Hill, D.; Fletcher, O.; Moretti, A.; Onesto, F.
Argonne National Lab., Ill. (USA)1976
Argonne National Lab., Ill. (USA)1976
AbstractAbstract
[en] Standard operating procedures are presented for the vacuum, cryogenic, and electronic systems of a polarized proton target. The systems are comprised of (1) a target cryostat; (2) a 4He pumping system; (3) a 3He pumping system; (4) a microwave system; (5) a magnet and power supply; (6) a computerized polarization monitor; and (7) miscellaneous auxiliary equipment
Primary Subject
Source
Jan 1976; 61 p; Available from NTIS; Available from NTIS. $4.50.
Record Type
Report
Report Number
Country of publication
BARYONS, CATIONS, CHARGED PARTICLES, CONTROL EQUIPMENT, ELECTRICAL EQUIPMENT, ELECTRONIC EQUIPMENT, ELEMENTARY PARTICLES, EVEN-EVEN NUCLEI, EVEN-ODD NUCLEI, FERMIONS, HADRONS, HELIUM ISOTOPES, HYDROGEN IONS, HYDROGEN IONS 1 PLUS, IONS, ISOTOPES, LIGHT NUCLEI, MAGNETS, NUCLEI, NUCLEONS, STABLE ISOTOPES, TARGETS, THERMOSTATS
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Hill, D.; Moretti, A.; Onesto, F.; Rynes, P.
Argonne National Lab., Ill. (USA)1976
Argonne National Lab., Ill. (USA)1976
AbstractAbstract
[en] A revision is given of a manual containing standard operating procedures for the vacuum, cryogenic, and electronic systems of a polarized proton target. The discussion includes the target cryostat, the 3He and 4He pumping systems, remote monitors and controls, the microwave system, the magnet and power supply, the computerized polarization monitor, the 4He liquifier and gas recovery system, and miscellaneous auxiliary equipment
Original Title
Operation manual
Primary Subject
Source
Apr 1976; 113 p; Available from NTIS. $5.50.
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Hill, D.; Moretti, A.; Onesto, F.; Rynes, P.
Argonne National Lab., Ill. (USA)1978
Argonne National Lab., Ill. (USA)1978
AbstractAbstract
[en] The manual presented contains certain standard operating procedures for the vacuum, cryogenic, and electronic systems of PPT-III. In total, these systems comprise the following major divisions: (1) the target cryostat; (2) the 4He pumping system; (3) the 3He pumping system; (4) the remote monitors and controls; (5) the microwave system; (6) the magnet and power supply; (7) the computerized polarization monitor; (8) the 4He liquefier and gas recovery system; and (9) miscellaneous auxiliary equipment
Primary Subject
Source
Jan 1978; 114 p; Available from NTIS., PC A06/MF A01
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue