Filters
Results 1 - 1 of 1
Results 1 - 1 of 1.
Search took: 0.019 seconds
AbstractAbstract
[en] A full-sized model for the horizontally oriented metal cask containing 21 spent fuel assemblies has been considered to evaluate the internal natural convection behavior within a dry shield canister (DSC) filled with helium as a working fluid. A variety of two-dimensional CFD numerical investigations using a turbulent model have been performed to evaluate the heat transfer characteristics and the velocity distribution of natural convection inside the canister. The present numerical solutions for a range of Rayleigh number values (3 Χ 106∼3 Χ 107) and a working fluid of air are further validated by comparing with the experimental data from previous work, and they agreed well with the experimental results. The predicted temperature field has indicated that the peak temperature is located in the second basket from the top along the vertical center line by effects of the natural convection. As the Rayleigh number increases, the convective heat transfer is dominant and the heat transfer due to the local circulation becomes stronger. The heat transfer characteristics show that the Nusselt numbers corresponding to 1.5 Χ 106 < Ra < 1.0 Χ 107 are proportional to 0.5 power of the Rayleigh number, while the Nusselt numbers for 1.0 Χ 107 < Ra < 8 Χ 107 are proportional to 0.27 power of the Rayleigh number. These results agreed well with the trends of the experimental data for Ra>1.0 Χ 107
Primary Subject
Source
15 refs, 10 figs, 1 tab
Record Type
Journal Article
Literature Type
Numerical Data
Journal
Nuclear Engineering and Technology; ISSN 1738-5733; ; v. 45(7); p. 969-978
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue