[en] The ZTH reversed-field pinch to be installed in the Confinement Physics Research Facility (CPRF) will produce a significant ambient magnetic field. To avoid ground-loop and other electrical problems, the diagnostics in direct or possible contact with the experiment will be accessed through a fiber optic data way. The frequency-modulated analog links developed for this system have a bandwidth of dc to 100 kHz and a signal-to-noise ratio of better than 60 dB. The fiber optic transmitter units include a signal conditioner and a microprocessor controller. The conditioners can be configured as dc-coupled, low-noise differential amplifiers, or as high-gain, low-drift differential integrators with a very long droop time constant. Magnetic field pickup is minimized by balancing sensitive circuit areas to within 5 mm2 in all three planes of the PC boards. The gain, offset, and integrator reset are controlled and monitored by the microprocessor, and their status is displayed on the front panel of the transmitter unit. The signal conditioner can be controlled locally, or by way of a fiber optic coupled control network. The system allows fast, convenient, noise-immune control of a large number of signal conditioners from a central host computer. By varying the offset, the computer can verify the operational integrity of the data links. 2 refs., 6 figs
Primary Subject
Source
1989; 5 p; 13. international symposium on fusion engineering; Knoxville, TN (USA); 2-6 Oct 1989; CONF-891007--68; CONTRACT W-7405-ENG-36; Available from NTIS, PC A02/MF A01 as DE90002444; OSTI; INIS; US Govt. Printing Office Dep
Record Type
Report
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue