CLJ-DS35 REV 0
PRODUCT FAMILY DATA SHEET
Cree
®
J Series™ 2835 18-V LEDs
PRODUCT DESCRIPTION
J Series™ LEDs extend Cree’s industry‑leading portfolio of
lighting‑class LEDs to a broader set of applications. J Series
2835 18‑V LEDs combine high efficacy and excellent value in a
reliable package. J Series 2835 18‑V LEDs enable lower system
costs for low‑density lighting applications where high efficiency
and smooth appearance are critical.
Applications:
•
Indoor lighting such as replacement lamps
•
Downlights
•
High/low‑bays
FEATURES
•
•
•
•
•
•
•
•
Industry‑compatible size : 2.8 x 3.5 x 0.7 mm
18‑V configuration
Flux binned at 25 °C, chromaticity binned at 85 °C
6500 K–2700 K ANSI CCTs available
70, 80 & 90 CRI available for all CCTs
2200 K available for 80 & 90 CRI
RoHS compliant
UL
®
recognized component (E495478)
PRODUCT SUMMARY
Product
JK2835 18‑V
Power
Class
1.0 W
Test
Temperature
25
°C
Test
Current
50 mA
Typical
Forward
Voltage
18.2 V
4000 K, 70 CRI
Typical Flux
139 lm
Typical Efficacy
153 LPW
3000 K, 80 CRI
Typical Flux
125 lm
Typical Efficacy
137 LPW
Maximum
Current
60 mA
WWW.CREE.COM/JSERIES
J Series™ Products are sold exclusively by Cree Venture LED Company Limited (“Cree Venture”), regardless of geography. Any orders for
J Series Products that are submitted to Cree, Inc. or any of its other subsidiaries will be directed to Cree Venture for acknowledgement
and order fulfillment.
Copyright © 2019 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree
®
and the Cree logo are
registered trademarks and J Series™ is a trademark of Cree, Inc. UL
®
and the UR logo are registered trademarks of UL LLC. J Series products are
marketed by Cree, Inc. for the benefit of Cree Venture LED Company Limited.
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
J SERIES™ 2835 18-V LED
TABLE OF CONTENTS
Order Code & Bin Code Formats
........................................................................................................................................................................... 3
Characteristics
.......................................................................................................................................................................................................
4
Operating Limits
.....................................................................................................................................................................................................
4
Flux Characteristics, Order Codes and Bins
......................................................................................................................................................... 5
Relative Luminous Flux vs. Current
....................................................................................................................................................................... 6
Electrical Characteristics
....................................................................................................................................................................................... 6
Relative Chromaticity vs. Current
..........................................................................................................................................................................
7
Relative Chromaticity vs. Temperature
.................................................................................................................................................................
7
Relative Spectral Power Distribution
.................................................................................................................................................................... 8
Relative Luminous Flux vs. Junction Temperature
..............................................................................................................................................
9
Typical Spatial Distribution
....................................................................................................................................................................................
9
Performance Groups ‑ Luminous Flux
................................................................................................................................................................ 10
Performance Groups ‑ Forward Voltage
............................................................................................................................................................. 10
Performance Groups ‑ Chromaticity
................................................................................................................................................................... 11
Reflow Soldering Characteristics
........................................................................................................................................................................ 21
Notes
.................................................................................................................................................................................................................... 22
Mechanical Dimensions
......................................................................................................................................................................................
24
Tape & Reel
........................................................................................................................................................................................................... 25
Packaging
.............................................................................................................................................................................................................
27
Copyright © 2019 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree
®
and the Cree logo are registered trademarks and J Series™ is a trademark of Cree,
Inc. UL
®
and the UR logo are registered trademarks of UL LLC. J Series products are marketed by Cree, Inc. for the benefit of Cree Venture LED Company Limited.
2
J SERIES™ 2835 18-V LED
ORDER CODE & BIN CODE FORMATS
Order codes and bin codes for J Series 2835 18‑V LEDs are configured in the following manner:
Order Code
Series
J = J Series
Family name
2835
Color
WT = White
Forward voltage class
Bin Code
Series
J = J Series
Family name
2835
Color
WT = White
Chromaticity bin
Forward voltage bin
Internal code
Flux group
JPSSSSXCC-BB-DDDD-DDDVVYFFWWW
Chromaticity group
CRI specification
B = 70 CRI minimum
H = 80 CRI minimum
U = 90 CRI minimum
Internal code
Version
JPSSSSXCC-B-WWW-FFF-VV-Y-DD
CRI specification
B = 70 CRI minimum
H = 80 CRI minimum
U = 90 CRI minimum
Flux group
Internal code
Version
Power class
K = 1.0 W
Power class
K = 1.0 W
Copyright © 2019 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree
®
and the Cree logo are registered trademarks and J Series™ is a trademark of Cree,
Inc. UL
®
and the UR logo are registered trademarks of UL LLC. J Series products are marketed by Cree, Inc. for the benefit of Cree Venture LED Company Limited.
3
J SERIES™ 2835 18-V LED
CHARACTERISTICS
Characteristics
Thermal resistance, junction to solder point
Viewing angle (FWHM)
Temperature coefficient of voltage
ESD withstand voltage (JEDEC JS‑001‑2012)
DC forward current
Reverse voltage
Forward voltage (@ 50 mA, 25 °C)
LED junction temperature
Operating temperature
mA
V
V
°C
°C
‑40
18.2
Unit
°C/W
degrees
mV/°C
Minimum
Typical
15
120
‑9.6
Class 2
60
5
20
125
105
Maximum
OPERATING LIMITS
The maximum forward current is determined by the thermal resistance between the LED junction and ambient.
70
Operating Limits
60
92 °C, 60 mA
Forward Current (mA)
50
40
Rj-a = 30 °C/W
105 °C,
37 mA
30
20
10
0
0
20
40
60
80
100
120
Ambient Temperature (°C)
data from 180519 FLO 2835 18V BOM B Datasheet final dhh jlc-operating limits.xlsx
Copyright © 2019 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree
®
and the Cree logo are registered trademarks and J Series™ is a trademark of Cree,
Inc. UL
®
and the UR logo are registered trademarks of UL LLC. J Series products are marketed by Cree, Inc. for the benefit of Cree Venture LED Company Limited.
4
J SERIES™ 2835 18-V LED
FLUX CHARACTERISTICS, ORDER CODES AND BINS (I
F
= 50 mA, T
j
= 25 °C)
The following table provides order codes for J Series 2835 18‑V LEDs. For a complete description of the order code nomenclature, please
see the Order Code and Bin Code Formats section (page 3). For definitions of the chromaticity kits, please see the Performance
Groups ‑ Chromaticity section (page 11).
Nominal
CCT
Minimum
CRI
◊
70
6500 K
80
90
70
5700 K
80
90
70
5000 K
80
90
70
4500 K
80
90
70
4000 K
80
90
70
3500 K
80
90
70
3000 K
80
90
70
2700 K
80
90
2200 K
80
90
Flux
Group
M2
L4
J2
M2
L4
J2
M2
L4
J2
M2
L4
J2
M2
L4
J2
L4
L2
J2
L2
K4
H4
K4
K2
H2
H4
G2
Minimum
Flux (lm)
@ 25 °C
130
125
100
130
125
100
130
125
100
130
125
100
130
125
100
125
120
100
120
115
95
115
110
90
95
80
Typical
Flux (lm)
@ 25 °C
139
132
112
139
132
112
139
132
112
139
132
112
139
132
112
135
129
109
132
125
106
127
120
102
101
86
Typical
Flux (lm)
@ 85 °C*
123
117
99
123
117
99
123
117
99
123
117
99
123
117
99
119
114
96
117
111
94
112
106
90
89
76
Order Code
JK2835AWT‑00‑0000‑000F0BM265E
JK2835AWT‑00‑0000‑000F0HL465E
JK2835AWT‑00‑0000‑000F0UJ265E
JK2835AWT‑00‑0000‑000F0BM257E
JK2835AWT‑00‑0000‑000F0HL457E
JK2835AWT‑00‑0000‑000F0UJ257E
JK2835AWT‑00‑0000‑000F0BM250E
JK2835AWT‑00‑0000‑000F0HL450E
JK2835AWT‑00‑0000‑000F0UJ250E
JK2835AWT‑00‑0000‑000F0BM245E
JK2835AWT‑00‑0000‑000F0HL445E
JK2835AWT‑00‑0000‑000F0UJ245E
JK2835AWT‑00‑0000‑000F0BM240E
JK2835AWT‑00‑0000‑000F0HL440E
JK2835AWT‑00‑0000‑000F0UJ240E
JK2835AWT‑00‑0000‑000F0BL435E
JK2835AWT‑00‑0000‑000F0HL235E
JK2835AWT‑00‑0000‑000F0UJ235E
JK2835AWT‑00‑0000‑000F0BL230E
JK2835AWT‑00‑0000‑000F0HK430E
JK2835AWT‑00‑0000‑000F0UH430E
JK2835AWT‑00‑0000‑000F0BK427E
JK2835AWT‑00‑0000‑000F0HK227E
JK2835AWT‑00‑0000‑000F0UH227E
JK2835AWT‑00‑0000‑000F0HH422E
JK2835AWT‑00‑0000‑000F0UG222E
Notes:
•
Cree Venture maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and
±2 on CRI measurements. See the Measurements section (page 22).
•
Cree Venture J Series 2835 18‑V LED order codes specify only a minimum flux bin and not a maximum. Cree Venture may ship
reels in flux bins higher than the minimum specified by the order code without advance notice. Shipments will always adhere to the
chromaticity restrictions specified by the order code.
◊ CRI R9 minimum is 0 for 80 CRI minimum LEDs and 50 for 90 CRI minimum LEDs, with a ±3 tolerance.
*
Flux values @ 85 °C are calculated and for reference only.
Copyright © 2019 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree
®
and the Cree logo are registered trademarks and J Series™ is a trademark of Cree,
Inc. UL
®
and the UR logo are registered trademarks of UL LLC. J Series products are marketed by Cree, Inc. for the benefit of Cree Venture LED Company Limited.
5