Common Causes of Flange Leakage & Benefits of Immediate Leak Detection

Common Causes of Flange Leakage & Benefits of Immediate Leak Detection

A previous article highlighted the primary causes of flange leakage. In this article I provide more information about these flange leak cause : 

  • Uneven Bolt Stress. An incorrect boltup procedure or cramped working conditions near the flange can leave some bolts loose while others are overtightened and crush the gasket. This can cause in-service leaks, especially in high temperature services when the heavily loaded bolts relax.
  • Improper Flange Alignment. Improper flange alignment, especially flange face parallelism, causes uneven gasket compression, local crushing, and can cause subsequent leakage. Improper flange centerline alignment can also cause uneven gasket compression and flange leaks.
  • Improper Gasket Centering. If a gasket is installed off center compared to the flange faces, the gasket will be unevenly compressed and make the joint prone to leakage. Spiral wound and double jacketed gaskets usually have a centering ring that extends to the inner edge of the bolts. A sheet gasket can be cut so that its outside diameter matches the inner edge of the bolts.
  • Dirty or Damaged Flange Faces. Dirt, scale, scratches, protrusions, weld spatter on gasket seating surfaces, and warped seating surfaces provide leakage paths or can cause uneven gasket compression that can result in flange leakage.
  • Excessive Piping System Loads at Flange Locations. Excessive forces and bending moments can loosen the bolting or distort the flanges and lead to leaks. Common causes are inadequate piping flexibility, using cold spring to align flanges, and improper location of supports or restraints.
  • Thermal Shock. Rapid temperature fluctuations can cause flanges to deform temporarily. This is typically a greater potential problem in high temperature applications. Process variations cannot always be avoided. A related problem is temperature variation around the flange circumference (e.g., cooling on top due to rain, or cool liquid at the bottom and hot gas at the top). Where this is a problem, sheet metal shields can be installed to protect against rain or snow impingement that could cause thermal gradients across the flange and cause leakage. Such shields also serve to keep the flanges and bolts at a more uniform temperature.
  • Improper Gasket Size or Material. Sometimes, the wrong gasket size or material is installed. The wrong size should be fairly obvious during installation, and something that a trained boltup crew will immediately identify. The wrong material may not be apparent until corrosion or blowout damages the gasket.
  • Improper Flange Facing. Deeper serrations than specified will prevent the seating of double jacketed or spiral wound gaskets and provide a leakage path. Normal raised face flange finishes have grooves that are 0.002 to 0.005 in. (0.05 to 0.13 mm) deep.
  • High Vibration Levels. Excessive vibration can loosen flange bolts and ultimately cause flange leakage.

So What are the benefits of the Immediate Leak Detection?

When the Leak Detection and Repair requirements were developed, it is estimated that petroleum refineries could reduce emissions from equipment leaks by 63% by implementing a facility Leak Detection and Repair program. Additionally, it is estimated that chemical facilities could reduce VOC emissions by 56% by implementing such a program.

Emissions reductions from implementing an Leak Detection and Repair program potentially reduce product losses, increase safety for workers and operators, decrease exposure of the surrounding community, reduce emissions fees, and help facilities avoid enforcement actions.

1.     Reducing Product Losses

In the petrochemical industry, saleable products are lost whenever emissions escape from process equipment. Lost product generally translates into lost revenue.

2.     Increasing Safety for Facility Workers and Operators

Many of the compounds emitted from refineries and chemical facilities may pose a hazard to exposed workers and operators. Reducing emissions from leaking equipment has the direct benefit of reducing occupational exposure to hazardous compounds.

3.     Decreasing Exposure for the Surrounding Community

In addition to workers and operators at a facility, the population of a surrounding community can be affected by severe, long-term exposure to toxic air pollutants as a result of leaking equipment. Although most of the community exposure may be episodic, chronic health effects can result from long-term exposure to emissions from leaking equipment that is either not identified as leaking or not repaired.

4.     Potentially Reducing Emission Fees

To fund permitting programs, some states and local air pollution districts charge annual fees that are based on total facility emissions. A facility with an effective program for reducing leaking equipment can potentially decrease the amount of these annual fees.

5.     Avoiding Enforcement Actions

In setting Compliance and Enforcement National Priorities for Air Toxics, U.S Environmental Protection Agency has identified Leak Detection programs as a national focus. Therefore, facilities can expect an increased number and frequency of compliance inspections and a closer review of compliance reports submitted to permitting authorities in an effort by the Agency to assess Leak Detection programs and identify potential Leak problems. A facility with an effective Leak Detection program decreases the chances of being targeted for enforcement actions and avoids the costs and penalties associated with rule violations


 


Mike Ames

President Corrground Consulting LLC

5y

I have another. Cathodic current internal transfer in water across an isolation kit.

Adnan A.

PreCom/Commissioning Engineer,QA/QC Sr welding inspector,HydroTest Engineer,Sr Mech Engineer looking for new challenges

5y

over load is more causes

Like
Reply

Good information

Like
Reply
Ahmed Abbas

Senior Rotating Equipment Engineer | Oil & Gas & Power Generation Specialist | Maintenance & Reliability Expert | Certified Machinery Lubrication & Vibration Analyst

5y

Regarding Uneven Bolt Stress, how could i ensure proper tighening ? ( sequance and tightening torque )

Like
Reply
John Arnesen

Sales and Business Development Manager at TP-Products AS

5y

Why not use TPC Compact Flanges? They don’t leak and no maintenance required

To view or add a comment, sign in

More articles by Muhamad Rizky Suhandika

  • Common causes of Piping System Vibration

    Common causes of Piping System Vibration

    Piping vibration problems are real at onshore or offshore production facilities, pipeline stations, refineries, and…

    5 Comments
  • Common Compliance Problems Found With Leak Detection Program

    Common Compliance Problems Found With Leak Detection Program

    Many regulatory agencies determine the compliance status of Leak Detection programs based on a review of submitted…

  • Insight about Leak and Repair

    Insight about Leak and Repair

    When your equipment fails to perform its task especially when it leaks, you need to figure out what is going on…

  • 3 Keys to Improved Bolted Flange Joint Integrity

    3 Keys to Improved Bolted Flange Joint Integrity

    In 2008, Pumps & Systems magazine published an article by Garlit Sealing Technologies, which sees 100 failed gas…

    1 Comment
  • F.L.U.S.H For Successful Oil Flushing

    F.L.U.S.H For Successful Oil Flushing

    F for Full realization and understanding Realizing that most commissioning groups and maintenance personnel are not oil…

Insights from the community

Others also viewed

Explore topics