CENTRIFUGAL PUMP RELIABILITY

CENTRIFUGAL PUMP RELIABILITY

General

Centrifugal pumps when properly applied, installed and when given reasonable care and maintenance, should operate satisfactorily for a long period of time. The following general principles should be considered to insure trouble free operation.

 Centrifugal pumps are built in a wide variety of designs and for many different services. The manufacturer’s instruction book should be followed, as there may be specific requirements for a particular machine or application, which cannot be covered in a general discussion.

 Location of Unit

The pump should be as near the liquid source as practical, either submerged or so that a short, direct suction pipe may be used. The pump should be located so that a short, direct discharge pipe, with the least number of elbows and fittings, may be used to minimize head loss due to friction. If practical it should be placed so that it will be accessible for inspection during operation. Pumps and drivers, other than submersible types, should be protected against flooding. Motor driven pumps installed in enclosed cabinets should have sufficient air circulation to prevent overheating of the motor during normal operation.

 Foundation

The pump mounting should be sufficiently rigid so as to absorb vibration and prevent undue stress at the inlet and outlet connections. If a shock absorber (flexible) mount is used then the inlet and outlet piping should provide for movement of the pump without placing undue stress on in and out connections and electrical connections.

Foundation of Pump


 Extending Operating Life

 Pump operating life is dependent on the operating conditions, product pumped, frequency of start/stops and site environment. If the pumped product is free of contaminants and does not change its characteristics over time pump life can be greatly extended. The least damaging operating parameters for a centrifugal pump are pumping clean, clear water at ambient temperature and not alternately starting and stopping the unit.

Defining this as “normal” operating conditions, the following generalizations can be made:

 1.  Under "normal" operating conditions the pump and motor should have a useful life of approximately 3 years or longer, with maintenance as noted in both the pump and motor Operating and Instruction Manual.

 2.  Start/stop cycles greatly reduce seal and bearing life due to the lack of lubrication at the seal during the initial start of the pump and the extra torque load on the bearings during startup.

3.  Above ambient product temperatures can adversely affect pump life by inducing cavitation, which can erode impeller surfaces. Fluctuations in operating temperatures can change the characteristics of the liquid pumped causing it to become corrosive (acidic) reducing the life of seals, gaskets and possibly materials of construction.

Some liquids used in the semiconductor industry such as DI water and glycol's can limit pump life if they are not kept clean and within defined ph levels. For example, ethylene glycol will become acidic over time when exposed to heat and oxygen. It is recommended the pumped product be filtered and checked for ph levels periodically (dependent on operating time). It may be necessary to change the fluid in chiller/wash systems on a scheduled interval or event, to prolong equipment life.

 4.  Abrasive particles in the pumped liquid greatly reduce seal life and can also adversely effect impeller and volute/diffuser by eroding high velocity surface areas.

 5.  Improper installation of piping, can induce stresses causing misalignment, fractures in suction or discharge ports or disrupt laminar flow to the suction port (causes cavitation).

 6.  Some small motor bearings require periodic lubrication. If the motor has an oiling cup or grease fitting, follow the manufacturers recommendation of oil/grease quality and frequency.


 It is recommended that a pump operated 24/7 be serviced at 12-18 month intervals to insure its reliability. The following service is recommended but may be modified based on the factors noted above:

 1.    Disassembled and inspect



Check condition of the volute/diffusers and impeller (s) for erosion or corrosion replace if necessary.

  • Replace seals, gaskets & bushings
  • Check motor shaft axial and radial movement. If excessive, replace motor bearings or motor.
  • Inspect suction and discharge connections threads or flanges for damage. Refinish or replace as needed.

2.  Re-assemble pump and motor in accordance with Operating and Instruction manual.

3.  Follow installation and startup procedures.

 Remember, a pump and its driver are pieces of machinery that require preventative maintenance to prolong their useful life. Proper operation and maintenance will insure long and trouble free operation.

Source : pricepump

To view or add a comment, sign in

More articles by Muhammad Shabbir Akhtar

  • The Essential Role of Oil Return Bends in Refrigeration Systems

    The Essential Role of Oil Return Bends in Refrigeration Systems

    Refrigeration systems are the backbone of many industries, providing the necessary cooling to preserve food, manage…

  • GAS PHASE FILTRATION SYSTEM

    GAS PHASE FILTRATION SYSTEM

    Gas phase filtration is a process that removes gaseous contaminants from the air using adsorbents, chemisorbents, or a…

  • NH3/CO2 cascade refrigeration system

    NH3/CO2 cascade refrigeration system

    Food storage is a complex issue that involves many biological factors that affect the quality and safety of food…

    1 Comment
  • TYPES OF HVAC INSULATIONS AND THEIR CHARACTERISTICS

    TYPES OF HVAC INSULATIONS AND THEIR CHARACTERISTICS

    HVAC insulations are essential for the energy performance of heating and cooling systems. They help to minimize heat…

  • Precision Air Conditioning for Server Rooms

    Precision Air Conditioning for Server Rooms

    Precision air conditioners were originally developed prior to the advent of PC’s when large main frame computers were…

  • Direct Fired Absorption Chillers Priciple and COP Calculations

    Direct Fired Absorption Chillers Priciple and COP Calculations

    Absorption chiller makes chilled water through the 4 cycles of “evaporation,” “absorption,” “generation,” and…

    1 Comment
  • Building De-carbonization

    Building De-carbonization

    Building de-carbonization is the process of reducing or eliminating the carbon dioxide emissions that contribute to…

  • Pumps

    Pumps

    Pumps are divided into two fundamental types based on the manner in which they transmit energy to the pumped media:…

  • Direct Air Capture

    Direct Air Capture

    #Direct Air Capture Direct air capture (DAC) is a technology that captures carbon dioxide (CO2) from the ambient air…

  • How to Answer The 64 Toughest Interview Questions

    How to Answer The 64 Toughest Interview Questions

    General Guidelines in Answering Interview Questions Everyone is nervous on interviews. If you simply allow yourself to…

    2 Comments

Insights from the community

Others also viewed

Explore topics