Reich, E.; Boegl, K.W.
Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene; Bundesministerium fuer Umwelt-, Naturschutz und Reaktorsicherheit, Bonn (Germany, F.R.)1989
Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene; Bundesministerium fuer Umwelt-, Naturschutz und Reaktorsicherheit, Bonn (Germany, F.R.)1989
AbstractAbstract
[en] The quality control was carried through at seven different generators sold on the market of the Federal Republic of Germany, which were all loaded with fission molybdenum. The Mo-99 content of the aluminium oxide column was measured. Determination of the elution efficiency, measurement of the pH-value of the eluate as well as a test to detect soluble aluminium in the eluate were also performed. Application, quality of accessories and their practicability was tested at all generators. The methods of analysis chosen were, among others, gamma spectrometry and thinlayer chromatography; the measuring methods were a site-sensitive proportional counter (measurement of the distribution of radioactivity on the chromatograms) and the atomic absorption spectrometry. The quality control of the Tc-99 m eluates had satisfying results. The eluates showed - with one exception - high and sufficient radionuclidic purity and very good radiochemical purity. A considerable overload of the column with Mo-99 at the period of reference was not found. The elution yields with values of 85% and 122% were in good agreement with the requirements. All eluates had pH-values between 5.0 and 6.5, and an aluminium content below 1 μg/ml. The generators had good performance and proved generally to be a reliable source for the generation of Tc-99 m pertechnetate. The application was safe and, with some exceptions, fulfilled the requirements. (orig./HP)
[de]
Die Qualitaetskontrolle wurde an sieben verschiedenen in der Bundesrepublik Deutschland kommerziell vertriebenen Generatoren, die alle mit Spaltmolybdaen beladen waren, durchgefuehrt. Bestimmung der Elutionsausbeute, Messung des pH-Wertes im Eluat sowie die Pruefung auf loesliches Aluminium im Eluat wurden ebenfalls vorgenommen; ausserdem an allen Generatoren deren Handhabung, Qualitaet des Zubehoers sowie dessen Praktikabilitaet getestet. Als Analysemethoden wurden u.a. die Gammaspektrometrie und die Duennschichtchromatographie, als Messverfahren ein ortsempfindlicher Proportionalzaehler (Messung der Radioaktivitaetsverteilung auf den Chromatogrammen) sowie die Atombasorptionsspektrometrie gewaehlt. Die Qualitaetskontrolle der Tc-99 m Eluate lieferte zufriedenstellende Ergebnisse. Die Eluate zeigten mit einer Ausnahme hohe und ausreichende radionukleare Reinheit und sehr gute radiochemische Reinheit. Eine nennenswerte Ueberladung der Saeule mit Mo-99 zum Referenzzeitpunkt konnte nicht festgestellt werden. Die Elutionsausbeuten lagen mit Werten zwischen 85% und 122% im Rahmen der gestellten Forderungen. Alle Eluate hatten pH-Werte zwischen 5.0 und 6.5 und einen Aluminiumgehalt unter 1 μg/ml. Die Generatoren erbrachten eine gute Leistung und erwiesen sich weitgehend als zuverlaessige Quelle fuer die Erzeugung von Tc-99 m Pertechnetat. Die Handhabung war sicher und erfuellte mit wenigen Ausnahmen die gestellten Ansprueche. (orig./HP)Original Title
Chemische, radiochemische und radionukleare Reinheit der Eluate von verschiedenen Mo-99/Tc-99m Generatoren
Primary Subject
Secondary Subject
Source
Feb 1989; 149 p; ISBN 3-89254-066-7; ; Available from Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene
Record Type
Report
Report Number
Country of publication
BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CONTROL, COUNTING TECHNIQUES, DAYS LIVING RADIOISOTOPES, DEVELOPED COUNTRIES, DRUGS, EUROPE, EVEN-ODD NUCLEI, HOURS LIVING RADIOISOTOPES, INTERMEDIATE MASS NUCLEI, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, LABELLED COMPOUNDS, MATERIALS, MEDICINE, MOLYBDENUM ISOTOPES, NUCLEI, ODD-EVEN NUCLEI, RADIOACTIVE MATERIALS, RADIOISOTOPE SCANNING, RADIOISOTOPES, SEPARATION PROCESSES, TECHNETIUM ISOTOPES, YEARS LIVING RADIOISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Other than determining the radiochemical purity of several radiopharmaceuticals, a comparison of the different measuring methods of distributing activity on radiochromatograms or electropherograms is intended by this study. For this, the activity distribution in the developed radiochromatograms was assessed by four different measuring methods (TLC-linear analyzer, DC-scanner with NaI(Tl) detector, DC-scanner with gas flow counter and gamma-sample-counter. As shown by the analysis, only the TLC-linear analyzer and the gamma-sample-counter (measurement of chromatograms or electropherograms cut into strips) are generally suitable methods for determining the radiochemical purity of radiochemicals, the DC-scanner with gas flow counter is usable in most cases, while DC-scanner with NaI(Tl) detector is yielding unsatisfactory results. (orig./PW)
[de]
Hauptziel der Arbeit war neben der Bestimmung der radiochemischen Reinheit einiger Radiopharmaka ein Vergleich verschiedener Messverfahren fuer die Aktivitaetsverteilung auf den Radiochromatogrammen bzw. den Elektropherogrammen. Hierzu wurde die Aktivitaetsverteilung auf den entwickelten Chromatogrammen mit vier verschiedenen Messmethoden bestimmt (TLC-Linear Analyzer, DC-Scanner mit NaI(Tl)-Detektor, DC-Scanner mit Gasstromzaehler und Gamma-Probenwechsler). Wie die Ergebnisse zeigen, sind nur der TLC-Linear Analyzer und der Gamma-Probenwechsler (Messung der in Streifen geschnittenen Chromatogramme bzw. Elektropherogramme) generell benutzbare Messverfahren zur Bestimmung der radiochemischen Reinheit von Radiopharmaka, waehrend der DC-Scanner mit Gasstromzaehler in den meisten Faellen geeignet ist, der DC-Scanner mit NaI(Tl)-Detektor jedoch unzureichende Ergebnisse liefert. (orig./PW)Original Title
Vergleichende Untersuchung von verschiedenen Messverfahren an Radiochromatogrammen zur Beurteilung der radiochemischen Reinheit von zehn Radiopharmaka
Source
Feb 1984; 105 p; CONTRACT ST.SCH. 938; Available from Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene
Record Type
Report
Report Number
Country of publication
BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, BETA-PLUS DECAY RADIOISOTOPES, CHEMICAL ANALYSIS, CHEMISTRY, CHROMIUM ISOTOPES, COBALT ISOTOPES, COUNTING TECHNIQUES, DAYS LIVING RADIOISOTOPES, DIAGNOSTIC TECHNIQUES, DRUGS, ELECTRON CAPTURE RADIOISOTOPES, EVALUATION, EVEN-ODD NUCLEI, HEAVY NUCLEI, HOURS LIVING RADIOISOTOPES, INFORMATION, INTERMEDIATE MASS NUCLEI, IRON ISOTOPES, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, LABELLED COMPOUNDS, MATERIALS, NUCLEI, ODD-EVEN NUCLEI, ODD-ODD NUCLEI, RADIOACTIVE MATERIALS, RADIOISOTOPE SCANNING, RADIOISOTOPES, SEPARATION PROCESSES, TECHNETIUM ISOTOPES, THALLIUM ISOTOPES, YEARS LIVING RADIOISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] 14 different types of pharmaceutical tablets, 18 different pharmaceutical powders, and 32 other solid substances (foodstuffs, environmental materials, etc.) were tested. The results from pharmaceutical powders have shown after optimizing the test conditions that, in some pharmaceuticals, radiation doses of less than 1 Gy were still detectable. Other pharmaceuticals either demonstrated only a slight increase in intensity or none at all. For pharmaceuticals in tablet form, the sample must be processed prior to measurement (deteriorating the detection limit). For examining the various solid substances, materials were selected which are non-soluble or only poorly soluble in luminol solution. All samples were exposed to a radiation dose of 100 Gy. When extrapolating on the basis of a linear dose-effect relation-ship into a lower dose range, it becomes clear that it will be very difficult, if it is possible at all, to find any poorly soluble materials in the liminol solution which could indicate an exposure in the area of 10 Gy or below. (orig./HP)
[de]
14 verschiedene Arzneimittel in Tablettenform, 18 verschiedene Arzneimittelpulver, sowie 32 andere Feststoffe (Lebensmittel, Umweltmaterialien, etc.) wurden ueberprueft. Die Ergebnisse an Arzneimittelpulvern zeigen, dass nach Optimierung der Versuchsbedingungen an einigen Arzneimitteln Strahlendosen noch unterhalb 1 Gy nachgewiesen werden koennen. Andere Arzneimittel zeigen dagegen im Vergleich zur unbestrahlten Kontrollprobe eine ueberhaupt nicht, oder nur gering erhoehte Intensitaet. Bei Arzneimitteln in Tablettenform muss vor der Messung eine Aufbereitung der Proben durchgefuehrt werden (Verschlechterung der Nachweisgrenze). Bei den Untersuchungen an unterschiedlichsten Feststoffen wurden speziell Materialien ausgewaehlt, die in der Luminolloesung nicht, bzw. wenig loeslich sind. Saemtliche Proben wurden mit einer Strahlendosis von 100 Gy bestrahlt. Extrapoliert man unter Zugrundelegung einer linearen Dosiswirkungsbeziehung in den Bereich niedriger Dosen, so ist klar zu erkennen, dass es, wenn ueberhaupt, sehr schwierig sein wird, in der Luminolloesung wenig loesliche Materialien zu finden, die eine Bestrahlung im Bereich von 10 Gy und darunter anzeigen koennen. (orig./HP)Original Title
Die Messung der Chemilumineszenz von Feststoffen als moegliches Indikator-System zur schnellen Dosisermittlung nach Strahlenunfaellen?
Source
Jun 1987; 123 p; ISBN 3-89254-029-2; ; CONTRACT ST.SCH.985; Available from Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] 14 different types of pharmaceutical tablets, 18 different pharmaceutical powders, and 32 other solid substances (foodstuffs, environmental materials, etc.) were tested as to their suitability for a rapid dose assessment by chemiluminescence measurement. The results from the examined pharmaceutical powders have shown after optimizing the test conditions that, in some pharmaceuticals, radiation doses of less than 1 Gy were still detectable. For pharmaceuticals in tablet form, the sample must be processed prior to chemilumescence measurement. This mechanical process strongly increases the chemiluminescence intensity also of non-irradiated samples and is thus responsible for deteriorating the detection limit. For examining the various solid substances, materials were selected which are non-soluble or only poorly soluble in luminol solution. All samples were exposed to a radiation dose of 100 Gy. When extrapolating on the basis of a linear dose-effect relationship into a lower dose range, it will be very difficult, to find any poorly soluble materials in the luminol solution which could indicate an exposure in the area of 10 Gy or below. This is mainly due to the fact that with insoluble samples the only reaction taking place is the one between the luminol solution and the radiolysis products on the surface. (orig./HP)
[de]
14 verschiedene Arzneimittel in Tablettenform, 18 verschiedene Arzneimittelpulver, sowie 32 andere Feststoffe (Lebensmittel, Umweltmaterialien, etc.) wurden ueberprueft, ob durch Chemilumineszenzmessungen an ihnen eine schnelle Dosisermittlung moeglich ist. Die Ergebnisse an Arzneimittelpulvern zeigen, dass nach Optimierung der Versuchsbedingungen an einigen Arzneimitteln Strahlendosen noch unterhalb 1 Gy nachgewiesen werden koennen. Bei Arzneimitteln in Tablettenform muss vor der Chemilumineszenzmessung eine Aufbereitung der Proben durchgefuehrt werden. Diese mechanische Verarbeitung fuehrt zu einem sehr starken Anstieg der Chemilumineszenz-Intensitaeten auch von unbestrahlten Proben und damit auch zu einer Verschlechterung der Nachweisgrenze. Bei den Untersuchungen an unterschiedlichsten Feststoffen wurden speziell Materialien ausgewaehlt, die in der Luminolloesung nicht, bzw. wenig loeslich sind. Saemtliche Proben wurden mit einer Strahlendosis von 100 Gy bestrahlt. Extrapoliert man unter Zugrundelegung einer linearen Dosiswirkungsbeziehung in den Bereich niedriger Dosen, so ist zu erkennen, dass es sehr schwierig sein wird, in der Luminolloesung wenig loesliche Materialien zu finden, die eine Bestrahlung im Bereich von 10 Gy und darunter anzeigen koennen. Dies ist vor allem darauf zurueckzufuehren, dass bei unloeslichen Proben nur eine Reaktion der an der Oberflaeche befindlichen Radiolyseprodukte mit der Luminolloesung stattfindet. (orig./HP)Original Title
Die Messung der Chemilumineszenz von Feststoffen als moegliches Indikator-System zur schnellen Dosisermittlung nach Strahlenunfaellen
Secondary Subject
Source
Schriftenreihe Reaktorsicherheit und Strahlenschutz; 1987; 124 p; CONTRACT ST.SCH. 985; Available from GRM Werbeberatung - Werbemittlung - PR, Eggenstein-Leopoldshafen, (Germany, F.R.)
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Some marketable I-131/I-125/I-123 o-iodohippuric acids were analysed from March to June 1984 with regard to their radiochemical purity and stability. As method of analysis thin layer chromatography was chosen and as method of measurement a TLC linear analyzer was used. At the same time the in vitro stability of the listed radiopharmaceuticals was taken into consideration. It turned out that the I-131 products are subject to a great decomposition. A comparison drawn from several HPLC-measuring methods showed that the selected method of thin-layer chromatography lead to a far better separation of the radiochemical impurities. (orig./PW)
[de]
Einige auf dem Markt befindliche J-131/J-125/J-123 Orthojodhippurane wurden von Maerz bis Juni 1984 auf ihre radiochemische Reinheit und in vitro Stabilitaet untersucht. Als Analysenmethode wurde die Duennschichtchromatographie, als Messverfahren wurde ein TLC Linear Analyzer ausgewaehlt. Zugleich wurde die in vitro Stabilitaet der aufgefuehrten Radiopharmaka betrachtet. Es zeigte sich, dass die J-131 Produkte einer grossen Zersetzung unterliegen. Ein Vergleich mit verschiedenen HPLC-Methoden ergab, dass die ausgewaehlte duennschichtchromatographische Methode eine bessere Auftrennung der radiochemischen Verunreinigungen zulaesst. (orig./PW)Original Title
Die radiochemische Reinheit und Stabilitaet von J131/J125/J123 Orthojodhippursaeuren
Source
Aug 1984; 88 p; ISBN 3-924404-19-8; ; CONTRACT ST.SCH. 938; Available from Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene
Record Type
Report
Report Number
Country of publication
BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CHEMICAL ANALYSIS, CHEMISTRY, CONTRAST MEDIA, COUNTING TECHNIQUES, DAYS LIVING RADIOISOTOPES, DIAGNOSTIC TECHNIQUES, DRUGS, ELECTRON CAPTURE RADIOISOTOPES, EVALUATION, HOURS LIVING RADIOISOTOPES, INTERMEDIATE MASS NUCLEI, IODINE ISOTOPES, ISOTOPES, LABELLED COMPOUNDS, MATERIALS, NUCLEI, ODD-EVEN NUCLEI, RADIOACTIVE MATERIALS, RADIOISOTOPE SCANNING, RADIOISOTOPES, SEPARATION PROCESSES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] This manual for use in the nuclear medical laboratory is dealing with the quality control of in vivo radiopharmaceuticals while considering the theoretical background of various influencial parameters. Practical and theoretical guidelines are given for quality control tests, as well as possible technical error sources that may result in chromatography related artefacts. The emphasis of this manual lies in a compilation of methods used to analyse the radiochemical impurity of in vivo radiopharmaceuticals. The content of the manual is divided into 6 parts. Part 1 refers to general quality control aspects. Part 2 provides an overview of quality control principles and methods. Part 3 contains the most commonly in vivo radiopharmaceuticals used in tabular form, along with their area of use and current producers/distributors in the Federal Republic of Germany (status December 1985). A compilation of essential analytical methods for investigating radiochemical impurities of in vivo radiopharmaceuticals in nuclear medical routine use is contained in part 4 of the manual. Part 5 describes the most important technical error possibilities in radiochemical quality control. The list of references (part 6) contains review studies of quality control as well as original reports of all of the analytical methods listed. (orig./MG)
[de]
Dieses Handbuch fuer das nuklearmedizinische Labor behandelt Fragen der Qualitaetskontrolle von in-vivo Radiopharmaka, wobei auch auf die theoretischen Hintergruende der verschiedenen Einflussparameter eingegangen wird. Es werden Hinweise zur Theorie und zur praktischen Durchfuehrung von Qualitaetspruefungen beim Anwender gegeben und moegliche arbeitstechnische Fehlerquellen, die zur Artefaktbildung bei der Chromatographie fuehren koennen, aufgezeigt. Schwerpunkt dieses Handbuches ist die Zusammenstellung von Verfahren zur Analytik radiochemischer Verunreinigungen von in-vivo Radiopharmaka. Der Inhalt dieses Handbuches gliedert sich in 6 Teile. Teil 1 behandelt allgemeine Aspekte der Qualitaetskontrolle. Teil 2 gibt einen Ueberblick ueber Grundlagen und Durchfuehrung der Qualitaetskontrolle. Teil 3 beinhaltet in tabellarischer Form die meist verwendeten in-vivo Radiopharmaka, ihr Anwendungsgebiet und die zur Zeit in der Bundesrepublik Deutschland taetigen Hersteller/Vertreiber (Stand Dezember 1985). Eine Zusammenstellung von wesentlichen Analysenverfahren zur Analytik radiochemischer Verunreinigung fuer die in der nuklearmedizinischen Routine angewandten in-vivo Radiopharmaka gibt Teil 4. Teil 5 beschreibt die wichtigsten arbeitstechnischen Fehlermoeglichkeiten bei der radiochemischen Qualitaetskontrolle. Das Literaturverzeichnis (Teil 6) beruecksichtigt sowohl Uebersichtsarbeiten zur Qualitaetskontrolle als auch Originalarbeiten zu saemtlichen aufgefuehrten Analysenverfahren. (orig./MG)Original Title
Qualitaetskontrolle von in-vivo Radiopharmaka
Secondary Subject
Source
Jun 1986; 227 p; ISBN 3-924403-99-6; ; CONTRACT ST.SCH. 938; Available from Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Knoepnadel, I.; Schuettler, C.; Reich, E.; Boegl, W.
Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene1983
Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene1983
AbstractAbstract
[en] The report explains the course of experiments and the method applied (including bibliographic data). The specimens selected for examination are fully described (charge numbers and date of calibration). The number of analyses per charge is given, together with information on parallel analyses made on samples of a given charge (number and dates) during the period of stability of the radiopharmaceuticals. (orig./PW)
[de]
Neben der Versuchsbeschreibung des ausgewaehlten Verfahrens (mit Literaturstelle) sind hier Angaben zu den untersuchten Arzneimittelchargen (Chargennummer und Kalibrierungsdatum) zu finden, die Anzahl der Analysen pro Charge und zu wievielen Zeitpunkten waehrend der Haltbarkeit des Arzneimittels Parallelbestimmungen bei einer Charge durchgefuehrt wurden. (orig./PW)Original Title
Bestimmung der radiochemischen Reinheit von zehn Radiopharmaka
Source
Aug 1983; 181 p; CONTRACT ST.SCH. 757 H; Available from Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene
Record Type
Report
Literature Type
Numerical Data
Report Number
Country of publication
BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, BETA-PLUS DECAY RADIOISOTOPES, CHEMICAL ANALYSIS, CHEMISTRY, CHROMIUM ISOTOPES, COBALT ISOTOPES, COUNTING TECHNIQUES, DAYS LIVING RADIOISOTOPES, DIAGNOSTIC TECHNIQUES, DRUGS, ELECTRON CAPTURE RADIOISOTOPES, EVEN-ODD NUCLEI, HEAVY NUCLEI, HOURS LIVING RADIOISOTOPES, INFORMATION, INTERMEDIATE MASS NUCLEI, IODINE ISOTOPES, IRON ISOTOPES, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, LABELLED COMPOUNDS, MATERIALS, NUCLEI, NUMERICAL DATA, ODD-EVEN NUCLEI, ODD-ODD NUCLEI, RADIOACTIVE MATERIALS, RADIOISOTOPE SCANNING, RADIOISOTOPES, SEPARATION PROCESSES, TECHNETIUM ISOTOPES, THALLIUM ISOTOPES, YEARS LIVING RADIOISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Hammermaier, A.; Reich, E.; Endrulat, H.J.; Boegl, W.
Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene1985
Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene1985
AbstractAbstract
[en] Seven different Mo-99/Tc-99m generators, based on fission Mo-99, from seven different manufacturers were studied from September 1984 to January 1985 with regard to their performance and to the quality of the eluates. Results for elution efficiencies, radionuclidic purity, Mo-99 breakthrough, radiochemical purity, pH, and aluminium content of the eluates are presented. (orig./PW)
[de]
Sieben verschiedene Mo-99/Tc-99m Generatoren, beladen mit Spaltmolybdaen, wurden von September 1984 bis Januar 1985 bezueglich ihrer Leistung und Qualitaet der Eluate untersucht. Ergebnisse der Elutionsausbeute, Radionuklidreinheit, Mo-99 Durchbruch, radiochemische Reinheit, pH und Aluminiumgehalt der Eluate werden vorgelegt. (orig./PW)Primary Subject
Secondary Subject
Source
Mar 1985; 84 p; ISBN 3-924403-47-3; ; CONTRACT ST.SCH. 938; Available from Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene
Record Type
Report
Literature Type
Numerical Data
Report Number
Country of publication
BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CONTROL, DATA, DAYS LIVING RADIOISOTOPES, DISSOLUTION, EVEN-ODD NUCLEI, HOURS LIVING RADIOISOTOPES, INFORMATION, INTERMEDIATE MASS NUCLEI, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, MEDICINE, MOLYBDENUM ISOTOPES, NUCLEI, NUMERICAL DATA, ODD-EVEN NUCLEI, OXYGEN COMPOUNDS, RADIOISOTOPES, SEPARATION PROCESSES, SPECTRA, SPECTROSCOPY, TECHNETIUM COMPOUNDS, TECHNETIUM ISOTOPES, TRANSITION ELEMENT COMPOUNDS, YEARS LIVING RADIOISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Hammermaier, A.; Reichert, T.; Reich, E.; Boegl, K.W.
Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene1987
Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene1987
AbstractAbstract
[en] The purpose of the present study is to examine radiochemical impurities in nine MDP and DTPA kits distributed by different producers and labeled with Tc-99m. Five I-123/I-131 MIBG or amphetamine products from three producers were also impurity tested, together with the in vitro stability of these radiopharmaceuticals. Paper and thin-layer chromatography was used for analysis, next to a position sensitive gas flow counter for measuring the radioactivity distribution on the chromatograms. The study of Tc-99m MDP and TPA basically showed two different radioactive impurities: free pertechnetate and hydrolysed technetium. Free pertechnetate was observed in only a few of the samples: the values were less than 1% of total radioactivity in all cases. Radioiodine labeled MIBG had a free iodide impurity of 1-2.5% of total activity, showing traces of also a second impurity. The radiochemical purity study of I-123 amphetamines resulted in free iodide values of about 1.5%. (orig./RB)
[de]
In der vorliegenden Arbeit wurden neun jeweils von verschiedenen Herstellern vertriebene MDP und DTPA Kits, nachdem sie mit Tc-99m markiert wurden, auf ihre radiochemische Reinheit untersucht. Fuenf I-123/I-131 MIGB bzw. Amphetamin-Produkte von drei Herstellern wurden ebenfalls auf ihre radiochemische Reinheit getestet. Ausserdem wurde die in vitro Stabilitaet der Radiopharmaka untersucht. Als Analysenmethoden wurden Papier- und Duennschichtchromatographie und als Messverfahren (Messung der Radioaktivitaetsverteilung auf den Chromatogrammen) ein ortsempfindlicher Proportionalzaehler gewaehlt. Grundsaetzlich wurden zwei verschiedene radioaktive Verunreinigungen bei der Untersuchung von Tc-99m MDP und DTPA gefunden: Freies Pertechnetat und hydrolysiertes Technetium. Freies Pertechnetat fand sich nur in wenigen Proben, in allen Faellen lagen die Werte unter 1% der Gesamtradioaktivitaet. Mit Radiojod markiertes MIBG enthielt als radiochemische Verunreinigung freies Jodid zwischen 1-2.5% der Gesamtaktivitaet und eine zweite Verunreinigung in Spuren. Die radiochemische Reinheitsuntersuchung von I-123 Amphetaminen ergab fuer freies Jodid Werte im Bereich um 1.5%. (orig./RB)Original Title
Chromatographische Kontrolle der radiochemischen Reinheit von Tc-99m Methylendiphosphonat (MDP), Tc-99m Diethylentriaminpentaessigsaeure (DTPA), I-131/I-123 Metajodbenzylguanidin (MIBG) und I-123 Jodamphetamin (IAMP)
Source
Nov 1987; 114 p; ISBN 3-89254-047-0; ; CONTRACT BMU ST.SCH. 938; Available from Bundesgesundheitsamt, Neuherberg (Germany, F.R.). Inst. fuer Strahlenhygiene
Record Type
Report
Report Number
Country of publication
AMPHETAMINES, AUTONOMIC NERVOUS SYSTEM AGENT, CONTAMINATION, DTPA, GUANIDINES, IMPURITIES, INTERNAL CONVERSION RADIOISOTO, IODINE 123, IODINE 131, ISOMERIC NUCLEI, PHOSPHONATES, QUALITY ASSURANCE, QUALITY CONTROL, RADIOCHROMATOGRAPHY, RADIOPHARMACEUTICALS, STABILITY, STORAGE, TECHNETIUM 99, THIN-LAYER CHROMATOGRAPHY
AMINES, AMINO ACIDS, ANALEPTICS, BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CARBONIC ACID DERIVATIVES, CARBOXYLIC ACIDS, CENTRAL NERVOUS SYSTEM AGENTS, CHELATING AGENTS, CHROMATOGRAPHY, CONTROL, DAYS LIVING RADIOISOTOPES, DRUGS, ELECTRON CAPTURE RADIOISOTOPES, HOURS LIVING RADIOISOTOPES, INTERMEDIATE MASS NUCLEI, IODINE ISOTOPES, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, LABELLED COMPOUNDS, MATERIALS, NUCLEI, ODD-EVEN NUCLEI, ORGANIC ACIDS, ORGANIC COMPOUNDS, ORGANIC NITROGEN COMPOUNDS, ORGANIC PHOSPHORUS COMPOUNDS, RADIOACTIVE MATERIALS, RADIOISOTOPES, RADIOPROTECTIVE SUBSTANCES, RESPONSE MODIFYING FACTORS, SEPARATION PROCESSES, SYMPATHOMIMETICS, TECHNETIUM ISOTOPES, YEARS LIVING RADIOISOTOPES
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Quality was controlled of seven different 99Mo/99mTc generators sold in the Federal Republic of Germany, which were all loaded with fission molybdenum. Aim of the work was to test the 99mTc eluates for their radionuclidic and radiochemical purity. Furthermore, the 99Mo content of the aluminium oxide column was measured. Determination of the elution efficiency, measurement of the pH-value of the eluate as well as a test to detect soluble aluminium in the eluate were also performed. In addition to the chemical and physical examinations, application, quality of accessories and their practicability were tested at all generators. The methods of analysis chosen were, among others, gamma spectrometry and thin-layer chromatography; the measuring methods were a site-sensitive proportional counter (measurement of the distribution of radioactivity of the chromatograms) and atomic absorption spectrometry (Al content of the eluates). The quality control of the 99mTc eluates had satisfying results. The eluates showed - with one exception - high and sufficient radionuclidic purity and very good radiochemical purity. A considerable overload of the columns with 99Mo at the time of reference was not found. The elution yields with values between 85 and 122% were in good agreement with the requirements. All eluates had pH-values between 5.0 and 6.5, and an aluminium content below 1 μg/ml. The generators had good performance and proved generally to be a reliable source of 99mTc-pertechnetate. The application was safe and, with some exceptions, fulfilled the requirements. (orig.)
Primary Subject
Secondary Subject
Record Type
Journal Article
Journal
Country of publication
ATOMIC IONS, BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CHARGED PARTICLES, CONTROL, DAYS LIVING RADIOISOTOPES, DISPERSIONS, DRUGS, EQUIPMENT, EVALUATION, EVEN-ODD NUCLEI, EXTRACTION APPARATUSES, HOMOGENEOUS MIXTURES, HOURS LIVING RADIOISOTOPES, INTERMEDIATE MASS NUCLEI, IONS, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, LABELLED COMPOUNDS, MATERIALS, MEDICINE, MIXTURES, MOLYBDENUM ISOTOPES, NUCLEI, ODD-EVEN NUCLEI, OXYGEN COMPOUNDS, RADIOACTIVE MATERIALS, RADIOISOTOPES, SEPARATION EQUIPMENT, SOLUTIONS, SPECTROSCOPY, SYNTHESIS, TECHNETIUM COMPOUNDS, TECHNETIUM ISOTOPES, TRANSITION ELEMENT COMPOUNDS, YEARS LIVING RADIOISOTOPES