Ji Changsong; Zhang Shulan; Zhang Shuheng
Proceedings of the 4th national conference on nuclear monitoring1999
Proceedings of the 4th national conference on nuclear monitoring1999
AbstractAbstract
[en] Based on monitoring results of delayed neutrons from reactor first circle water, the leakage of reactor fuel elements is monitored. A monitoring equipment consisted of an array of 3He proportional counter tubes with 75 s delay has been developed. The neutron detection efficiency of 6.1% is obtained
Primary Subject
Source
China Electronics Socity, Beijing (China). Nuclear Electronics and Nuclear Detection Techneques Subsocity; China Nuclear Socity, Beijing (China). Nuclear Electronics and Nuclear Detection Techneques Subsocity; 193 p; 1999; p. 116-118; 4. national conference on nuclear monitoring; Kunming (China); 17-22 Oct 1999; Available from China Nuclear Information Center
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Ji Changsong; Zhang Shulan; Zhang Shuheng
Proceedings of 8. national conference on nuclear electronic and nuclear detection technology: Pt.11996
Proceedings of 8. national conference on nuclear electronic and nuclear detection technology: Pt.11996
AbstractAbstract
[en] Based on the characteristics of 6Li glass scintillator which is sensitive to both neutron and gamma rays, and 7Li glass scintillator which is sensitive to gamma rays only, a new method of detecting weak neutron flux under interference of strong gamma radiation has been investigated by means of 6Li-7Li pair glass scintillator gamma compensation method. The result of neutron flux measurement by above-mentioned method with an error of about 1% when the gamma ray interference is up to 18.7% has been obtained
Source
China Electronics Society, Beijing (China); Chinese Nuclear Society, Beijing, BJ (China); 348 p; 1996; p. 218-222; 8. national conference on nuclear electronics and nuclear detection technology; Zhuhai, GD (China); 2-7 Dec 1996; Available from China Nuclear Information Centre
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Guo Jingru; Li Hui; Zhang Shengdong; Cui Anzhi; Li Daming; Zhang Shulan
China institute of atomic energy annual report (1996)1997
China institute of atomic energy annual report (1996)1997
AbstractAbstract
No abstract available
Primary Subject
Source
China Inst. of Atomic Energy, Beijing (China); 180 p; ISBN 7-5022-1791-6; ; 1997; p. 112-113
Record Type
Book
Country of publication
ACTINIDE NUCLEI, ACTIVATION ANALYSIS, ALPHA DECAY RADIOISOTOPES, BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, CESIUM ISOTOPES, CHEMICAL ANALYSIS, EVEN-EVEN NUCLEI, EVEN-ODD NUCLEI, HEAVY NUCLEI, INTERMEDIATE MASS NUCLEI, INTERNAL CONVERSION RADIOISOTOPES, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, MATERIALS, MINUTES LIVING RADIOISOTOPES, NUCLEAR REACTION YIELD, NUCLEAR REACTIONS, NUCLEI, ODD-EVEN NUCLEI, RADIOACTIVE MATERIALS, RADIOISOTOPES, RARE EARTH NUCLEI, SAMARIUM ISOTOPES, SPONTANEOUS FISSION RADIOISOTOPES, STABLE ISOTOPES, URANIUM ISOTOPES, YEARS LIVING RADIOISOTOPES, YIELDS
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Based on the characteristics of 6Li glass scintillator which is sensitive to both neutron and gamma rays, and 7Li glass scintillator which is sensitive to gamma rays only, a new method of detecting weak neutron flux under interference of strong gamma radiation has been investigated by mans of 6Li-7Li dual glass scintillator gamma compensation method. The result of neutron flux measurement by above-mentioned method with an error of about 1% when the gamma ray interference is up to 18.7% has been obtained
Record Type
Journal Article
Journal
Nuclear Electronics and Detection Technology; ISSN 0258-0934; ; v. 18(3); p. 182-186
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] Objective: To occumulatle experience of anti-infection treatment in acute radiation sickness (ARS) induced by medical treatment in order to provide beneficial help for victims of accidental of acute radiation sickness. Methods: The changes of peripheral blood indices, body temperature and clinical symptoms of 17 cases who were clinically irradiated with 6.0-7.2 Gy X-rays were observed both before peripheral blood stem cell transplantation(PBSCT) and after anti-infection treatment. Results: WBC count began to decrease to below 1 x 109/L from the 8th to 10th days after irradiation and maintained at row level for 4 days or for 13.3 days if the patients had not received rhG-CSF treatment. In 29.4% of patients the body temperature was higher than 38.5 degree C. After comprehensive enviromental protection and anti-infection treatment, all patients could successfully tide over the period of bone marrow depression without appearance of the typical critical phase of ARS. Conclusion: PBSCT and rhG-CSF treatment can reduce the time span for reconstruction of bone marrow. Comprehensive enviromental protection and combined anti-infection treatment are key points fm successful treatment. (authors)
Primary Subject
Source
3 figs., 6 refs.
Record Type
Journal Article
Journal
Chinese Journal of Radiological Medicine and Protection; ISSN 0254-5098; ; v. 26(1); p. 20-22
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
Ji Changsong; Xie Liangnian; Zhang Shulan; Zhang Shuheng
Proceedings of the 10th national conference on nuclear electronics and nuclear detection technology2000
Proceedings of the 10th national conference on nuclear electronics and nuclear detection technology2000
AbstractAbstract
[en] A new depth neutron moisture meter BH5047 has been developed. BH5047 neutron moisture meter is characterised by it is high sensitivity and used for sand water content measurement at concrete mixer. Calibration function is obtained by the Method of Least Squares. Linear correlation efficiency is as good as 0.9977
Primary Subject
Source
Chinese Nuclear Society and Chinese Electronics Society, Beijing (China). Nuclear Electroics and Nuclear Detection Technology Subcociety; 587 p; 2000; p. 275-276, 287; 10. national conference on nuclear electronics and nuclear detection technology; Chengdu (China); 7-12 Sep 2000; Available from China Nuclear Information Centre
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Ji Changsong; Zhang Shulan; Zhang Shuheng; Xie Liangnian
Proceedings of the 3th national conference on nuclear instrument2001
Proceedings of the 3th national conference on nuclear instrument2001
AbstractAbstract
[en] Cadmium ratio meter based on 3He proportional counter tube as neutron detector has been developed. The cadmium ratio of 8.9:1 for Am-Be neutron after 10 cm polyethene moderator has been obtained
Primary Subject
Source
Nuclear Electronics and Nuclear Detection Technology Society, Beijing (China); 282 p; 2001; p. 248-249; 3. national conference on nuclear instrument; Guilin (China); 20-24 Sep 2001; Available from China Nuclear Information Centre
Record Type
Miscellaneous
Literature Type
Conference; Numerical Data
Country of publication
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Ji Changsong; Dai Zhude; Xie Liangnian; Zhang Shulan; Zhang Shuheng
Proceedings of the '98 national conference on nuclear instrument1999
Proceedings of the '98 national conference on nuclear instrument1999
AbstractAbstract
[en] A high-sensitive equipment monitoring leakage of the reactor fuel elements has been developed. The delayed neutrons emitted from fission product-pioneer nucleus are monitored in the 1st circle water. An array of 3He proportional counter tubes is designed as a neutron detector for delayed neutrons, the detection geometry of which is near to 4π. In order to reduce the influence of interference factors the monitoring of fission product is carried out with 75s delay. The 87Br delayed neutron pioneer nucleus is chosen as a monitoring object. The neutron detection efficiency of the developed equipment is 6.1%, which is 3 times higher than one of all available advanced equipment of the same function both at home and abroad
Secondary Subject
Source
China Electronics Society, Beijing (China); Chinese Nuclear Society, Beijing (China); 172 p; 1999; p. 109-113; '98 National conference on nuclear instruments; Jiangyou, Sichuan (China); 16-23 Sep 1998; Available from China Nuclear Information Centre
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
BARYONS, BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, BROMINE ISOTOPES, COOLING SYSTEMS, DETECTION, ELEMENTARY PARTICLES, ENERGY SYSTEMS, FERMIONS, FISSION NEUTRONS, HADRONS, HYDROGEN COMPOUNDS, INTERMEDIATE MASS NUCLEI, ISOTOPES, MATERIALS, MEASURING INSTRUMENTS, NEUTRON DETECTORS, NEUTRONS, NUCLEI, NUCLEONS, ODD-EVEN NUCLEI, OXYGEN COMPOUNDS, PROPORTIONAL COUNTERS, RADIATION DETECTION, RADIATION DETECTORS, RADIOACTIVE MATERIALS, RADIOISOTOPES, REACTOR COMPONENTS, REACTOR COOLING SYSTEMS, SECONDS LIVING RADIOISOTOPES
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume
INIS IssueINIS Issue
Li Daming; Zhang Shulan; Tang Peijia; Liu Daming; Guo Jingru; Wang Xiuzhi; Cui Anzhi; Li Xueliang
China institute of atomic energy annual report 19901991
China institute of atomic energy annual report 19901991
AbstractAbstract
No abstract available
Primary Subject
Source
China Inst. of Atomic Energy, Beijing (China); 311 p; ISBN 7-5027-2171-1; ; 1991; p. 215-216; China Ocean Press; Beijing (China)
Record Type
Book
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] A direct method is developed to assay 90Sr-90Y in liquid radiowaste samples by Cherenkov counting without any chemical separation. Since the most interfering nuclides existing in liquid radiowaste have poor counting efficiencies, their Cherenkov contribution can be corrected by HPGe γ-spectrometry. The 90Sr-90Y contents are determined for 10 kinds of liquid radiowaste samples and radiochemically analyzed for comparison. The results show that this method is competent for most liquid radiowaste samples
Record Type
Journal Article
Journal
Country of publication
BETA DECAY RADIOISOTOPES, BETA-MINUS DECAY RADIOISOTOPES, DAYS LIVING RADIOISOTOPES, EVEN-EVEN NUCLEI, GE SEMICONDUCTOR DETECTORS, HOURS LIVING RADIOISOTOPES, HYDROGEN COMPOUNDS, INTERMEDIATE MASS NUCLEI, ISOMERIC TRANSITION ISOTOPES, ISOTOPES, LIQUID WASTES, MATERIALS, MEASURING INSTRUMENTS, NUCLEI, ODD-ODD NUCLEI, OXYGEN COMPOUNDS, RADIATION DETECTORS, RADIOACTIVE MATERIALS, RADIOISOTOPES, SEMICONDUCTOR DETECTORS, SPECTROSCOPY, STRONTIUM ISOTOPES, WASTES, WATER, YEARS LIVING RADIOISOTOPES, YTTRIUM ISOTOPES
Reference NumberReference Number