AbstractAbstract
[en] Purpose: The aim of this study was to measure the dose profile and output factors with a CyberKnife accelerator using a TM60019 microDiamond detector and a 1000SRS liquid chamber array (both PTW Freiburg, Germany). Methods: An MP3 water phantom (PTW, Freiburg) was positioned along the robotic world coordinate system. The TM60019 detector was adjusted to the center of the according fields and the semiconductor axis was aligned with the beam direction. Profiles at 5cm water depth and SSD = 80 cm were measured along the robotic x axis and y axis for the cylindrical collimators of the CyberKnife (diameter 60, 50, 40, 30, 20, 15, 12.5, 10, 7.5 and 5mm). To determine the output factors the dose profile was measured at 0.1 mm steps around the field center to find the maximum dose value. The liquid chamber array (1000SRS) measurement was performed with the same setup, but with RW3 buildup. Results: The 1000SRS measurements closely conform with the TM60019 profile measurement in all profile regions and for all collimator sizes. The profile measurement is influenced by the almost equal spatial resolution of the TM60019 detector (radius of the sensitive area 1.1mm) and of the 1000SRS liquid chamber array (single chamber width 2.3mm). The measured dose profiles have not been corrected for this limited spatial resolution. Rather we purpose to consider that spatial dose averaging over 2 mm wide regions might be justified in view of patient positioning inaccuracies and of the spaces in tissue participating in the biological radiation responses. Conclusion: The 1000SRS data points conform with the TM60019 profile measurements at all profile regions showing the applicability of liquid ion chamber arrays with the CyberKnife system
Primary Subject
Source
(c) 2014 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
External URLExternal URL
AbstractAbstract
[en] Purpose: The aim of this study is the measurement of the lateral response function of microDiamonds by comparison with radiochromic film dose measurement. In this study a TM60019 microDiamond (PTW Freiburg, Germany) and a prototype synthetic diamond detector with smaller sensitive volume were investigated. Methods: Two lead blocks were positioned below the gantry head of an Elekta Synergy accelerator using a gantry mount. Between the blocks two sheets of paper were fixed. The water phantom was positioned below the gantry mount, so that the block to water distance was 20 cm. The gap beam profile was measured at 5 cm water depth by radiochromic EBT3 film and diamond detectors. The film was fixed on a RW3 plate, moved by the step motor system of the phantom and digitized by an Epson 10000XL scanner using the red color channel. Results: The lateral response of the prototype diamond detector is comparable to that of film measurements, i.e. has negligible width. This corresponds to the small detector volume of the prototype detector. In contrast to this the FWHM values of the gap-beam dose profiles measured with the TM60019 detector are somewhat larger, which corresponds to the larger sensitive detector volume. Conclusion: This study has illustrated the high spatial resolution of the diamond detectors. In comparison with filmmeasured narrow-beam dose profiles, the TM60019 has a spatial resolution function of about 2 mm FWHM, whereas the FWHM for the prototype is practically negligible. However due to the low signal caused by the small sensitive volume, measurements with the prototype in clinical routine are a challenge. On the other hand the TM60019 is a good compromise between detector volume and signal output and thus a well suited detector for most clinically relevant small field situations
Primary Subject
Secondary Subject
Source
(c) 2014 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
External URLExternal URL
AbstractAbstract
[en] Purpose: In this study the dosimetric properties of the Octavius Detector 1500 array (PTW-Freiburg-Germany) are investigated. Methods: The chambers of the array, each with an entrance window of 4.4 × 4.4 cm2, are arranged in a checkerboard pattern in a measurement area of 27 × 27 cm2 with a sampling frequency of 0.1 mm−1 along each row which can be doubled by merging two measurements shifted by 5 mm. Linearity, stability and output factors were measured with either a Semiflex 31013 or 31010 as a reference detector. Output factors were additionally measured with a Diode 60012. The effective point of measurement was determined by comparing TPR curves of the array with Roos chamber 34001 measurements. The lateral dose response function of a single chamber was determined by comparison with a high resolution diode. An IMRT field verification was carried out with a merged OD1500 measurement. Results: The OD1500 was stable within ±0.15 %. Deviations in linearity did not exceed 1% from 5 to 1000 MU. The effective point of measurement was 8.2 mm below the surface. Deviations in output factors were below 0.77 % from 5 × 5 to 27 × 27 cm2. As expected for the smallest field of 1 × 1 cm2, the deviation from the diode was significant. The widths of the lateral dose response functions were σ6 = (2.07 ± 0.03) mm and σ15 = (2.09 ± 0.03) mm. Gamma Index passing rates for typical IMRT and VMAT plans were above 90 % compared to film and TPS calculations for a local 3 mm / 3 % criterion. Conclusion: The first measurements with the OD1500 array show the excellent applicability of the array for clinical dosimetry. The response of the array to the mean photon energy and dose per pulse are under investigation
Primary Subject
Source
(c) 2014 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
External URLExternal URL
AbstractAbstract
[en] Purpose: In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated.Methods: Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluated using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles.Results: The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the Gaussian dose response function for a single detector of the array were found to be (0.72 ± 0.25) mm at 6 MV and (0.74 ± 0.25) mm at 15 MV and the corresponding low pass cutoff frequencies are 0.22 and 0.21 mm−1, respectively. For the inner 5 × 5 cm2 region and the outer 11 × 11 cm2 region of the array the Nyquist theorem is fulfilled for maximum sampling frequencies of 0.2 and 0.1 mm−1, respectively. An IMRT field verification with a Gamma-Index analysis yielded a passing rate of 95.2% for a 3 mm/3% criterion with a TPS calculation as reference.Conclusions: This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields
Primary Subject
Secondary Subject
Source
(c) 2013 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
External URLExternal URL
Stelljes, T. S.; Looe, H. K.; Chofor, N.; Poppe, B.; Harmeyer, A.; Reuter, J.; Harder, D., E-mail: tenzin.s.stelljes@uni-oldenburg.de2015
AbstractAbstract
[en] Purpose: The dosimetric properties of the OCTAVIUS Detector 1500 (OD1500) ionization chamber array (PTW-Freiburg, Freiburg, Germany) have been investigated. A comparative study was carried out with the OCTAVIUS Detector 729 and OCTAVIUS Detector 1000 SRS arrays. Methods: The OD1500 array is an air vented ionization chamber array with 1405 detectors in a 27 × 27 cm2 measurement area arranged in a checkerboard pattern with a chamber-to-chamber distance of 10 mm in each row. A sampling step width of 5 mm can be achieved by merging two measurements shifted by 5 mm, thus fulfilling the Nyquist theorem for intensity modulated dose distributions. The stability, linearity, and dose per pulse dependence were investigated using a Semiflex 31013 chamber (PTW-Freiburg, Freiburg, Germany) as a reference detector. The effective depth of measurement was determined by measuring TPR curves with the array and a Roos chamber type 31004 (PTW-Freiburg, Freiburg, Germany). Comparative output factor measurements were performed with the array, the Semiflex 31010 ionization chamber and the Diode 60012 (both PTW-Freiburg, Freiburg, Germany). The energy dependence of the OD1500 was measured by comparing the array’s readings to those of a Semiflex 31010 ionization chamber for varying mean photon energies at the depth of measurement, applying to the Semiflex chamber readings the correction factor kNR for nonreference conditions. The Gaussian lateral dose response function of a single array detector was determined by searching the convolution kernel suitable to convert the slit beam profiles measured with a Diode 60012 into those measured with the array’s central chamber. An intensity modulated dose distribution measured with the array was verified by comparing a OD1500 measurement to TPS calculations and film measurements. Results: The stability and interchamber sensitivity variation of the OD1500 array were within ±0.2% and ±0.58%, respectively. Dose linearity was within 1% over the range from 5 to 1000 MU. The effective point of measurement of the OD1500 for dose measurements in RW3 phantoms was determined to be (8.7 ± 0.2) mm below its front surface. Output factors showed deviations below 1% for field sizes exceeding 4 × 4 cm2. The dose per pulse dependence was smaller than 0.4% for doses per pulse from 0.2 to 1 mGy. The energy dependence of the array did not exceed ±0.9%. The parameter σ of the Gaussian lateral dose response function was determined as σ6MV = (2.07 ± 0.02) mm for 6 MV and σ15MV = (2.09 ± 0.02) mm for 15 MV. An IMRT verification showed passing rates well above 90% for a local 3 mm/3% criterion. Conclusions: The OD1500 array’s dosimetric properties showed the applicability of the array for clinical dosimetry with the possibility to increase the spatial sampling frequency and the coverage of a dose distribution with the sensitive areas of ionization chambers by merging two measurements
Primary Subject
Secondary Subject
Source
(c) 2015 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA)
Record Type
Journal Article
Journal
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
External URLExternal URL