SLC brands LCMF series Measuring gratings and measuring systems * 3 scanning methods: Straight scan. Single-edge scan. Double- edge scan * Detection accuracy: 2.5mm/5mm/10mm (Depending on scan mode) * 20 measurement ( "scan analysis" ) modes *3 output modes: 2-way independent level output, 2-way independent analog output, standard Modbus 485 RTU serial output
Lesley O’s Post
More Relevant Posts
-
Smart - Fast - Digital (Ethernet APL used by iTEMP TMT86 transmitting temperature with profinet) by Endress Hauser. Integrated Functions 1. Push In Terminals 2. Diagnostic Monitoring a. Corrosion Monitoring of sensor wires b. Device Hardware Fault Recognition c. Sensor drift detections d. Sensor back up function
To view or add a comment, sign in
-
Measurand created the Portable Diagnostic Unit (PDU) in order to offer clients a convenient and cost-effective means of verifying the patented cyclical installation of SAAV. This ensures that your ShapeArray is able to provide the most accurate deformation data possible. Acting as an interface, the PDU manages the communication and power between the ShapeArray and the computer. It is equipped with a high-quality DC to DC converter that boosts and regulates the voltage from the 10.80V Lithium-Ion battery to a constant 13.5V. The PDU also has the capability to increase the voltage to 16.5V, allowing for the use of longer communication cables. With a rapid charging battery, the PDU can fully charge in just 105 minutes. Its USB-C connectivity enables both communication and power to be supplied through a single input. Add to your ShapeArray today: https://loom.ly/1JcUCgU #measurand #shapearray #portablediagnosticunit #accessories #interface #pdu #geotechnicalinstrumentation #learnmore
To view or add a comment, sign in
-
P30U Digital Panel Meter Rail Mount Data logger Transducer Input: Universal - V d.c, mA, RTD, mV, T/C, RS485 Modbus Master or Monitor Output: 4...20mA or 0...10Vdc, Ethernet
To view or add a comment, sign in
-
After launching the lightweight integrated bus temperature transmitter, we have now introduced the split-type bus temperature transmitter with 485 signal output. This product is easy to install, has stable performance, and offers good consistency. 1. Input signal: 1 Pt100 input 2. Operating voltage: 9 to 30 VDC 3. Output signal: 1 RS485 serial communication output 4. Communication protocol: standard MODBUS protocol 5. Serial port parameters: 9600, n, 8, 1 6. Accuracy: ±0.2%FS; resolution 0.1℃ 7. Range: -50℃ to 300℃ (customizable) 8. Temperature drift: ±0.1℃/year 9. Operating temperature: -40℃ to +80℃ 10. Storage temperature: -40℃ to +80℃ 11. Protection rating: IP68, IP65 Specifications and installation methods of the probe part can be customized according to customer requirements. Various types of plugs can be installed on the tail end wiring as requested. The split-type bus temperature transmitter with 485 signal output is a non-standard product that can be customized as needed. Please feel free to inquire!
To view or add a comment, sign in
-
3/3) Practical Notes: Channel Configuration: Configure ADC channels in the MCAL layer based on the hardware connections. Scaling and Calibration: Use physical calibration data (e.g., sensor-specific equations) to scale raw ADC values. Interrupt vs. Polling: Use interrupts for high-priority ADC conversions. Polling can be used for non-critical ADC data. Fault Handling: Implement fault detection for scenarios like sensor disconnection or ADC errors.
To view or add a comment, sign in
-
EMI/EMC tested Modbus TCP remote IO module IOy series with 8DI 16DO 1RS485 RTD TC sensor. 26 IO board options are available, which can be combined into more than 10,000 models to meet various application scenarios, and I/O modules can be selected according to physical interface, protocol and I/O function. https://lnkd.in/gn6tVcKX
BL190 Modbus TCP IOy Ethernet IO
bliiot.com
To view or add a comment, sign in
-
Digital logic, What Is Linear Voltage Regulator, High voltage linear regulator
LM317D2TR4G in Reel by onsemi | Linear Regulators | Future Electronics
futureelectronics.com
To view or add a comment, sign in
-
8 Channel Relay Output Module RS485 Modbus RTU DO Relay Module --- I/O modules monitor device status, communication errors, and fault conditions in sensors, actuators, and wiring connections. They provide diagnostic information and alarm signals to the control system for fault detection and troubleshooting. --- https://lnkd.in/gatjgM-P #digitalinputmodule #analoginputmodule #digitaloutputmodule #analogoutputmodule #relayoutputmodule #automationcontrol #dataacquisitionmodule #communicationmodule #industrialinputoutputmodule #lightingcontrolmodule
To view or add a comment, sign in
-
We designed bay controller MIO-8-4-i ( 8-DI, 4-RC, 1-ME). MIO-8-4-I is an autonomous unit that provides connection to the 8th discrete sensors with «dry contact» type, issuing two two-position discrete control commands (4 power switches), measurement of alternating current by one phase (0…1 or 0…5 A). Data exchange with external devices is supported by three communication channels with the RS-485 interface. Exchange protocol – Modbus (RTU) https://lnkd.in/dUGkTud5
To view or add a comment, sign in