Estimation of Common Cause Failure Parameters for Emergency Service Water System Pump of Kori Unit 2
Kang, Dae Il; Hwang, Mee Jung; Han, Sang Hoon; Park, Jin Hee
Proceedings of the KNS autumn meeting2010
Proceedings of the KNS autumn meeting2010
AbstractAbstract
[en] The probabilistic safety assessment (PSA) results for Kori Unit 2 showed that the common cause failure (CCF) events of emergency service water system (ESWS) pump failure to run were identified as one of the dominant contributors to its internal event core damage frequency (CDF). The generic values of the CCF parameters were used in PSA projects for the Kori Unit 2. Thus, we performed the plant specific detailed CCF analysis to estimate the CCF parameters of ESWS pump failure to run for Kori Unit 2 with the CAFE-PSA(common CAuse Failure Event analysis program for PSA), a program to analyze CCF events in the ICDE database
Primary Subject
Source
Korean Nuclear Society, Daejeon (Korea, Republic of); [1 CD-ROM]; May 2010; [2 p.]; 2010 spring meeting of the KNS; Pyongchang (Korea, Republic of); 27-28 May 2010; Available from KNS, Daejeon (KR); 7 refs, 3 tabs
Record Type
Miscellaneous
Literature Type
Conference
Country of publication
Descriptors (DEI)
Descriptors (DEC)
Reference NumberReference Number
Related RecordRelated Record
INIS VolumeINIS Volume