AbstractAbstract
[en] A method has been developed to optimally and automatically determine the adjustable parameters of the boiling water reactor three-dimensional core simulator FLARE. The steepest gradient method is adopted for the optimization. The parameters are adjusted to best fit the operating data on power distribution measured by traversing in-core probes (TIP). The average error in the calculated TIP readings normalized by the core average is 0.053 at the rated power. The k-infinity correction term has also been derived theoretically to reduce the relatively large error in the calculated TIP readings near the tips of control rods, which is induced by the coarseness of mesh points. By introducing this correction, the average error decreases to 0.047. The void-quality relation is recognized as a function of coolant flow rate. The relation is estimated to fit the measured distributions of TIP reading at the partial power states
Primary Subject
Record Type
Journal Article
Journal
Nuclear Technology; v. 27(3); p. 315-326