Generating Nitrogen using Membrane Technology

Generating Nitrogen using Membrane Technology

Producing your own nitrogen means being in full control of your N2 supply. If your company needs nitrogen regularly, this could be a viable option. Besides installing a big cryogenic air separation plant, there are two ways of generating nitrogen yourself: using membrane generators and PSA generators.


Membrane nitrogen generators are based on a simple working principle. The main part of a membrane generator is the membrane module (+- 10cm in diameter), filled with small, hollow polymer fibers. First, dry, clean compressed air enters and due to the structure of these fibers parts of the air will flow to the outside of the fiber. This process is called permeation. During this process, water, oxygen and some of the argon exit through the membrane sides of the fibers. In the end, only nitrogen will remain. This is possible since different molecules permeate at different speeds. H2O will permeate very quickly, oxygen takes a little longer. Argon and Nitrogen permeate rather slowly, meaning that they will remain in the fibers long after the H2O and oxygen are gone (some of the Argon will permeate as well, but it would be inefficient to completely remove it from the air stream). Because of the permeation through the fiber wall, an overpressure would occur inside the membrane housing. The fibers would clog and the permeation efficiency would be significantly lowered. To prevent that from happening there is an opening in the housing, the permeate vent, where these 'exhaust' gases (including H2O, oxygen and Argon) can escape.

It is very important for the intake air to be clean and dry before it enters the membrane. If this is not the case, the shallow fibers will quickly clog. In order to prevent this from happening, correct air treatment of the feed air has to be installed. In some cases the needed filters and dryers will already be built into the generator itself. This would mean that, in some cases, no additional filters should be installed between the compressor and generator. The fibers of the membrane can handle water vapor without much problems. It is however very important that the air doesn't contain liquid water, since this will have a detrimental impact on the membrane. Therefore, it is required for a good water separation solution to be in place upstream the generator, a refrigerant dryer for example. Taking care of the intake air of the generator will protect the membrane and ensure a long lifetime. Take a look at a typical installation below.


for more information and inquires please contact

My email : chemical.technology@hotmail.com

WhatsApp : +201288849001

No alt text provided for this image
No alt text provided for this image

 


jack Hu

cryogenic oxygen plant,lng plant

3y

lox liquid oxygen complete plant manufacture .i am jackhu

Like
Reply

To view or add a comment, sign in

Insights from the community

Others also viewed

Explore topics