Hepta Insights’ Post

🔍 It’s time for the Spot the Defect challenge! Take a close look and let us know in the comments where you think the defect is hiding! 🤔 Hint: This type of issue is difficult to spot from ground level, but drones make it possible. #PowerLineInspection #DroneTechnology #InspectionChallenge #UtilityInspection #DefectDetection #InfrastructureSafety

  • No alternative text description for this image
FRANCISCO MIÑANA

Unmanned Aerial Systems Pilot Coordinator STS 01-02 Endesa Engineering-RPR MT BT Technical Inspector - Topography

1mo

Cabezas de aisladores cerámicos con los extremos superiores partidos, fijaciones dobladas y tornillería oxidada. Claro ejemplo de apoyos que siendo de alineación la fuerza de los extremos les hace “ahorcar” los elementos de fijación aislante . Ceramic pin insulator heads with upper split ends ,bent fixings And rusty screws Clear example of supports that, being aligned, the force of the ends causes them to “hang” the insulating fixing elements.