Personal dosimetry TLD 100 in orthopedic surgeons exposed to ionizing radiation in Bogota - Colombia
Sierra C, B. Y.; Jimenez, Y.; Plazas, M. C.; Eslava S, J.; Groot R, H., E-mail: brigith.sierra@gmail.com
Sociedad Peruana de Radioproteccion, Lima (Peru); Sociedad Mexicana de Irradiacion y Dosimetria, Mexico D. F. (Mexico). Funding organisation: Organizacion Panamericana de la Salud, Washington D. C. (United States); Universidad Nacional de San Antonio de Abad del Cusco, Cusco (Peru); Instituto Peruano de Energia Nuclear, Lima (Peru); Elekta AB (Sweden); RadPro International GmbH (Germany); ThermoFisher Scientific, Inc. (United States); Varian Medical Systems (United States)2014
Sociedad Peruana de Radioproteccion, Lima (Peru); Sociedad Mexicana de Irradiacion y Dosimetria, Mexico D. F. (Mexico). Funding organisation: Organizacion Panamericana de la Salud, Washington D. C. (United States); Universidad Nacional de San Antonio de Abad del Cusco, Cusco (Peru); Instituto Peruano de Energia Nuclear, Lima (Peru); Elekta AB (Sweden); RadPro International GmbH (Germany); ThermoFisher Scientific, Inc. (United States); Varian Medical Systems (United States)2014
AbstractAbstract
[en] Orthopedic surgeons should be considered as professionals occupationally exposed to ionizing radiation, for using C arc (fluoroscope) an equipment of X type radiation emission, during surgical procedures for imaging generation. Some health institutes, use of C arc under uncontrolled circumstances, such a lack of dosimetry control, incomplete or absence of personnel protective elements and protective measures, which in turn, lead to a high exposition to the personnel. Materials and methods. Study of double match cohort by age and gender, was conducted, in four health institutions of second and third level of attention in Bogota city. Personal dosimetry measurements with TLD-100 dosimetry crystals in both cohorts and environmental dosimetry in each of operation rooms used for orthopedic procedures, were carry out during six months of follow up. Dosimetry crystals were read in a Harshaw 4500 - Bicron equipment, in the Medical Physics Laboratory of National University of Colombia. Results. Dosimetry measurements are compatibles with those of occupationally exposed personnel 3.44 mSv/6 m CI 95% (1.66-3.99), even does not overpass ICRP recommendations, are higher as were expect at the beginning of the study. The median of effective accumulative dose in thorax is 3,4 mSv CI 95% (1,66-3,99), higher in comparison with neck value 2,7 mSv CI 95% (1,73-3,80) and hand dosimetry 1,42 mSv CI 95% (0,96-2,34). Conclusions: Orthopedic surgeons should be considered occupational exposed to ionizing radiation, who has to accomplish to the radiological protection measures, dosimetric follow up and maintenance of the used X ray equipment. It was confirm throughout this study that dosimetry shows higher levels as expected at the beginning of the study, compatible with occupationally exposed personnel. (Author)
Original Title
Dosimetria personal TLD 110 en medicos ortopedistas expuestos a radiacion ionizante en Bogota - Colombia
Primary Subject
Source
Aug 2014; 17 p; Sociedad Mexicana de Irradiacion y Dosimetria; Mexico, D. F. (Mexico); 14. International Symposium on Solid State Dosimetry; 14. Conferencia Internacional sobre Dosimetria de Estado Solido; Cusco (Peru); 13-16 Apr 2014
Record Type
Miscellaneous
Literature Type
Conference
Report Number
Country of publication
Reference NumberReference Number
INIS VolumeINIS Volume
INIS IssueINIS Issue