1961 Volume 39 Issue 3 Pages 97-102
In normal dew-point practice, we take the conventional assumption that the vapour pressure gradient in the layer near the cooled surface is zero. But we know a concentration gradient is set up as the result of the nonuniformity of the temperature. In the present note, the magnitude of the vapour pressure gradient is theoretically estimated.