector during the physics data taking.
Original Title
Ciclos de Campo Magnético y Periodos de Estabilidad de las Estructuras del Experimento CMS de 2008 a 2013 Observados por el Sistema de Alineamiento
Primary Subject
Source
2015; 80 p; Also available in the CIEMAT library; 43 refs.
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Alberdi, J.; Arce, P.; Barcala, J.M.; Calvo, E.; Ferrando, A.; Josa, M.I.; Molinero, A.; Navarrete, J.; Oller, J.C.; Yuste, C.
Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain)2007
Centro de Investigaciones Energeticas Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain)2007
AbstractAbstract
[en] We present the instructions for the use of the electrolytic tilt meters installed in the link alignments system of the CMS experimental and give the Data Base to be used as a Handbook during CMS operation. (Author) 16 refs
Primary Subject
Source
2007; 39 p
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Arce, P.; Fernandez, M.G.; Ferrando, A.; Josa, M.I.; Molinero, A.; Oller, J.C.; Calvo, E.; Figueroa, C.F.; Rodrigo, T.; Vila, I.; Virto, A.L., E-mail: ferrando@ae.ciemat.es2004
AbstractAbstract
[en] A novel, accurate and inexpensive device for measuring short distances is presented. Data taken with a very simple prototype are presented and its performance is extracted
Primary Subject
Source
S0168900203024173; Copyright (c) 2003 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment; ISSN 0168-9002; ; CODEN NIMAER; v. 517(1-3); p. 378-380
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
External URLExternal URL
Berdugo, J.; Fernandez, M.G.; Ferrando, A.; Josa, M.I.; Molinero, A.; Oller, J.C.; Arce, P.; Calvo, E.; Figueroa, C.F.; Garcia, N.; Rodrigo, T.; Vila, I., E-mail: ferrando@1e.ciemat.es1999
AbstractAbstract
[en] Semitransparent amorphous silicon sensors have been proposed as the 2D positioning sensors for the link system of the CMS alignment. We have developed a general method to characterise these sensors, from the signal reconstruction to the beam distortion. First test results with a few sensors are here reported
Primary Subject
Secondary Subject
Source
S0168900298014430; Copyright (c) 1999 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: Syrian Arab Republic
Record Type
Journal Article
Journal
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment; ISSN 0168-9002; ; CODEN NIMAER; v. 425(3); p. 469-479
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Fernandez, M.G.; Ferrando, A.; Josa, M.I.; Molinero, A.; Oller, J.C.; Arce, P.; Calvo, E.; Figueroa, C.F.; Garcia, N.; Rodrigo, T.; Vila, I.; Virto, A.L., E-mail: ferrando@ae.ciemat.es2000
AbstractAbstract
[en] Semitransparent amorphous silicon sensors have been proposed as the 2D positioning sensors for the link system of the CMS alignment. An in-depth study of the actual performance of these sensors is here reported
Primary Subject
Source
S0168900299009638; Copyright (c) 2000 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment; ISSN 0168-9002; ; CODEN NIMAER; v. 440(2); p. 372-387
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Arce, P.; Calvo, E.; Figueroa, C.F.; Garcia, N.; Rodrigo, T.; Vila, I.; Virto, A.L.; Barcala, J.M.; Fernandez, M.G.; Ferrando, A.; Josa, M.I.; Molinero, A.; Oller, J.C., E-mail: ferrando@ae.ciemat.es2002
AbstractAbstract
[en] A first global test of the CMS Alignment System was performed at the I4 hall of the CERN ISR tunnel. Positions of the network, reproducing a set of points in the CMS detector monitored by the Link System, were reconstructed and compared to survey measurements. Spatial and angular reconstruction precisions reached in the present experimental set-up are already close to the CMS requirements
Primary Subject
Secondary Subject
Source
S0168900202014122; Copyright (c) 2002 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment; ISSN 0168-9002; ; CODEN NIMAER; v. 492(3); p. 365-375
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Fernandez, M.G.; Ferrando, A.; Josa, M.I.; Molinero, A.; Oller, J.C.; Arce, P.; Calvo, E.; Figueroa, C.F.; Garcia, C.F.; Rodigrido, T.; Vila, I.; Virto, A.L.
Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain)1998
Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas (CIEMAT), Madrid (Spain)1998
AbstractAbstract
[en] A new, accurate and un expensive device for measuring short distances, intended for monitoring in LHC experiments is presented. Data taken with a very simple prototype are shown and performance is extracted. (Author) 4 refs
Source
1998; 16 p
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Fernandez, M.G.; Ferrando, A.; Josa, M.I.; Molinero, A.; Oller, J.C.; Arce, P.; Calvo, E.; Figueroa, C.F.; Garcia, N.; Matorras, F.; Rodrigo, T.; Vila, I.; Virto, A.L., E-mail: ferrando@uae1.ciemat.es2000
AbstractAbstract
[en] Semitransparent amorphous silicon sensors are the key elements for laser light 2D position reconstruction in the CMS alignment system. Some of them have to work in very extreme radiation environment. We have irradiated with gammas, up to 10 MRad, two different sensors and measured their change in performance
Primary Subject
Source
S0168900299008888; Copyright (c) 2000 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: Pakistan
Record Type
Journal Article
Journal
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment; ISSN 0168-9002; ; CODEN NIMAER; v. 439(1); p. 111-116
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
1 | 2 | 3 | Next |