BLYGOLD TREATMENT A PERMANENT SOLUTION FOR VRF/HVAC SYSTEM (ROI BASED FORMULATION)
WHAT IS A BLYGOLD TREAMTENT?
Blygold Treatment is a detail oriented Corrosion Protection treatment which is applied primarily on HVAC Air cooled Condensers’ copper piping and Aluminum Fins. The treatment incorporates two layers of coating on brand new air conditioning units. The first layer of coating is the rust penetrating and moisture curing Polyurethane primer that is applied on copper headers and returns of heat exchangers. It has 12 hours curing time and the top coating material is Aluminum Impregnated Polyurethane (POLU-AL XT or Blygold) which also takes around 6 hours to get cured. The treatment is not a conventional coating but it is a treatment which can protect air conditioning equipment from corrosion and make it leakage free particularly in different types of acetic/industrial/corrosive/Coastal Environment.
Mostly in Karachi, Lahore and Faisalabad, the industrial gases/Sewerage/Chemicals around your industry makes sure that your unit will only survive for 2 to 3 yrs. without any protective treatment. Blygold makes sure that units will have at least doubled lifetime once it is applied on same unit in same acetic/corrosive environment without affecting the thermal efficiency much.
ABOUT BLYGOLD NETWORK
Blygold treatment is headquarter in Netherlands while regional head offices are also located in USA and Australia. Blygold has a worldwide global network in more than 75+ Countries. It is currently a market leader and the biggest Multinational chain in providing corrosion protection coatings on all kinds of residential/Light commercial/HVAC/Refrigeration Machines.
WHY YOU SHOULD CHOOSE BLYGOLD ON VRF SYSTEM?
Blygold saves a major maintenance cost being spent on all HVAC Units incorporating VRF System and it also reduces the chances of early unit replacement by not only prolonging its lifetime upto three times but also preventing it from corrosion and copper coil leakages a big time. Let’s calculate the maintenance cost being spent on yearly basis for a 10 to 15 ton VRF Unit and we’ll compare the total maintenance cost with Blygold Treatment Cost.
In any industrial environment, the unit leakage frequency is 3 to 4 times a year. Thus, following will be the one time cost on VRF Leakage repair and Gas filling.
Refrigerant Cost (15 to 20 KG): 76,000/-
2 Nitrogen Cylinder (Flushing): 4000/-
Repair Charges: 30,000/-
Total: 110,000/- Rs. (For one time repair only)
Therefore, if unit is installed without treatment then estimated maintenance cost for three years will be as follows:
110,000 x 4 times (On average): 440,000/- (1 yr.)
110,000 x 12 times (on average): 1,320,000/- (3yrs)
Hence, without treatment the total maintenance expenses could be around 1,320,000/- to 1,350,000/- on a single VRF Outdoor besides the increased power consumption due to fins brittleness as well based on industrial Environment. Now, imagine the no of outdoor units you have installed at your site and the cost which would be spent on its maintenance on yearly basis. Believe me it would go in Millions of rupees just to make your system run smoothly with regular system shut downs and maintenance pauses. Thus, Blygold is a permanent solution to cope with this big challenge. The treatment is surely going to save your millions of rupees and will save you from sudden HVAC System Failure due to corrosion and leakages problems. A smart mind will never turn a blind eye to Blygold for sure due to its greater piece of efficacy and return to you.
RETURN ON INVESTMENT WITHING 6 MONTHS
Blygold treatment would cost around 130K to 150K on 15 ton VRF Outdoor Unit and Blygold will make sure that the treated unit will have no corrosion problems for at least 3 to 5 years and the chances of leakages drops significantly or will be no more. Therefore, considering the total 3 years cost, the return of investment will be made within 6 months to max an year followed by successful execution of Blygold Treatment.
BLYGOLD TREATMENT SERVICES WARRANTY
On brand new VRF condensers, blygold will give you 3 years corrosion protection services warranty however, on slightly older units (within 1 year) the service warranty will be half of it.
BLYGOLD PROJECTS:
1. Emaar Pakistan (York VRF)
Recommended by LinkedIn
2. Sanofi Aventis ( Bitzer condensing units)
3. Oncogen Pharma Korangi Industrial Park (Hi-sense/LG VRF)
4. Karachi Shipyard & Engineering Works ( Brand new Split units)
5. Japanese Consulate (Daikin Package unit)
6. S Abdullah Outlet DHA (Hi-sense VRF)
7. PIBT Port Qasim ( Gree VRF)
8. Adamjee Insurance Building I.I chundigarh Road Karachi (Gree VRF)
9. Standard Chartered Building I.I chundigarh Road Karachi ( Daikin VRV)
10. Allied Bank Multiple Branches Projects (Daikin VRV)
11. Atlas Honda Site Area (200 tons of York Chiller)
12. Systems Limited Lahore ( Gree VRF)
13. IDEAS Clifton Outlet(Hi-sense VRF)
14. Marine View Building Boat Basin (Hi-sense and Hitachi VRF)
15. .Forum Mall Clifton.(Hi-sense VRF)
16. Sameer chinoy Residence Clifton(Daikin VRV)
17. South Asia Pakistan Terminal( York VRF and Package Units)
18. Aisha Steel (Split Units)
19. Shafi Lifestyle Lahore ( Gree VRF)
20. Rasheed Textile Faisalabad ( Gree VRF)
21. Telenor Microfinance Bank Lahore (Gree VRF)
22. Grace Apparel Gizri Boulevard Office Khi ( Gree VRF)
23. Organic Meat Company Khi ( Emeron Refrigeration Units)
24. Commercial Office Building Khayaban-e-Shahbaz,D.H.A Karachi( Hitachi VRF)
25. Mcdonalds DHA Phase 8( Pearl Brand Package Unit) any many more.