[en] A DC current transformer (DCCT) has been designed to operate over the current range of ± 20 mA, with a resolution and accuracy of 2 μA. The long term drift has been measured at less than 3 μA over 30 hours. A test has been done using H- beam CRM 2-inch cusp ion source to compare the readings of DCT and the Faraday Cup. The test shows that they both agree within 3 μA. (author)
Primary Subject
Source
Jul 1992; 3 p; 13. International conference on cyclotrons and their applications, (Cyclotrons '92); Vancouver, British Columbia (Canada); 6-10 Jul 1992; Available from TRIUMF, Vancouver, British Columbia (Canada); 1 ref., 4 figs.