AbstractAbstract
[en] The present work presents results of computational and experimental simulations, in order to show the influence of angular sampling in the quality of SPECT images reconstructed with the Convolution Backprojection algorithm. Geometric deformations and contrast artifacts had been produced in the incomplete sampled images. The experimental images were sampled at 32 projections over 1800 and 64 projections over 3600. Attenuation correction was performed for images sampled over 3600. The coomputationally simulated images were sampled at both 64 and 128 projections over 3600. (author)
[pt]
O trabalho apresenta resultados de simulacoes computacionais e experimentais, mostrando a influencia da amostragem angular na qualidade das images de Tomografia Computadorizada por Emissao de Foton Unico, reconstruidas com o metodo de Retroprojecao por Convolucao. Constatou-se o aparecimento de artefatos de contraste e distorcoes geometricas nas images adquiridas com amostragem angular incompleta. Na simulacao experimental foram utilizadas amostragens de 32 projecoes em 1800 e 64 projecoes em 3600. Foi efetuada correcao de atenuacao nas imagens adquiridas em 3600. Na simulacao computacional foram utilizadas 64 e 128 projecoes em 3600. (autor)Original Title
Efeitos de amostragem angular no exame tomografico de perfusao miocardia com Tl-201
Primary Subject
Secondary Subject
Source
11. Brazilian Congress on Biomedical Engineering; Sao Paulo, SP (Brazil); 3-6 Sep 1989
Record Type
Journal Article
Literature Type
Conference
Journal
RBE, Caderno de Engenharia Biomedica; ISSN 0102-2644; ; v. 6(2); p. 22-29
Country of publication
LanguageLanguage
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] This paper describes an improvement on Stanton's original design. It combines an useful feature of the Ardran and Crooks method with the Staton method. The device employs a polyethylene reference block alongside adjacent copper wedges. To determine the kVp, the kVp test tool is placed over a conventional X-ray cassette containing a fresh sheet of film and an appropriate exposure is made at the kVp which one wishes to measure. We used two thicknesses of brass to test the sensitivity of the wedge to spectral changes. The results indicate that the device is useful for measuring kVp over the diagnostic X-ray range (45-110 kvp). (author)
[pt]
Descreve-se um melhoramento no equipamento de determinacao de potencial de pico (kVp) descrito por Stanton, empregando um bloco referente de polietileno. Para determinar a kVp, um instrumento teste de kVp e colocado em cima da camera de raio-X convencional. Usou-se duas espessuras de latao para testar a sensibilidade da cunha para mudancas espectrais. Os resultados indicam que o invento e util para medicoes de kVp na faixa (45-110 kVp) de diagnostico de raio-X. (C.G.C.)Primary Subject
Source
11. Brazilian Congress on Biomedical Engineering; Sao Paulo, SP (Brazil); 3-6 Sep 1989
Record Type
Journal Article
Literature Type
Conference
Journal
RBE, Caderno de Engenharia Biomedica; ISSN 0102-2644; ; v. 6(2); p. 46-52
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The expanding apllication of non-invasive techniques in the internal pathological diagnosis has resulted in the increasing diffusion of digital imaging equipments and systems. This growth has required knowledgze of activities relative to use, production and technologies of these products, searching for rationalization of investments, as well as the establishment of strategies and priorities to obtain capability in these activities. (author)
[pt]
A crescente aplicacao de tecnicas nao-invasivas no diagnostico de patologias internas, tem resultado no desenvolvimento e difusao dos produtos que incorporam tecnologia de processamento de imagens. Este crescimento solicita o conhecimento e caracterizacao das atividades afins a estes produtos, visando racionalizar os investimentos, bem como estabelecer estrategias e prioridades para capacitacao nestas atividades. (autor)Original Title
Tecnologia de processamento de imagens para diagnostico medico: caracterizacao dos produtos
Primary Subject
Source
11. Brazilian Congress on Biomedical Engineering; Sao Paulo, SP (Brazil); 3-6 Sep 1989
Record Type
Journal Article
Literature Type
Conference
Journal
RBE, Caderno de Engenharia Biomedica; ISSN 0102-2644; ; v. 6(2); p. 77-84
Country of publication
LanguageLanguage
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] This work present an alternative approach in order to reconstruct images with low signal to noise ratio. Basically it consist of smoothing projections taking into account that the noise is Poisson. These filtered projections are used to reconstruct the original image, applying direct Fourier method. This approach is compared with convolution back projection and EM (Expectation-Maximization). (author)
[pt]
O presente trabalho propoe uma alternativa para a reconstrucao de imagens com baixa relacao sinal/ruido. A abordagem consiste basicamente no 'alisamento' das projecoes dentro de um modelo de ruido Poisson, e reconstrucao pela aplicacao direta da transformada de Fourier nas projecoes filtradas. Foram realizadas comparacoes qualitativas e quantitativas com os metodos 'convolution back projection' e o metodo iterativo 'Estimation-Maximization (EM)'. (autor)Original Title
Tomografia em imagens com ruido poisson: pre-processamento das projecoes
Primary Subject
Source
11. Brazilian Congress on Biomedical Engineering; Sao Paulo, SP (Brazil); 3-6 Sep 1989
Record Type
Journal Article
Literature Type
Conference
Journal
RBE, Caderno de Engenharia Biomedica; ISSN 0102-2644; ; v. 6(2); p. 1-7
Country of publication
LanguageLanguage
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] A proposal is here presented in order to implement a Quality Assurance Program in Diagnostic Radiology, aiming at minimizing problems of excessive repetition radiographic explorations, which lead to film wasting, unnecessary exposure of pacients to X-ray and possible wearing out of the equioment. This program is useful in the cases of Institutions lacking financial resources for it is characterized by its simplicity, being also feasible for implementation with Brazilian equipment. (author)
[pt]
Esse trabalho apresenta uma proposta para implantacao de um Programa de Garantia de Qualidade em Radiodiagnostico, visando minimizar os problemas envolvidos nesses servicos, tais como, altos coeficientes de repeticao das exploracaoes radiograficas, que acarretam gastos inuteis com filmes, exposicao desnecessaria dos pacientes a radiacao e desgate do equipamento. Esse programa e viavel tambem para instituicoes com recursos financeiros limitados, por ser basico e possivel de ser realizado com equipamentos nacionais. (autor)Original Title
Proposta para implantacao de um programa de garantia de qualidade em radiodiagnostico
Primary Subject
Secondary Subject
Source
11. Brazilian Congress on Biomedical Engineering; Sao Paulo, SP (Brazil); 3-6 Sep 1989
Record Type
Journal Article
Literature Type
Conference
Journal
RBE, Caderno de Engenharia Biomedica; ISSN 0102-2644; ; v. 6(2); p. 127-130
Country of publication
LanguageLanguage
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] A new method to obtain one-dimensional map of ultrasonic wave speed is proposed. The method consists of insonifying a medium with an ultrasonic pulse and receiving the reflected echo on the same transducer used as transmitter and in another one placed adjacent. Each interface iluminated by the irradiated wave returns an echo to both transducers. Then by measuring the time-of-flight for each echo arrived on both transducers, the position of each interface, related to the transmitting transducer, and the wave speed existent between consecutive interfaces can be obtained. In the present work a phantom was made. Consisting of 3 layers: epoxi(9,9mm), acrilic (9.7mm) and pvc (10.2mm). The phantom was imersed in a tank filled with water, together with a holder with the 2 transducer in it. Using a digital osciloscope and microcomputer can implement the method proposed. The values calculated for the distancers interface-transducers have shown errors from 0.1% to and can be acceptable to a certain extent. On the other hand, all the obtained for the width of layers and for the of the US wave inside them are acceptable. The width of the of the echo from interface acrilic-pvc and it is necesary an exciting pulse with greater amplitude to enhance it. Results can be accepted as first approximation and encourage us to proceed exploring this method. (author)
[pt]
Propoe-se um novo metodo para se obter o mapeamento unidimensional da velocidade de ondas ultra-sonicas. O metodo consiste em se irradiar um meio com um puslo de ultra-som (US) e receber o eco no transdutor transmissor e em outro colocado ao lado deste. Tomando-se medidas do tempo de chegada de cada eco em ambos os transdutores, a posicao de cada interface que refletiu o pulso incidente e a velocidade da onda no meio entre duas interfaces consecutivas pode ser obtida. Construiu-se um corpo de prova consistindo de 3 camadas: epoxi, acrilico e pvc (espessuras: 9,9mm; 9,7mm e 10,2mm, respect.) O corpo de prova foi imerso em um tanque com agua, juntamente com o suporte com os 2 transdutores em pararelo. Utilizando-se um osciloscopio digital e um microcomputador pode-se fazer as medidas dos tempos de chegada e implementar o metodo. Os valores calculados para as distancias interface - transdutores apresentaram erros de 0,19% a 7,94% e sao considerados satisfatorios. Ja os valores obtidos para a espessura de cada camada e velocidade do US nas mesmas nao sao, de todo, satisfatorios. A espessura da camada de acrilico apresentou um erro grande. Isto e devido a baixa amplitude do eco proveniente da interface acrilico-pvc, sendo necessario, um puslo de excitacao de maior amplitude. Os resultados iniciais sao considerados satisfatorios em uma primeira aproximacao e encorajam a prosseguir explorando as potencialidades do metodo. (autor)Original Title
Proposta de um novo metodo para tomografia ultra-sonica por pulso-eco
Primary Subject
Source
11. Brazilian Congress on Biomedical Engineering; Sao Paulo, SP (Brazil); 3-6 Sep 1989
Record Type
Journal Article
Literature Type
Conference
Journal
RBE, Caderno de Engenharia Biomedica; ISSN 0102-2644; ; v. 6(2); p. 58-63
Country of publication
LanguageLanguage
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] This work describes a high resolution and accurate microcomputer controlled microdensitometer to collect and memorize data from radiological films. (author)
[pt]
O presente trabalho descreve um sistema digitalizador de alta resolucao e precisao comandado por microcomputador para a coleta e armazenamento de dados obtidos de filmes radiologicos. (autor)Original Title
Microdensitometro para analise de imagem
Primary Subject
Source
11. Brazilian Congress on Biomedical Engineering; Sao Paulo, SP (Brazil); 3-6 Sep 1989
Record Type
Journal Article
Literature Type
Conference
Journal
RBE, Caderno de Engenharia Biomedica; ISSN 0102-2644; ; v. 6(2); p. 330-335
Country of publication
LanguageLanguage
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] The present work describes the software under development for Image Processing and Visualization of MR Images. This project is part of Magnetic Ressonance Tomographic System which is being built at the IFQSC - USP
[pt]
No Instituto de Fisica e Quimica de Sao Carlos - USP, esta em desenvolvimento um tomografo que efetua a coleta de dados atraves da tecnica de Ressonancia Magnetica. Este trabalho apresenta o Sistema de Software que permite o Processamento e Visualizacao de Imagens obtidas dessa formaOriginal Title
Desenvolvimento de 'software' basico para o processamento e visualizacao de imagens tomograficas obtidas por RM
Primary Subject
Secondary Subject
Source
11. Brazilian Congress on Biomedical Engineering; Sao Paulo, SP (Brazil); 3-6 Sep 1989
Record Type
Journal Article
Literature Type
Conference
Journal
RBE, Caderno de Engenharia Biomedica; ISSN 0102-2644; ; v. 6(2); p. 116-122
Country of publication
LanguageLanguage
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] This work reports the development of measuring system of the peak potencial (KVp) applied to the X-ray tubes to use as a basic equipment to the Mammographic Units Quality Control. The device uses the scintillation detection process to determine KVp, and it's composed of a Na(Tl) crystal coupled to a photomultiplier tube, and of an eletronic circuit which does a proper signal treatment, showing the measured KVp value on displays. Based on the tests, it's clear that the developed equipment is in good agreement with the requirements to the mammography quality control due its adequate accuracy, and making the radiographic films useless for the evaluation of the results. (author)
[pt]
O presente trabalho trata do desenvolvimento de um sistema medidor do potencial de pico (KVp) aplicado num tubo de raios-X para ser utilizado como equipamento de apoio ao Controle de Qualidade em Unidades Mamograficas. O dispositivo se utiliza da deteccao de cintilacao para determinar a KVp, constituindo-se de um cristal de iodeto de sodio dopado com talio (NaI(Tl)), acoplado a uma fotomultiplicadora, e de um circuito eletronico que faz o adequado tratamento do sinal, amostrando o valor da KVp aferida e exibindo-se em 'displays'. Com base nos testes efetuados, verifica-se que o equipamento desenvolvido satisfaz muito bem os requisitos ao controle de qualidade em mamografia, pois possui grande precisao, descartando o emprego do filme radiografico na analise dos resultados. (autor)Original Title
Detector de cintilacao como medidor da KVp para o controle de qualidade em mamografia
Secondary Subject
Source
11. Brazilian Congress on Biomedical Engineering; Sao Paulo, SP (Brazil); 3-6 Sep 1989
Record Type
Journal Article
Literature Type
Conference
Journal
RBE, Caderno de Engenharia Biomedica; ISSN 0102-2644; ; v. 6(2); p. 71-76
Country of publication
LanguageLanguage
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue
AbstractAbstract
[en] This paper presents some characteristics of a graphics system that is being constructed in the Electronics Instrumentation and Computation Laboratory (LIE) of IFQSC. This system will be used in reconstruction and interpretation of MR tomographic images. A minimum system is at moment being used at our laboratory to visualize MR images. (author)
[pt]
Neste trabalho serao apresentadas as caracteristicas de um sistema grafico em desenvolvimento no LIE (Laboratorio de Instrumentacao Eletronica e Computacao) do IFQSC, que devera ser usada na reconstrucao e interpretacao de imagens obtidas por Tomografia por RM. Os sistema minimo ja foi desenvolvido no LIE e ja se encontra em operacao. (autor)Original Title
Sistema para visualizacao de imagem em tomografia por Ressonancia Magnetica (RM)
Primary Subject
Secondary Subject
Source
11. Brazilian Congress on Biomedical Engineering; Sao Paulo, SP (Brazil); 3-6 Sep 1989
Record Type
Journal Article
Literature Type
Conference
Journal
RBE, Caderno de Engenharia Biomedica; ISSN 0102-2644; ; v. 6(2); p. 123-126