Seeger, W.
Kernforschungszentrum Karlsruhe G.m.b.H. (Germany, F.R.). Inst. fuer Reaktorbauelemente; Karlsruhe Univ. (T.H.) (Germany, F.R.). Fakultaet fuer Maschinenbau1985
Kernforschungszentrum Karlsruhe G.m.b.H. (Germany, F.R.). Inst. fuer Reaktorbauelemente; Karlsruhe Univ. (T.H.) (Germany, F.R.). Fakultaet fuer Maschinenbau1985
AbstractAbstract
[en] The phase separation and pressure drop of a gas-liquid mixture flowing throuth a T-junction of equal pipe diameters (d = 50 mm) was investigated. The inlet pipe was orientated horizontally, the branch directions were horizontal and vertically upward or downward. The experiments were performed with air-water flow (0.4 < p < 1 MPa) and steam-water flow at pressures up to 10 MPa. The inlet mass flux and quality were varied in a wide range and included test parameters in the slug, annular and dispersed flow regimes. For constant inlet parameters the mass flux ratio G3/G1 between the inlet (1) and branch (3) was varied between 0 and 1. At the same time, detailed differential pressure drop measurements along the inlet, run and branch were carried out to determine the pressure drop in the T-junction. A comparison was made of different models describing the pressure difference Δpsub(1-3) between the inlet and branch and the pressure difference Δpsub(1-2) between the inlet and run on the one hand, and the experimental results, on the other hand. For the branch with upward orientation the T-junction acts as a good separator since nearly all of the gas flows through the branch. For the horizontal branch, the gas preferentially flows into the branch at high values of G3/G1. The quality ratio x3/x1 has a maximum at about G3/G1. For the downward branch the separation is strongly affected by the phase distribution in the inlet pipe; in general, gas flows predominantly into the branch at very high values of G3/G1, whereas this applies for liquid at low values. Empirical correlations have been derived to describe the phase separation for all three branch orientations. The best results of modelling Δpsub(1-2) and Δpsub(1-3) are shown by the model of Reimann-Seeger for all variations of the parameters. (orig.)
[de]
In Gas-Fluessigkeitsstroemung wurden Untersuchungen zur Phasenumverteilung und zum Druckverlust in einem T-Stueck mit gleichen Rohrdurchmessern (d=50 mm) durchgefuehrt. Bei horizontalem Zustrom wurden die waagerechte sowie die vertikal nach oben und nach unten orientierte Abzweiganordnung untersucht. Es wurden Luft-Wasser Experimente bei 0,4 bis 1 MPa durchgefuehrt sowie Dampf-Wasser Experimente bei Druecken bis zu 10 MPa. Der Massenstrom und Gasgehalt des Zustroms wurden derart variiert, dass ein breites Spektrum von Stroemungsformen ueberdeckt wurde (Schwall-, Ring-, disperse Stroemung). Fuer konstante Zustrom-Parameter wurde das Massenstromdichteverhaeltnis G3/G1 zwischen Zustrom (1) und Abzweig (3) zwischen 0 und 1 variiert. Gleichzeitig wurden ausfuehrliche Differenzdruckmessungen entlang des Stroemungsweges im Zustrom, Abstrom und Abzweig vorgenommen, um die Druckverluste im T-Stueck zu bestimmen. Es wurden verschiedene Modelle fuer den Druckverlust ΔPsub(1-3) zwischen Zustrom und Abzweig und die Druckaenderung Δpsub(1-2) zwischen Zustrom und Abstrom mit den experimentellen Ergebnissen verglichen. Fuer den vertikal nach oben gerichteten Abzweig verhaelt sich das T-Stueck nahezu wie ein guter Separator, da das Gas fast vollstaendig durch den Abzweig stroemt. Fuer den waagerecht angeordneten Abzweig stroemt das Gas bevorzugt fuer hohe Werte von G3/G1 in den Abzweig. Das Verhaeltnis der Dampfgehalte x3/x1 hat ein Maximum bei G3/G1 approx.= 0,3 und nimmt fuer kleinere Werte von G3/G1 stark ab. Fuer den nach unten gerichteten Abzweig wurde eine starke Abhaengigkeit von der Phasenverteilung im Zustrom (Stroemungsform) beobachtet; i.a. stroemt das Gas fuer sehr hohe Werte G3/G1 bevorzugt in den Abzweig und die Fluessigkeit bei niedrigen Werten. Fuer alle drei Abzweigorientierungen wurden empirische Beziehungen fuer die Phasenseparation angegeben. (orig.)Original Title
Untersuchungen zum Druckabfall und zur Massenstromumverteilung von Zweiphasenstroemungen in rechtwinkligen Rohrverzweigungen
Primary Subject
Source
Mar 1985; 135 p; Diss.
Record Type
Report
Literature Type
Thesis/Dissertation
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Reismann, J.; John, H.; Seeger, W.
Kernforschungszentrum Karlsruhe G.m.b.H. (Germany, F.R.). Inst. fuer Reaktorbauelemente; Kernforschungszentrum Karlsruhe G.m.b.H. (Germany, F.R.). Projekt Nukleare Sicherheit1981
Kernforschungszentrum Karlsruhe G.m.b.H. (Germany, F.R.). Inst. fuer Reaktorbauelemente; Kernforschungszentrum Karlsruhe G.m.b.H. (Germany, F.R.). Projekt Nukleare Sicherheit1981
AbstractAbstract
[en] The transition from slug to annular flow in horizontal air-water and steam-water flow was investigated. Test sections of 50; 66.6 and 80 mm ID were used. The system pressure was 0.2 and 0.5 MPa in the air-water experiments and 2.5; 5; 7.5 and 10 MPa in the steam-water experiments. For flow pattern detection local impedance probes were used. This method was compared in a part of the experiments with differential pressure and gamma-beam measurements. The flow regime boundary is shifting strongly to smaller values of the superficial gas velocity with increasing pressure. Correlations from literature fit unsatisfactorily the experimental results. A new correlation is presented. (orig.)
[de]
Es wurde der Uebergang von der Schwall- zur Ringstroemung in horizontaler Luft-Wasser- sowie Dampf-Wasser-Stroemung untersucht. Teststrecken mit 50, 66,6 und 80 mm Innendurchmesser wurden verwendet. Der Systemdruck betrug 0,2 und 0,5 MPa bei den Luft-Wasser-Experimenten und 2,5; 5; 7,5 und 10 MPa bei den Dampf-Wasser-Experimenten. Zur Bestimmung der Stroemungsform wurden lokale Impedanzsonden verwendet. Diese Methode wurde in einem Teil der Versuche mit Differenzdruck- und Gamma-Strahl-Messungen verglichen. Die Grenze zwischen den beiden Stroemungsformen verschiebt sich mit zunehmendem Druck wesentlich zu kleineren Werten der Gasvolumen-Stromdichte (superficial gas velocity). Aus der Literatur bekannte Korrelationen stimmen nur unbefriedigend mit den Experimenten ueberein. Eine neue Korrelation wird vorgeschlagen. (orig.)Primary Subject
Source
Nov 1981; 43 p
Record Type
Report
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Primary Subject
Source
p. 1.61-1.64; 1970; American Nuclear Society; Hinsdale, Ill; 5. annual intersociety energy conversion engineering conference; Las Vegas, Nev; 21 Sep 1970
Record Type
Book
Literature Type
Conference
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Original Title
Dosisverteilungen und Bestrahlungstechnik bei der Strahlenbehandlung des Mammakarzinoms im Stadium I
Primary Subject
Secondary Subject
Source
8 figs.; 1 tab.; 14 refs.
Record Type
Journal Article
Journal
Strahlentherapie; v. 149(1); p. 29-40
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Further to the description of the stationary-field irradiation with ultra-hard X-radiation (first communication) the planning of a moving field therapy is now discussed. The authors give simple criteria how to choose as exactly as possible the dose distribution adequate to the clinical plan among the available isodose plots. The indication of the necessary equipment parameters is facilitated by an irradiation table containings the average length of the moving beam. Test measures taken since 1974 on the linear accelerator Philips SL 75/10 show how good the scanning of a certain sector is reproducible. (orig.)
[de]
Anknuepfend an die Beschreibung der Stehfeldtechnik mit ultraharter Roentgenstrahlung (I. Mitteilung) wird nun der Ablauf der Bewegungsbestrahlungsplanung diskutiert. Dabei werden einfache Kriterien angegeben, wie unter den vorhandenen Isodosenplaenen moeglichst zielsicher die auf den klinischen Plan passende Dosisverteilung greifbar ist. Eine auf die mittlere Fahrstrahllaenge abgestimmte Bestrahlungstabelle erleichtert die Angabe der fuer die Durchfuehrung notwendigen Geraeteparameter. Wie gut reproduzierbar ein bestimmter Winkelbereich ueberstrichen wird, laesst sich aus den seit 1974 am Linearbeschleuniger Philips SL 75/10 laufenden Testmessungen erkennen. (orig.)Original Title
Dosimetrie am Linearbeschleuniger
Primary Subject
Secondary Subject
Record Type
Journal Article
Journal
Strahlentherapie; ISSN 0039-2073; ; v. 156(12); p. 818-823
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
No abstract available
Original Title
Entwicklung und Anwendung einer Programmroutine zur Ausgabe von berechneten und gemessenen Dosisverteilungen
Primary Subject
Source
10 figs.; with refs.
Record Type
Journal Article
Journal
Strahlentherapie; v. 142(3); p. 312-321
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Commercial silicon photo-elements were iradiated with 8 MV X-rays and 10 MeV electrons in the linear accelerator SL 75/10, and their usability as monitors and dosemeters was examined. The short circuit current of the photo-elements, which is linear to the transmitted dose rate, was measured with an expressly developed impulse amplifier which is sensitive to electricity. Further examinations as to the energy dependence proved a nearly constant sensitivity within the scope of 1 to 10 MeV. However, there are irradiation damages within this scope, which lead to a decrease of the sensitivity to photo-electricity producing a degeneration rate of 100 to 9 M Gy1. The examination showed on the other hand that, because of their simple measuring principle, the easily reproducible results, and the high sensitivity, the photo-elements can find various applications as monitors with direct display for relative measurements. (orig.)
[de]
Es wurden kommerzielle Si-Photoelemente an dem Linearbeschleuniger SL 75/10 mit 8 MW-Roentgenstrahlung und 10 MeV-Elektronen bestrahlt und ihre Verwendbarkeit als Monitore und Dosimeter untersucht. Der Kurzschlussstrom der Photoelemente, der linear zur uebertragenen Energiedosisleistung ist, wurde mit einem eigens dazu entwickelten stromempfindlichen Impulsverstaerker gemessen. Weitere Untersuchungen ueber die Energieabhaengigkeit ergaben im Bereich zwischen 1 und 10 MeV eine nahezu konstante Empfindlichkeit. Allerdings treten hier Strahlenschaeden auf, die zur Abnahme der Photostromempfindlichkeit mit einer Degenerationsrate von 100 bis 9 M Gy1 fuehren. Die Untersuchungen zeigten jedoch, dass sich die Photodioden als direktanzeigende Monitore fuer Relativmessungen wegen ihres einfachen Messprinzips, der guten Reproduzierbarkeit und der hohen Empfindlichkeit vielseitig einsetzen lassen. (orig.)Original Title
Nachweis ultraharter Roentgenstrahlung mit Silizium-Photoelementen
Primary Subject
Record Type
Journal Article
Journal
Strahlentherapie; ISSN 0039-2073; ; v. 156(12); p. 824-827
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The authors present a method allowing to dose a whole-body irradiation in such a way that a nearly homogenous dose of 10 Gy is reached in the whole patient, with the exception of the lung which shall only receive 8 Gy. Particular attention is given to be increased dose in the head and neck region caused by the smaller thickness as compared to the trunk, which is compensated by shields. The measurements were taken in a plastic phantom for all possible patient's dimensions. All necessary basic data are stored in a program which calculates the monitor preselection for the individual fields after input of the patient's dimensions. Further controls are intended in the near future by in-vivo measurements. The time necessary for the described measurements is about four to six days, and the same time has to be appended for the evaluation and establishment of program. (orig.)
[de]
Es wird ein Verfahren zur Dosierung einer Ganzkoerperbestrahlung vorgestellt, das zum Ziel hat, im gesamten Patienten eine moeglichst homogene Dosis von 10 Gy zu erreichen, mit Ausnahme der Lunge, der nur 8 Gy appliziert werden sollen. Insbesondere wird darauf geachtet, dass die Dosisueberhoehung an Kopf und Hals infolge der geringeren Dicke im Vergleich zum Rumpf durch Abschirmung kompensiert wird. Die Messungen wurden an einem Kunststoffphantom fuer alle praktisch vorkommenden Patientenabmessungen durchgefuehrt. Saemtliche erforderlichen Basisdaten sind in einem Programm gespeichert, das nach Eingabe der Patientenabmessungen unmittelbar die fuer die einzelnen Felder erforderlichen Monitorvorwahlen errechnet. Weitere Kontrollen des Verfahrens durch In-vivo-Messungen sind in naechster Zukunft beabsichtigt. Der Zeitaufwand fuer die nach dem beschriebenen Verfahren erforderlichen Messungen betraegt ca. 4 bis 6 Tage, wobei zur Auswertung und Erstellung des lauffertigen Programms noch einmal der gleiche Zeitraum anzusetzen ist. (orig.)Original Title
Dosimetrie einer Ganzkoerperbestrahlung zur Knochenmarktransplantation
Primary Subject
Secondary Subject
Source
Record Type
Journal Article
Journal
Strahlentherapie; ISSN 0039-2073; ; v. 158(9); p. 541-545
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Measurements of the spectral distribution of X-rays using a Si(Li)-detector form the basis for an investigation into contrast values provided by molybdenum and tungsten tubes in mammography. In order to evaluate contrast, the intensity of the characteristic radiation and of the brems rays were related to anode kV and thickness of section; the spectral intensity was then calculated for small calcium inclusions in soft tissues. For average tissue thickness (4 cm.) and an anode working at 30 kV, the molybdenum tube with a molybdenum filter is significantly better than a tungsten tube. With increasing size of breast, hardening of the radiation also increases, until for practical purposes contrast is determined by the brems rays alone. At this stage there is only little difference between the molybdenum and tungsten spectrum, and in the resultant contrast. (orig.)
[de]
Messungen der spektralen Verteilung der Roentgenstrahlung mit einem Si(Li)-Halbleiterdetektor bilden die Basis fuer Untersuchungen des Strahlenkontrasts bei Verwendung von Mo- bzw. W-Roehren in der Mammographie. Fuer die Kontrastbeurteilung wird die Intensitaet der charakteristischen Strahlung und der Bremsstrahlung als Funktion der Anodenspannung und Schichtdicke untersucht und ueber ein Rechenprogramm in die spektrale Intensitaet fuer eine kleine Kalkeinlagerung in Weichteilgewebe umgerechnet. Bei mittleren Schichtdicken (4 cm) und Anodenspannungen um 30 kV ist die Mo-Roehre mit Mo-Filter der W-Roehre klar ueberlegen, waehrend mit zunehmender Groesse der Mamma schliesslich die Aufhaertung der Strahlung so stark ist, dass praktisch nur noch der Bremsstrahlungsanteil den Kontrast bedingt. Hier unterscheiden sich dann Mo- und W-Spektrum und somit auch der erzielbare Kontrast kaum noch. (orig.)Original Title
Untersuchungen zum Strahlenkontrast in der Mammographie
Primary Subject
Record Type
Journal Article
Journal
Fortschritte auf dem Gebiete der Roentgenstrahlen und der Nuklearmedizin; ISSN 0015-8151; ; v. 135(2); p. 204-209
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The authors presents a Cerenkov threshold detector consisting of elements originating from the commercial vacuum industry. This detector allows to measure electron energies between 8 MeV and 20 MeV. By comparison of the signals of two photo-multipliers, a considerable independence of external disturbing factors is achieved. It is demonstrated that the results achieved with normal propane are not worse than those of super-purified gas and, therefore, a cheap and simple method is available in order to control the electron energy of accelerators. (orig.)
[de]
Es wird ein Schwellenwert-Cerenkov-Detektor aus Bauteilen kommerzieller Vakuumtechnik vorgestellt, der eine Messung von Elektronenenergien im Bereich zwischen 8 MeV und 20 MeV ermoeglicht. Durch den Vergleich der Signale zweier Photomultiplier wird eine weitgehende Unabhaengigkeit von aeusseren Stoereinfluessen erreicht. Es wird gezeigt, dass handelsuebliches Propan gegenueber dem hochgereinigten Gas keine schlechteren Ergebnisse liefert und somit ein preiswertes und in der Handhabung einfaches Verfahren zur Ueberwachung der Elektronenenergien von Beschleunigern zur Verfuegung steht. (orig.)Original Title
Ein Cerenkov-Detektor zur Energiebestimmung an Elektronenbeschleunigern
Secondary Subject
Record Type
Journal Article
Journal
Strahlentherapie; ISSN 0039-2073; ; v. 156(10); p. 697-702
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
1 | 2 | 3 | Next |